Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis

碩士 === 國立臺灣大學 === 臨床牙醫學研究所 === 99 === Objectives: The stress around implants has been considered to affect the prognosis of implant therapy. The purpose of this study was to evaluate the effects of platform switching on the peri-implant bone strain in dental implants with external and internal conne...

Full description

Bibliographic Details
Main Authors: Yun-Hsuan Huang, 黃韻璇
Other Authors: 林立德
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/83868573516326017422
id ndltd-TW-099NTU05594013
record_format oai_dc
spelling ndltd-TW-099NTU055940132015-10-16T04:02:51Z http://ndltd.ncl.edu.tw/handle/83868573516326017422 Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis 外接式及內接式牙科植體之不同水平偏移程度平台轉換對於嵴骨區應力改變之影響:利用應變規分析 Yun-Hsuan Huang 黃韻璇 碩士 國立臺灣大學 臨床牙醫學研究所 99 Objectives: The stress around implants has been considered to affect the prognosis of implant therapy. The purpose of this study was to evaluate the effects of platform switching on the peri-implant bone strain in dental implants with external and internal connections, with strain gauge technique, under three different loads: the central vertical load, the lingual vertical load, the horizontal load. The other purpose was to evaluate whether increasing the degree of horizontal offset resulted in decreasing the peri-implant bone strain. Methods: Four types of implant:external hex connection and internal hex connection platform implant(OSSEOTITE® Parallel Walled Implants, BIOMET 3i, Palm Beach Gardens,USA), length 13㎜ with different diameter 5.0 ㎜, 6.0 ㎜, were embedded in a 20 x 22 x 70 mm (width x height x length) epoxy resin block. Four strain gauges (EA-00-031CE-350) were bonded on resin surface adjacent to the buccal, mesial , lingual , and distal side of the implant platform. A CAD-CAM 10 x 10 x 11.5 ㎜ (width x length x height) tetragonal column customized abutments was fabricated. Three types of load were applied (vertical loads at two locations:the central vertical load, the lingual vertical load, and a horizontal load) with three different intensities (10N, 30 N and 50N). Each load was repeated 10 times and the data from the strain gauge were recorded and analyzed. Results: 1. Under the central vertical load, the platform switching design did not change peri-implant bone strain tendancy significantly. 2. Under the lingual vertical load, there was a tendency that the platform switching design decreased peri-implant bone strain. The greater amount of horizontal shifting, the smaller the peri-implant bone strain. When the applied load was larger, the tendency of reduced bone strain became more statistically significant. 3. Under the horizontal load, the trend was similar to that under lingual vertical load. 4. There was a difference between external hex connection and internal hex connection groups. Under the off-axis load, the reduction percentage of peri-implant bone strain in platform switching group of the internal hex connection group was not as large as that of the external hex connection. Conclusions: The data suggested that under off-axis load, there was a trend that the platform switching design decreased peri-implant bone strain in both external and internal connection groups. The greater amount of horizontal shifting, the smaller the peri-implant bone strain. When the applied load was larger, the tendency become more statistically significant. However, the reduction percentage in peri-implant bone strain in platform switching group of the internal hex connection group was not as large as that of the external hex connection under the off-axis force application. 林立德 2011 學位論文 ; thesis 135 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 臨床牙醫學研究所 === 99 === Objectives: The stress around implants has been considered to affect the prognosis of implant therapy. The purpose of this study was to evaluate the effects of platform switching on the peri-implant bone strain in dental implants with external and internal connections, with strain gauge technique, under three different loads: the central vertical load, the lingual vertical load, the horizontal load. The other purpose was to evaluate whether increasing the degree of horizontal offset resulted in decreasing the peri-implant bone strain. Methods: Four types of implant:external hex connection and internal hex connection platform implant(OSSEOTITE® Parallel Walled Implants, BIOMET 3i, Palm Beach Gardens,USA), length 13㎜ with different diameter 5.0 ㎜, 6.0 ㎜, were embedded in a 20 x 22 x 70 mm (width x height x length) epoxy resin block. Four strain gauges (EA-00-031CE-350) were bonded on resin surface adjacent to the buccal, mesial , lingual , and distal side of the implant platform. A CAD-CAM 10 x 10 x 11.5 ㎜ (width x length x height) tetragonal column customized abutments was fabricated. Three types of load were applied (vertical loads at two locations:the central vertical load, the lingual vertical load, and a horizontal load) with three different intensities (10N, 30 N and 50N). Each load was repeated 10 times and the data from the strain gauge were recorded and analyzed. Results: 1. Under the central vertical load, the platform switching design did not change peri-implant bone strain tendancy significantly. 2. Under the lingual vertical load, there was a tendency that the platform switching design decreased peri-implant bone strain. The greater amount of horizontal shifting, the smaller the peri-implant bone strain. When the applied load was larger, the tendency of reduced bone strain became more statistically significant. 3. Under the horizontal load, the trend was similar to that under lingual vertical load. 4. There was a difference between external hex connection and internal hex connection groups. Under the off-axis load, the reduction percentage of peri-implant bone strain in platform switching group of the internal hex connection group was not as large as that of the external hex connection. Conclusions: The data suggested that under off-axis load, there was a trend that the platform switching design decreased peri-implant bone strain in both external and internal connection groups. The greater amount of horizontal shifting, the smaller the peri-implant bone strain. When the applied load was larger, the tendency become more statistically significant. However, the reduction percentage in peri-implant bone strain in platform switching group of the internal hex connection group was not as large as that of the external hex connection under the off-axis force application.
author2 林立德
author_facet 林立德
Yun-Hsuan Huang
黃韻璇
author Yun-Hsuan Huang
黃韻璇
spellingShingle Yun-Hsuan Huang
黃韻璇
Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
author_sort Yun-Hsuan Huang
title Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
title_short Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
title_full Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
title_fullStr Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
title_full_unstemmed Effects of Different Horizontal Offset Platform Switching on the Crestal Bone Stress in Dental Implants with External and Internal Connections: A Strain Gauge Analysis
title_sort effects of different horizontal offset platform switching on the crestal bone stress in dental implants with external and internal connections: a strain gauge analysis
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/83868573516326017422
work_keys_str_mv AT yunhsuanhuang effectsofdifferenthorizontaloffsetplatformswitchingonthecrestalbonestressindentalimplantswithexternalandinternalconnectionsastraingaugeanalysis
AT huángyùnxuán effectsofdifferenthorizontaloffsetplatformswitchingonthecrestalbonestressindentalimplantswithexternalandinternalconnectionsastraingaugeanalysis
AT yunhsuanhuang wàijiēshìjínèijiēshìyákēzhítǐzhībùtóngshuǐpíngpiānyíchéngdùpíngtáizhuǎnhuànduìyújǐgǔqūyīnglìgǎibiànzhīyǐngxiǎnglìyòngyīngbiànguīfēnxī
AT huángyùnxuán wàijiēshìjínèijiēshìyákēzhítǐzhībùtóngshuǐpíngpiānyíchéngdùpíngtáizhuǎnhuànduìyújǐgǔqūyīnglìgǎibiànzhīyǐngxiǎnglìyòngyīngbiànguīfēnxī
_version_ 1718091591719059456