Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph
碩士 === 聖約翰科技大學 === 自動化及機電整合研究所 === 99 === In this thesis we present the development of a pulse oximeter to estimate continuous blood pressure based on photoplethysmograph and consider its application in home care scenario. In order to accomplish our goal, we combined a sphygmomanometer and a photopl...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/82443781257565730987 |
id |
ndltd-TW-099SJSM0689001 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099SJSM06890012016-04-22T04:23:49Z http://ndltd.ncl.edu.tw/handle/82443781257565730987 Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph 研製基於光體積描繪圖訊號之血氧飽和濃度模組與其應用於連續血壓之推估 Chia-Chun Hong 洪嘉駿 碩士 聖約翰科技大學 自動化及機電整合研究所 99 In this thesis we present the development of a pulse oximeter to estimate continuous blood pressure based on photoplethysmograph and consider its application in home care scenario. In order to accomplish our goal, we combined a sphygmomanometer and a photoplethysmograph module to design a non-invasive blood pressure module which can estimate the continuous blood pressure. First, the Oscillometric Method was used to obtain the diastolic pressure and the systolic pressure of a person. The two parameters are further applied to calibration of the voltage-to-pressure ratio in a photoplethysmograph, which establishes the physiological parameter specific to each person. Second, not only to calculate the SPO2, our pulse oximeter can also measure the value of the continuous blood pressure and the heart rate in a non-invasive way. The pulse oximeter can display real-time results and store the information into a computer, allowing diagnostic reference for doctors. To verify the performance, numerous patients are tested. According to the results of the experiment, the procedure presented in this thesis for estimation of continuous blood pressure was able to effectively achieve the required functions. Jong-Hann Jean 簡忠漢 2010 學位論文 ; thesis 82 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 聖約翰科技大學 === 自動化及機電整合研究所 === 99 === In this thesis we present the development of a pulse oximeter to estimate continuous blood pressure based on photoplethysmograph and consider its application in home care scenario. In order to accomplish our goal, we combined a sphygmomanometer and a photoplethysmograph module to design a non-invasive blood pressure module which can estimate the continuous blood pressure. First, the Oscillometric Method was used to obtain the diastolic pressure and the systolic pressure of a person. The two parameters are further applied to calibration of the voltage-to-pressure ratio in a photoplethysmograph, which establishes the physiological parameter specific to each person. Second, not only to calculate the SPO2, our pulse oximeter can also measure the value of the continuous blood pressure and the heart rate in a non-invasive way. The pulse oximeter can display real-time results and store the information into a computer, allowing diagnostic reference for doctors. To verify the performance, numerous patients are tested. According to the results of the experiment, the procedure presented in this thesis for estimation of continuous blood pressure was able to effectively achieve the required functions.
|
author2 |
Jong-Hann Jean |
author_facet |
Jong-Hann Jean Chia-Chun Hong 洪嘉駿 |
author |
Chia-Chun Hong 洪嘉駿 |
spellingShingle |
Chia-Chun Hong 洪嘉駿 Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
author_sort |
Chia-Chun Hong |
title |
Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
title_short |
Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
title_full |
Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
title_fullStr |
Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
title_full_unstemmed |
Development of a Pulse Oximeter Module to Estimate Continuous Blood Pressure Based on Photoplethysmograph |
title_sort |
development of a pulse oximeter module to estimate continuous blood pressure based on photoplethysmograph |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/82443781257565730987 |
work_keys_str_mv |
AT chiachunhong developmentofapulseoximetermoduletoestimatecontinuousbloodpressurebasedonphotoplethysmograph AT hóngjiājùn developmentofapulseoximetermoduletoestimatecontinuousbloodpressurebasedonphotoplethysmograph AT chiachunhong yánzhìjīyúguāngtǐjīmiáohuìtúxùnhàozhīxuèyǎngbǎohénóngdùmózǔyǔqíyīngyòngyúliánxùxuèyāzhītuīgū AT hóngjiājùn yánzhìjīyúguāngtǐjīmiáohuìtúxùnhàozhīxuèyǎngbǎohénóngdùmózǔyǔqíyīngyòngyúliánxùxuèyāzhītuīgū |
_version_ |
1718231926922280960 |