Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study

碩士 === 國立臺灣大學 === 臨床牙醫學研究所 === 100 === Since 1970s, replacement of missing teeth with dental implant has become a popular treatment option in dental treatment. The successful implant depended on the osseointegration between implant and bone which took a period of time for healing. Various surface tr...

Full description

Bibliographic Details
Main Authors: Sheng-Wei Chang, 張勝惟
Other Authors: Chun-Pin Lin
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/30512257462224516278
id ndltd-TW-100NTU05594003
record_format oai_dc
spelling ndltd-TW-100NTU055940032015-10-13T21:45:44Z http://ndltd.ncl.edu.tw/handle/30512257462224516278 Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study 噴砂酸蝕合併鹼酸熱處理對牙科植體骨整合之影響評估:動物試驗 Sheng-Wei Chang 張勝惟 碩士 國立臺灣大學 臨床牙醫學研究所 100 Since 1970s, replacement of missing teeth with dental implant has become a popular treatment option in dental treatment. The successful implant depended on the osseointegration between implant and bone which took a period of time for healing. Various surface treatment schemes on dental implant have being developed in order to hasten osseointegration thus shorten the healing time. Surface treatment scheme using sand-blasted, large grit, acid-etched surface treatment (SLA) has been proposed used for a period of time; however, SLA treated implant still need more healing time for osteointergration. Recently, a new surface treatment scheme using alkaline, acid and heat surface treatment (AAH) surface treatment has been proposed. The purpose of this study is to evaluate the effect of two new surface treatments (Sand-blasted ,Large grit, Acid -etched combined Alkaline ,Acid , Heat surface treatment(SLA+AAH)) on osseointegartion. Three different surface treatment implants with two type screw design, one surface treatment is SLA+AAH surface treatment type, the other is SLA (Sand-blasted, Large grit, Acid etched),with same screw design and TiUnite (Nobel Biocare - NP) were compared. Nine beagle dogs were enrolled in this study, divided into 3 groups (4, 8, 12 weeks), six dental implants were inserted in each dog included two experimental groups(SLA+AAH) and two control group(SLA and TiUnite). The assessments of implants are including clinical evaluation, survival rate, resonance frequency test and photo record. Experimental parameters including resonance frequency test(ISQ), bone implant contact (BIC) ,remove torque test were used to analysis the integration of bone and implant. The dogs were sacrificed at the time interval of 4, 8, 12 weeks for further histological analysis. In 8weeks group , implants were placed in tibia for removal torque test. The results showed the value of SLA+AAH surface treatment group in resonance frequency test is slightly higher than SLA group and TiUnite group . It seems that the potential for SLA+AAH chemical modification of the implant surface may possess good biologic events during the osseointegartion process and offer some superiority to implants with the SLA and TiUnite surface. Further study is needed to distinguish the variables for hastening of osseointegartion with modality of new surface treatment. Chun-Pin Lin Hao-Hueng Chang 林俊彬 章浩宏 2012 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 臨床牙醫學研究所 === 100 === Since 1970s, replacement of missing teeth with dental implant has become a popular treatment option in dental treatment. The successful implant depended on the osseointegration between implant and bone which took a period of time for healing. Various surface treatment schemes on dental implant have being developed in order to hasten osseointegration thus shorten the healing time. Surface treatment scheme using sand-blasted, large grit, acid-etched surface treatment (SLA) has been proposed used for a period of time; however, SLA treated implant still need more healing time for osteointergration. Recently, a new surface treatment scheme using alkaline, acid and heat surface treatment (AAH) surface treatment has been proposed. The purpose of this study is to evaluate the effect of two new surface treatments (Sand-blasted ,Large grit, Acid -etched combined Alkaline ,Acid , Heat surface treatment(SLA+AAH)) on osseointegartion. Three different surface treatment implants with two type screw design, one surface treatment is SLA+AAH surface treatment type, the other is SLA (Sand-blasted, Large grit, Acid etched),with same screw design and TiUnite (Nobel Biocare - NP) were compared. Nine beagle dogs were enrolled in this study, divided into 3 groups (4, 8, 12 weeks), six dental implants were inserted in each dog included two experimental groups(SLA+AAH) and two control group(SLA and TiUnite). The assessments of implants are including clinical evaluation, survival rate, resonance frequency test and photo record. Experimental parameters including resonance frequency test(ISQ), bone implant contact (BIC) ,remove torque test were used to analysis the integration of bone and implant. The dogs were sacrificed at the time interval of 4, 8, 12 weeks for further histological analysis. In 8weeks group , implants were placed in tibia for removal torque test. The results showed the value of SLA+AAH surface treatment group in resonance frequency test is slightly higher than SLA group and TiUnite group . It seems that the potential for SLA+AAH chemical modification of the implant surface may possess good biologic events during the osseointegartion process and offer some superiority to implants with the SLA and TiUnite surface. Further study is needed to distinguish the variables for hastening of osseointegartion with modality of new surface treatment.
author2 Chun-Pin Lin
author_facet Chun-Pin Lin
Sheng-Wei Chang
張勝惟
author Sheng-Wei Chang
張勝惟
spellingShingle Sheng-Wei Chang
張勝惟
Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
author_sort Sheng-Wei Chang
title Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
title_short Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
title_full Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
title_fullStr Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
title_full_unstemmed Effect of Sand-blasted, Large grit, Acid-etched Combined Alkaline, Acid, Heat Surface Treatment on Osteointergartion of Dental Implant: Animal study
title_sort effect of sand-blasted, large grit, acid-etched combined alkaline, acid, heat surface treatment on osteointergartion of dental implant: animal study
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/30512257462224516278
work_keys_str_mv AT shengweichang effectofsandblastedlargegritacidetchedcombinedalkalineacidheatsurfacetreatmentonosteointergartionofdentalimplantanimalstudy
AT zhāngshèngwéi effectofsandblastedlargegritacidetchedcombinedalkalineacidheatsurfacetreatmentonosteointergartionofdentalimplantanimalstudy
AT shengweichang pēnshāsuānshíhébìngjiǎnsuānrèchùlǐduìyákēzhítǐgǔzhěnghézhīyǐngxiǎngpínggūdòngwùshìyàn
AT zhāngshèngwéi pēnshāsuānshíhébìngjiǎnsuānrèchùlǐduìyákēzhítǐgǔzhěnghézhīyǐngxiǎngpínggūdòngwùshìyàn
_version_ 1718068363437015040