Design and Development of a Low-Power Wireless Blood Pressure Monitor

碩士 === 國立臺灣科技大學 === 電子工程系 === 100 === In this thesis, we developed a low-power wireless blood pressure monitor system, which comprises a homemade blood pressure measuring device and a smartphone. The device uses single chip (Bluetooth Low Energy System on Chip, BLE SoC) to process the algorithm of b...

Full description

Bibliographic Details
Main Authors: Zhe-Min Lin, 林哲民
Other Authors: Yuan-Hsiang Lin
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/43211614033958932269
id ndltd-TW-100NTUS5428110
record_format oai_dc
spelling ndltd-TW-100NTUS54281102015-10-13T21:17:26Z http://ndltd.ncl.edu.tw/handle/43211614033958932269 Design and Development of a Low-Power Wireless Blood Pressure Monitor 低功耗無線血壓計的設計與開發 Zhe-Min Lin 林哲民 碩士 國立臺灣科技大學 電子工程系 100 In this thesis, we developed a low-power wireless blood pressure monitor system, which comprises a homemade blood pressure measuring device and a smartphone. The device uses single chip (Bluetooth Low Energy System on Chip, BLE SoC) to process the algorithm of blood pressure measurement and perform data transmission. Through the newest Bluetooth Low Energy interface, this device can send measured results to the smartphone. Therefore, users can see the systolic, diastolic, mean blood pressure and pulse rate information on the smartphone. Besides, the data transmission packet format is based on the standard Blood Pressure Profile specification. Therefore, it has high compatibility to communication with other devices. The blood pressure measuring device can be divided into automatic and manual inflation mode in this thesis. It has very low power consumption and provides 4,400 measurements with a 220mAh battery in manual mode. For the reliability, the accuracy of pulse rate, systolic and diastolic blood pressures were verified by the CuffLink simulator. The accuracy of pulse rate is -1.13 ± 0.52 beats, the accuracy of systolic blood pressure is 0.69 ± 1.63 mmHg, and the accuracy of diastolic blood pressure is 0.20 ± 1.02 mmHg. In clinical trials, the systolic blood pressure average differences between our method and auscultation method is 2.66 ± 2.71 mmHg, the diastolic blood pressure average differences between our method and auscultation method is 3.42 ± 4.42 mmHg. As a result, this device has high accuracy for measuring blood pressure and pulse rate. Yuan-Hsiang Lin 林淵翔 2012 學位論文 ; thesis 81 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電子工程系 === 100 === In this thesis, we developed a low-power wireless blood pressure monitor system, which comprises a homemade blood pressure measuring device and a smartphone. The device uses single chip (Bluetooth Low Energy System on Chip, BLE SoC) to process the algorithm of blood pressure measurement and perform data transmission. Through the newest Bluetooth Low Energy interface, this device can send measured results to the smartphone. Therefore, users can see the systolic, diastolic, mean blood pressure and pulse rate information on the smartphone. Besides, the data transmission packet format is based on the standard Blood Pressure Profile specification. Therefore, it has high compatibility to communication with other devices. The blood pressure measuring device can be divided into automatic and manual inflation mode in this thesis. It has very low power consumption and provides 4,400 measurements with a 220mAh battery in manual mode. For the reliability, the accuracy of pulse rate, systolic and diastolic blood pressures were verified by the CuffLink simulator. The accuracy of pulse rate is -1.13 ± 0.52 beats, the accuracy of systolic blood pressure is 0.69 ± 1.63 mmHg, and the accuracy of diastolic blood pressure is 0.20 ± 1.02 mmHg. In clinical trials, the systolic blood pressure average differences between our method and auscultation method is 2.66 ± 2.71 mmHg, the diastolic blood pressure average differences between our method and auscultation method is 3.42 ± 4.42 mmHg. As a result, this device has high accuracy for measuring blood pressure and pulse rate.
author2 Yuan-Hsiang Lin
author_facet Yuan-Hsiang Lin
Zhe-Min Lin
林哲民
author Zhe-Min Lin
林哲民
spellingShingle Zhe-Min Lin
林哲民
Design and Development of a Low-Power Wireless Blood Pressure Monitor
author_sort Zhe-Min Lin
title Design and Development of a Low-Power Wireless Blood Pressure Monitor
title_short Design and Development of a Low-Power Wireless Blood Pressure Monitor
title_full Design and Development of a Low-Power Wireless Blood Pressure Monitor
title_fullStr Design and Development of a Low-Power Wireless Blood Pressure Monitor
title_full_unstemmed Design and Development of a Low-Power Wireless Blood Pressure Monitor
title_sort design and development of a low-power wireless blood pressure monitor
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/43211614033958932269
work_keys_str_mv AT zheminlin designanddevelopmentofalowpowerwirelessbloodpressuremonitor
AT línzhémín designanddevelopmentofalowpowerwirelessbloodpressuremonitor
AT zheminlin dīgōnghàowúxiànxuèyājìdeshèjìyǔkāifā
AT línzhémín dīgōnghàowúxiànxuèyājìdeshèjìyǔkāifā
_version_ 1718059947960303616