The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water

碩士 === 中原大學 === 生物醫學工程研究所 === 99 === Abstract Chlorine/chloramine residues in water have a considerable threat to hemodialysis patients. According to relevant literature, chlorine/chloramine residues in water are related to the hemolysis phenomenon during the treatment of dialysis patients. I...

Full description

Bibliographic Details
Main Authors: Zhi-Da Wang, 王子達
Other Authors: Yen-Lin Chang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/48253110144617154353
id ndltd-TW-099CYCU5114029
record_format oai_dc
spelling ndltd-TW-099CYCU51140292015-10-13T20:52:04Z http://ndltd.ncl.edu.tw/handle/48253110144617154353 The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water 活性碳等溫吸附與吸附床設計應用於血液透析用水中餘氯移除之探討 Zhi-Da Wang 王子達 碩士 中原大學 生物醫學工程研究所 99 Abstract Chlorine/chloramine residues in water have a considerable threat to hemodialysis patients. According to relevant literature, chlorine/chloramine residues in water are related to the hemolysis phenomenon during the treatment of dialysis patients. In addition, among all the water treatment procedures of dialysis, only the activated carbon adsorption procedure can effectively eliminate chlorine/chloramine residues in water to reduce the hemolysis phenomenon of dialysis patients. The purpose of this study is to estimate the breakthrough time and filling height of the activated carbon adsorption bed by the mathematical models of the isotherm adsorption and fixed bed adsorption theories, in order to effectively remove the chlorine/chloramine residues in water and reduce the occurrence of hemolysis phenomenon of the dialysis patients during dialysis. This study conducted three types of tests using the clinically used activated carbon adsorbents. The first type test was the adsorption speed test using a fixed amount of activated carbon; the secondary test was the isotherm adsorption test of using different amounts of activated carbon in sodium hypochlorite solution of given volume, and conducted regression analysis and relevant analysis of the adsorption results to find the appropriate isotherm adsorption model; the third type of test was the fixed bed adsorption simulation test with carbon adsorption device of scaled dwon specifications for clinical use, and the adsorption results were analyzed using the fixed bed adsorption mathematical theoretical model. The results suggested that the clinically used activated adsorbents can effectively reduce the chlorine/chloramine residues in water in 5 min, and completely eliminate them in 15 min. The regression analysis of the isotherm adsorption testing results found that the clinically used activated carbon adsorbent can facilitate adsorption with the adsorption index (1/n) at 0.52. A comparison with the relevant analysis results of Langmuir and Freundlich found that the adsorbent can better fit the Freundlich isotherm adsorption model with correlation coefficient at 0.91. The fixed bed adsorption simulation results suggested that the breakthrough time of the column adsorption were 13 hr and the saturated adsorption time was 21 hr. By the mathematical model of the fixed bed adsorption theory, the column adsorption belt (δ) was 0.02 m, and the column adsorption belt moving speed (ν) was 3.04 x 10-3(m/hr), number of moving units (Nf) was 3.61 and the total capacity (Kfav) was 9925.23(1/hr). By inputting different theoretical solution concentrations into the theoretical mathematical model, it was confirmed by calculation that the theoretical adsorption time and testing time of the model have good correlation. The relevant parameters of the clinically used carbon adsorption device were input into the theoretical mathematical model to obtain the theoretical filling bed height (Z) of theoretical scaling up as 0.87 m, which was a gap of 0.13 m from the filling height bed height of 1 m, as provided by the manufacturer. The theoretical breakthrough time was 8760 hr, which was consistent with the manufacturer-suggested replacement time. By isotherm adsorption test and the fixed bed adsorption theoretical mathematical model, the breakthrough time and filling height of the activated carbon filling bed can be estimated to effectively eliminate the chlorine/chloramine residues in water to reduce the occurrence of hemolysis phenomenon of dialysis patients during dialysis. Yen-Lin Chang 張炎林 2011 學位論文 ; thesis 92 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 生物醫學工程研究所 === 99 === Abstract Chlorine/chloramine residues in water have a considerable threat to hemodialysis patients. According to relevant literature, chlorine/chloramine residues in water are related to the hemolysis phenomenon during the treatment of dialysis patients. In addition, among all the water treatment