Performance Study of a Beam Monitoring System for Proton Therapy

碩士 === 國立中央大學 === 物理研究所 === 99 === Proton therapy facilities will be in operation in Taiwan in few years. It is important to have a reliable beam monitoring system for daily operation. A prototype 16-channel strip ionization chamber with custom-design readout electronics and a multi-layer Faraday cu...

Full description

Bibliographic Details
Main Authors: Shu-Jhen Dai, 戴淑眞
Other Authors: Willis T. Lin
Format: Others
Language:en_US
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/13831110060089681366
id ndltd-TW-099NCU05198029
record_format oai_dc
spelling ndltd-TW-099NCU051980292017-07-08T16:28:25Z http://ndltd.ncl.edu.tw/handle/13831110060089681366 Performance Study of a Beam Monitoring System for Proton Therapy 應用於質子治療之射束監測系統的特性研究 Shu-Jhen Dai 戴淑眞 碩士 國立中央大學 物理研究所 99 Proton therapy facilities will be in operation in Taiwan in few years. It is important to have a reliable beam monitoring system for daily operation. A prototype 16-channel strip ionization chamber with custom-design readout electronics and a multi-layer Faraday cup have been developed for this purpose. In this study, three aims are measuring the depth-dose distribution, beam profile and beam energy. The characteristics and performance of the ionization chamber have been studied using the beam at the Institute of Nuclear Energy Research (INER) and the Cyclotron and Radioisotope Center (CYRIC) of Tohoku University. The depth-dose distributions (Bragg curve) of protons in Acrylonitrile Butadiene Styrene (ABS) are obtained and the results agree with the Geant4 simulation well. Beam spread with depth is measured. The quasi 3-D beam profile with 80 MeV proton beam at CYRIC are measured by six ionization chambers arranged in X- and Y-direction alternatively. Beam energy used at CYRIC is measured with the multi-layer Faraday cup (MLFC). A set of beam energy and its spread, by passing the beam through copper block with various thicknesses, is measured with the MLFC. The method of maximum likelihood is used to fit the data with the GEANT4 simulation. The best result obtained is 77.8 ± 0.1 MeV, which agrees well with the NMR probe measurement. Willis T. Lin 林宗泰 2011 學位論文 ; thesis 69 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 物理研究所 === 99 === Proton therapy facilities will be in operation in Taiwan in few years. It is important to have a reliable beam monitoring system for daily operation. A prototype 16-channel strip ionization chamber with custom-design readout electronics and a multi-layer Faraday cup have been developed for this purpose. In this study, three aims are measuring the depth-dose distribution, beam profile and beam energy. The characteristics and performance of the ionization chamber have been studied using the beam at the Institute of Nuclear Energy Research (INER) and the Cyclotron and Radioisotope Center (CYRIC) of Tohoku University. The depth-dose distributions (Bragg curve) of protons in Acrylonitrile Butadiene Styrene (ABS) are obtained and the results agree with the Geant4 simulation well. Beam spread with depth is measured. The quasi 3-D beam profile with 80 MeV proton beam at CYRIC are measured by six ionization chambers arranged in X- and Y-direction alternatively. Beam energy used at CYRIC is measured with the multi-layer Faraday cup (MLFC). A set of beam energy and its spread, by passing the beam through copper block with various thicknesses, is measured with the MLFC. The method of maximum likelihood is used to fit the data with the GEANT4 simulation. The best result obtained is 77.8 ± 0.1 MeV, which agrees well with the NMR probe measurement.
author2 Willis T. Lin
author_facet Willis T. Lin
Shu-Jhen Dai
戴淑眞
author Shu-Jhen Dai
戴淑眞
spellingShingle Shu-Jhen Dai
戴淑眞
Performance Study of a Beam Monitoring System for Proton Therapy
author_sort Shu-Jhen Dai
title Performance Study of a Beam Monitoring System for Proton Therapy
title_short Performance Study of a Beam Monitoring System for Proton Therapy
title_full Performance Study of a Beam Monitoring System for Proton Therapy
title_fullStr Performance Study of a Beam Monitoring System for Proton Therapy
title_full_unstemmed Performance Study of a Beam Monitoring System for Proton Therapy
title_sort performance study of a beam monitoring system for proton therapy
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/13831110060089681366
work_keys_str_mv AT shujhendai performancestudyofabeammonitoringsystemforprotontherapy
AT dàishūzhēn performancestudyofabeammonitoringsystemforprotontherapy
AT shujhendai yīngyòngyúzhìzizhìliáozhīshèshùjiāncèxìtǒngdetèxìngyánjiū
AT dàishūzhēn yīngyòngyúzhìzizhìliáozhīshèshùjiāncèxìtǒngdetèxìngyánjiū
_version_ 1718493960738963456