A Framework of Real-time Feedback System in MRI: Technique and Applications

博士 === 國立臺灣科技大學 === 電機工程系 === 100 === In MRI, some specific scan parameters such as inversion time or RF frequency offset have to be determined before applying clinical protocols. In general, the MR operators or doctors would utilize the developed scouting protocol and then select the proper imaging...

Full description

Bibliographic Details
Main Authors: Yu-wei Tang, 唐育尉
Other Authors: Teng-yi Huang
Format: Others
Language:en_US
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/cw6x84
id ndltd-TW-100NTUS5442083
record_format oai_dc
spelling ndltd-TW-100NTUS54420832019-05-15T20:43:22Z http://ndltd.ncl.edu.tw/handle/cw6x84 A Framework of Real-time Feedback System in MRI: Technique and Applications 即時回授系統架構於磁振造影之技術與應用 Yu-wei Tang 唐育尉 博士 國立臺灣科技大學 電機工程系 100 In MRI, some specific scan parameters such as inversion time or RF frequency offset have to be determined before applying clinical protocols. In general, the MR operators or doctors would utilize the developed scouting protocol and then select the proper imaging parameter according to the set of images manually. However, the additional scouting scan would diminish the fluency of clinical routine. In this thesis, we proposed a framework of real-time feedback system that could automatically and rapidly optimize the desired parameter. Two types of applications have been accomplished based on this real-time feedback system. The first application was to implement the optimization of compensative gradient moment for z-shim method in gradient-echo echo-planar-imaging (GE-EPI). In this type, the pre-scan and target sequences were identical. After about 20 iterations for evaluating optimal negative and positive z-shim gradient moments, the following z-shimmed GE-EPI for functional MRI (fMRI) study would contain images alternatively according to the inherited values. The second application is the calibration of RF frequency to suppress the dark banding artifact.in steady-state free precession (bSSFP) cardiac imaging at 3.0 T. The real-time feedback system combined two sequences: transition-band low flip-angle bSSFP (bSSSFP-L) for frequency calibration and conventional cine bSSFP. The optimal frequency obtained by real-time feedback calibration significantly reduced dark-band artifacts in cine bSSFP images (P < .01). The period of calibration and conventional protocol could be implemented within one breadth-hold. In conclusion, the proposed real-time feedback system is rapid and fully automatic and can thus serve as a pre-adjustment module in various MR researches which are in need of parameter calibration. Teng-yi Huang 黃騰毅 2012 學位論文 ; thesis 75 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 博士 === 國立臺灣科技大學 === 電機工程系 === 100 === In MRI, some specific scan parameters such as inversion time or RF frequency offset have to be determined before applying clinical protocols. In general, the MR operators or doctors would utilize the developed scouting protocol and then select the proper imaging parameter according to the set of images manually. However, the additional scouting scan would diminish the fluency of clinical routine. In this thesis, we proposed a framework of real-time feedback system that could automatically and rapidly optimize the desired parameter. Two types of applications have been accomplished based on this real-time feedback system. The first application was to implement the optimization of compensative gradient moment for z-shim method in gradient-echo echo-planar-imaging (GE-EPI). In this type, the pre-scan and target sequences were identical. After about 20 iterations for evaluating optimal negative and positive z-shim gradient moments, the following z-shimmed GE-EPI for functional MRI (fMRI) study would contain images alternatively according to the inherited values. The second application is the calibration of RF frequency to suppress the dark banding artifact.in steady-state free precession (bSSFP) cardiac imaging at 3.0 T. The real-time feedback system combined two sequences: transition-band low flip-angle bSSFP (bSSSFP-L) for frequency calibration and conventional cine bSSFP. The optimal frequency obtained by real-time feedback calibration significantly reduced dark-band artifacts in cine bSSFP images (P < .01). The period of calibration and conventional protocol could be implemented within one breadth-hold. In conclusion, the proposed real-time feedback system is rapid and fully automatic and can thus serve as a pre-adjustment module in various MR researches which are in need of parameter calibration.
author2 Teng-yi Huang
author_facet Teng-yi Huang
Yu-wei Tang
唐育尉
author Yu-wei Tang
唐育尉
spellingShingle Yu-wei Tang
唐育尉
A Framework of Real-time Feedback System in MRI: Technique and Applications
author_sort Yu-wei Tang
title A Framework of Real-time Feedback System in MRI: Technique and Applications
title_short A Framework of Real-time Feedback System in MRI: Technique and Applications
title_full A Framework of Real-time Feedback System in MRI: Technique and Applications
title_fullStr A Framework of Real-time Feedback System in MRI: Technique and Applications
title_full_unstemmed A Framework of Real-time Feedback System in MRI: Technique and Applications
title_sort framework of real-time feedback system in mri: technique and applications
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/cw6x84
work_keys_str_mv AT yuweitang aframeworkofrealtimefeedbacksysteminmritechniqueandapplications
AT tángyùwèi aframeworkofrealtimefeedbacksysteminmritechniqueandapplications
AT yuweitang jíshíhuíshòuxìtǒngjiàgòuyúcízhènzàoyǐngzhījìshùyǔyīngyòng
AT tángyùwèi jíshíhuíshòuxìtǒngjiàgòuyúcízhènzàoyǐngzhījìshùyǔyīngyòng
AT yuweitang frameworkofrealtimefeedbacksysteminmritechniqueandapplications
AT tángyùwèi frameworkofrealtimefeedbacksysteminmritechniqueandapplications
_version_ 1719104731551367168