Label-Free Capacitive Aptasensor for Thrombin
碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 100 === Capacitive biosensors are label-free and promising for developing hand-held devices and point-of-care applications. However, conventional micro-fabricated capacitive sensors such as those based on interdigitated electrodes faced the challenges including del...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2012
|
Online Access: | http://ndltd.ncl.edu.tw/handle/46002839286841802039 |
id |
ndltd-TW-100NTU05415005 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-100NTU054150052015-10-13T21:45:45Z http://ndltd.ncl.edu.tw/handle/46002839286841802039 Label-Free Capacitive Aptasensor for Thrombin 免標定電容式核酸適體生物感測器運用於凝血酶的檢測 Hsin-Ju Chen 陳欣儒 碩士 國立臺灣大學 生物產業機電工程學研究所 100 Capacitive biosensors are label-free and promising for developing hand-held devices and point-of-care applications. However, conventional micro-fabricated capacitive sensors such as those based on interdigitated electrodes faced the challenges including delicate manufacture and non-uniform distribution of electric field. Furthermore, electrochemical impedance spectroscopy for capacitance measurements usually required extra addition of redox species to enhanced sensitivity. A label-free and sensitive capacitive aptasensor was developed with simple design based on electrode pairs. The electrode pair was the transducer of the capacitive aptasensor, which was composed of a gold electrode (from compact discs) and an indium tin oxide (ITO) film with micrometer separation by a double-side PET tape. On the gold electrode was layered with aptamers as the bio-recognition elements and then a self-assembled monolayer of 1-dodecanethiol to prevent non-specific protein binding. Electrochemical characterization proved that the self-assembly monolayer also formed effective insulating layer adequate for capacitive sensing. Thrombin was selected as a model analyte to validate the assay. The capacitance change originated from thrombin binding with aptamers was measured with a home-made capacitance sensing circuit by switched capacitor technology. The linear range for thrombin detection in human serum was from 10-11 to 10-6 M with a regression coefficient of 0.97. Non-specific binding of bovine serum albumin (BSA) and human serum albumin (BSA) were not observed in the proposed aptasensor. This work demonstrated the successful application of label-free capacitive aptasensor for thrombin detection. It could be applied in the detection of other target proteins by replacing different aptamers. 鄭宗記 2012 學位論文 ; thesis 85 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 100 === Capacitive biosensors are label-free and promising for developing hand-held devices and point-of-care applications. However, conventional micro-fabricated capacitive sensors such as those based on interdigitated electrodes faced the challenges including delicate manufacture and non-uniform distribution of electric field. Furthermore, electrochemical impedance spectroscopy for capacitance measurements usually required extra addition of redox species to enhanced sensitivity. A label-free and sensitive capacitive aptasensor was developed with simple design based on electrode pairs. The electrode pair was the transducer of the capacitive aptasensor, which was composed of a gold electrode (from compact discs) and an indium tin oxide (ITO) film with micrometer separation by a double-side PET tape. On the gold electrode was layered with aptamers as the bio-recognition elements and then a self-assembled monolayer of 1-dodecanethiol to prevent non-specific protein binding. Electrochemical characterization proved that the self-assembly monolayer also formed effective insulating layer adequate for capacitive sensing. Thrombin was selected as a model analyte to validate the assay. The capacitance change originated from thrombin binding with aptamers was measured with a home-made capacitance sensing circuit by switched capacitor technology. The linear range for thrombin detection in human serum was from 10-11 to 10-6 M with a regression coefficient of 0.97. Non-specific binding of bovine serum albumin (BSA) and human serum albumin (BSA) were not observed in the proposed aptasensor. This work demonstrated the successful application of label-free capacitive aptasensor for thrombin detection. It could be applied in the detection of other target proteins by replacing different aptamers.
|
author2 |
鄭宗記 |
author_facet |
鄭宗記 Hsin-Ju Chen 陳欣儒 |
author |
Hsin-Ju Chen 陳欣儒 |
spellingShingle |
Hsin-Ju Chen 陳欣儒 Label-Free Capacitive Aptasensor for Thrombin |
author_sort |
Hsin-Ju Chen |
title |
Label-Free Capacitive Aptasensor for Thrombin |
title_short |
Label-Free Capacitive Aptasensor for Thrombin |
title_full |
Label-Free Capacitive Aptasensor for Thrombin |
title_fullStr |
Label-Free Capacitive Aptasensor for Thrombin |
title_full_unstemmed |
Label-Free Capacitive Aptasensor for Thrombin |
title_sort |
label-free capacitive aptasensor for thrombin |
publishDate |
2012 |
url |
http://ndltd.ncl.edu.tw/handle/46002839286841802039 |
work_keys_str_mv |
AT hsinjuchen labelfreecapacitiveaptasensorforthrombin AT chénxīnrú labelfreecapacitiveaptasensorforthrombin AT hsinjuchen miǎnbiāodìngdiànróngshìhésuānshìtǐshēngwùgǎncèqìyùnyòngyúníngxuèméidejiǎncè AT chénxīnrú miǎnbiāodìngdiànróngshìhésuānshìtǐshēngwùgǎncèqìyùnyòngyúníngxuèméidejiǎncè |
_version_ |
1718068263286472704 |