Insulation Status Assessment of Underground Cable Joint based on Fractal Theory

碩士 === 國立臺灣科技大學 === 電機工程系 === 100 === In the recent years, the transmission way is changed from overhead line circuit to underground for power companies in the urban distribution systems. In the underground cables, the cable joints may be weak points for breakdown as a result of the construction of...

Full description

Bibliographic Details
Main Authors: Wei-Sheng, Cai, 蔡偉聖
Other Authors: Ruay-Nan Wu
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/08903387204111152291
id ndltd-TW-100NTUS5442099
record_format oai_dc
spelling ndltd-TW-100NTUS54420992015-10-13T21:17:26Z http://ndltd.ncl.edu.tw/handle/08903387204111152291 Insulation Status Assessment of Underground Cable Joint based on Fractal Theory 應用分形理論於地下電纜接頭絕緣狀態評估之研究 Wei-Sheng, Cai 蔡偉聖 碩士 國立臺灣科技大學 電機工程系 100 In the recent years, the transmission way is changed from overhead line circuit to underground for power companies in the urban distribution systems. In the underground cables, the cable joints may be weak points for breakdown as a result of the construction of the artificial defection. Therefore, exploring the underground cable joint insulation state is the most important issue. In this thesis, the cable joint is used as the test material in the partial discharge test and the artificial defect is produced in joints deliberately, and then applying high voltage to the test material until the insulation breakdown, during the trial term, the partial discharged data is retrieved by data captured card in the fixed time and by using filtering, simplification, conversion to extract the characteristic parameters and phase resolve pattern. Finally, the fractal dimension value is obtained by calculation of the phase resolve pattern for each pattern, and compared to each other characteristic parameters, by the calculation of the result mentioned above. The discharge sum and discharge number are the similar diameter trend, furthermore, the fractal dimension is limited to between 2 and 3. Finally, the first-order fitting error is calculated, and the differential thresholds are computed by the differential rates of the averaged error. Furthermore, the more precise dimension values among those tests in each condition are taken out. When dimension values are close to 2.25 or exceed, it will end in the insulating deterioration. Therefore, the appropriate warning can effectively reduce the accident occurance at this time. Ruay-Nan Wu 吳瑞南 2012 學位論文 ; thesis 91 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 100 === In the recent years, the transmission way is changed from overhead line circuit to underground for power companies in the urban distribution systems. In the underground cables, the cable joints may be weak points for breakdown as a result of the construction of the artificial defection. Therefore, exploring the underground cable joint insulation state is the most important issue. In this thesis, the cable joint is used as the test material in the partial discharge test and the artificial defect is produced in joints deliberately, and then applying high voltage to the test material until the insulation breakdown, during the trial term, the partial discharged data is retrieved by data captured card in the fixed time and by using filtering, simplification, conversion to extract the characteristic parameters and phase resolve pattern. Finally, the fractal dimension value is obtained by calculation of the phase resolve pattern for each pattern, and compared to each other characteristic parameters, by the calculation of the result mentioned above. The discharge sum and discharge number are the similar diameter trend, furthermore, the fractal dimension is limited to between 2 and 3. Finally, the first-order fitting error is calculated, and the differential thresholds are computed by the differential rates of the averaged error. Furthermore, the more precise dimension values among those tests in each condition are taken out. When dimension values are close to 2.25 or exceed, it will end in the insulating deterioration. Therefore, the appropriate warning can effectively reduce the accident occurance at this time.
author2 Ruay-Nan Wu
author_facet Ruay-Nan Wu
Wei-Sheng, Cai
蔡偉聖
author Wei-Sheng, Cai
蔡偉聖
spellingShingle Wei-Sheng, Cai
蔡偉聖
Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
author_sort Wei-Sheng, Cai
title Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
title_short Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
title_full Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
title_fullStr Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
title_full_unstemmed Insulation Status Assessment of Underground Cable Joint based on Fractal Theory
title_sort insulation status assessment of underground cable joint based on fractal theory
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/08903387204111152291
work_keys_str_mv AT weishengcai insulationstatusassessmentofundergroundcablejointbasedonfractaltheory
AT càiwěishèng insulationstatusassessmentofundergroundcablejointbasedonfractaltheory
AT weishengcai yīngyòngfēnxínglǐlùnyúdexiàdiànlǎnjiētóujuéyuánzhuàngtàipínggūzhīyánjiū
AT càiwěishèng yīngyòngfēnxínglǐlùnyúdexiàdiànlǎnjiētóujuéyuánzhuàngtàipínggūzhīyánjiū
_version_ 1718059983233351680