Study of a small-size adsorption cooling system

碩士 === 國立中央大學 === 能源工程研究所 === 99 === In this study, a silica gel-water adsorption system is designed and the system performance is measured. Two different adsorption beds and two different condensers are tested in the experiment. One adsorption bed is made by 3mm diameter copper tubes and the thickn...

Full description

Bibliographic Details
Main Authors: Chun-Lei Chang, 張鈞磊
Other Authors: Chien-Yuh Yang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/76591072752449291182
id ndltd-TW-099NCU05399009
record_format oai_dc
spelling ndltd-TW-099NCU053990092017-07-09T04:29:51Z http://ndltd.ncl.edu.tw/handle/76591072752449291182 Study of a small-size adsorption cooling system 小型吸附式空調系統研究 Chun-Lei Chang 張鈞磊 碩士 國立中央大學 能源工程研究所 99 In this study, a silica gel-water adsorption system is designed and the system performance is measured. Two different adsorption beds and two different condensers are tested in the experiment. One adsorption bed is made by 3mm diameter copper tubes and the thickness of coated silica gel is 2mm. The silica gel weight of copper-tubes adsorption bed is 0.8 kg. Another adsorption bed is made by flat-tube heat exchanger whose volume and thickness of silica gel are the same as copper-tube adsorption bed. The weight of silica gel is 1.46 kg. The first condenser is a copper tube heat exchanger; another is a fin-tube heat exchanger. In experimental condition, there are two different temperatures of hot water, 75 and 80℃; two different temperatures of cooling water, 25 and 30℃. The temperature of cold water is 20℃. The cycle time are 6、12 and 20 minutes in copper-tube adsorption bed experiment. And in flat-tube adsorption bed experiment, the cycle time are 20、30 and 40 minutes. The result shows that the copper-tube adsorption bed doesn’t refrigerate the water of evaporator. It is because that the cooling power of copper-tube adsorption bed is not enough to cool the heat capability of total vacuumed chamber. And it also indicates that the higher temperature of hot water、the lower temperature of cooling water and the longer cycle time, the COP(coefficient of performance) of flat-tube adsorption bed is higher. And COP doesn’t increase by replacing the copper-tube condenser to fin-tube condenser. Chien-Yuh Yang 楊建裕 2011 學位論文 ; thesis 125 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 能源工程研究所 === 99 === In this study, a silica gel-water adsorption system is designed and the system performance is measured. Two different adsorption beds and two different condensers are tested in the experiment. One adsorption bed is made by 3mm diameter copper tubes and the thickness of coated silica gel is 2mm. The silica gel weight of copper-tubes adsorption bed is 0.8 kg. Another adsorption bed is made by flat-tube heat exchanger whose volume and thickness of silica gel are the same as copper-tube adsorption bed. The weight of silica gel is 1.46 kg. The first condenser is a copper tube heat exchanger; another is a fin-tube heat exchanger. In experimental condition, there are two different temperatures of hot water, 75 and 80℃; two different temperatures of cooling water, 25 and 30℃. The temperature of cold water is 20℃. The cycle time are 6、12 and 20 minutes in copper-tube adsorption bed experiment. And in flat-tube adsorption bed experiment, the cycle time are 20、30 and 40 minutes. The result shows that the copper-tube adsorption bed doesn’t refrigerate the water of evaporator. It is because that the cooling power of copper-tube adsorption bed is not enough to cool the heat capability of total vacuumed chamber. And it also indicates that the higher temperature of hot water、the lower temperature of cooling water and the longer cycle time, the COP(coefficient of performance) of flat-tube adsorption bed is higher. And COP doesn’t increase by replacing the copper-tube condenser to fin-tube condenser.
author2 Chien-Yuh Yang
author_facet Chien-Yuh Yang
Chun-Lei Chang
張鈞磊
author Chun-Lei Chang
張鈞磊
spellingShingle Chun-Lei Chang
張鈞磊
Study of a small-size adsorption cooling system
author_sort Chun-Lei Chang
title Study of a small-size adsorption cooling system
title_short Study of a small-size adsorption cooling system
title_full Study of a small-size adsorption cooling system
title_fullStr Study of a small-size adsorption cooling system
title_full_unstemmed Study of a small-size adsorption cooling system
title_sort study of a small-size adsorption cooling system
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/76591072752449291182
work_keys_str_mv AT chunleichang studyofasmallsizeadsorptioncoolingsystem
AT zhāngjūnlěi studyofasmallsizeadsorptioncoolingsystem
AT chunleichang xiǎoxíngxīfùshìkōngdiàoxìtǒngyánjiū
AT zhāngjūnlěi xiǎoxíngxīfùshìkōngdiàoxìtǒngyánjiū
_version_ 1718494019909058560