procedures of dialysis, only the activated carbon adsorption procedure can effectively eliminate chlorine/chloramine residues in water to reduce the hemolysis phenomenon of dialysis patients. The purpose of this study is to estimate the breakthrough time and filling height of the activated carbon adsorption bed by the mathematical models of the isotherm adsorption and fixed bed adsorption theories, in order to effectively remove the chlorine/chloramine residues in water and reduce the occurrence of hemolysis phenomenon of the dialysis patients during dialysis. This study conducted three types of tests using the clinically used activated carbon adsorbents. The first type test was the adsorption speed test using a fixed amount of activated carbon; the secondary test was the isotherm adsorption test of using different amounts of activated carbon in sodium hypochlorite solution of given volume, and conducted regression analysis and relevant analysis of the adsorption results to find the appropriate isotherm adsorption model; the third type of test was the fixed bed adsorption simulation test with carbon adsorption device of scaled dwon specifications for clinical use, and the adsorption results were analyzed using the fixed bed adsorption mathematical theoretical model. The results suggested that the clinically used activated adsorbents can effectively reduce the chlorine/chloramine residues in water in 5 min, and completely eliminate them in 15 min. The regression analysis of the isotherm adsorption testing results found that the clinically used activated carbon adsorbent can facilitate adsorption with the adsorption index (1/n) at 0.52. A comparison with the relevant analysis results of Langmuir and Freundlich found that the adsorbent can better fit the Freundlich isotherm adsorption model with correlation coefficient at 0.91. The fixed bed adsorption simulation results suggested that the breakthrough time of the column adsorption were 13 hr and the saturated adsorption time was 21 hr. By the mathematical model of the fixed bed adsorption theory, the column adsorption belt (δ) was 0.02 m, and the column adsorption belt moving speed (ν) was 3.04 x 10-3(m/hr), number of moving units (Nf) was 3.61 and the total capacity (Kfav) was 9925.23(1/hr). By inputting different theoretical solution concentrations into the theoretical mathematical model, it was confirmed by calculation that the theoretical adsorption time and testing time of the model have good correlation. The relevant parameters of the clinically used carbon adsorption device were input into the theoretical mathematical model to obtain the theoretical filling bed height (Z) of theoretical scaling up as 0.87 m, which was a gap of 0.13 m from the filling height bed height of 1 m, as provided by the manufacturer. The theoretical breakthrough time was 8760 hr, which was consistent with the manufacturer-suggested replacement time. By isotherm adsorption test and the fixed bed adsorption theoretical mathematical model, the breakthrough time and filling height of the activated carbon filling bed can be estimated to effectively eliminate the chlorine/chloramine residues in water to reduce the occurrence of hemolysis phenomenon of dialysis patients during dialysis.
author2 Yen-Lin Chang
author_facet Yen-Lin Chang
Zhi-Da Wang
王子達
author Zhi-Da Wang
王子達
spellingShingle Zhi-Da Wang
王子達
The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
author_sort Zhi-Da Wang
title The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
title_short The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
title_full The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
title_fullStr The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
title_full_unstemmed The granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis Water
title_sort granular activated carbon adsorption isothermal and adsorption bed design application to remove chlorine in hemodialysis water
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/48253110144617154353
work_keys_str_mv AT zhidawang thegranularactivatedcarbonadsorptionisothermalandadsorptionbeddesignapplicationtoremovechlorineinhemodialysiswater
AT wángzidá thegranularactivatedcarbonadsorptionisothermalandadsorptionbeddesignapplicationtoremovechlorineinhemodialysiswater
AT zhidawang huóxìngtànděngwēnxīfùyǔxīfùchuángshèjìyīngyòngyúxuèyètòuxīyòngshuǐzhōngyúlǜyíchúzhītàntǎo
AT wángzidá huóxìngtànděngwēnxīfùyǔxīfùchuángshèjìyīngyòngyúxuèyètòuxīyòngshuǐzhōngyúlǜyíchúzhītàntǎo
AT zhidawang granularactivatedcarbonadsorptionisothermalandadsorptionbeddesignapplicationtoremovechlorineinhemodialysiswater
AT wángzidá granularactivatedcarbonadsorptionisothermalandadsorptionbeddesignapplicationtoremovechlorineinhemodialysiswater
_version_ 1718053037422936064