The Development and Application of Plantar Fasciitis Measuring System

碩士 === 臺北巿立體育學院 === 運動器材研究所 === 100 === Purpose: Plantar fascia, the function is to support and stability the arch for absorbing the impact force from ground. Long term over pulling of foot plantar will cause inflammation of the plantar fascia. Therefore, the purpose of present study was to deve...

Full description

Bibliographic Details
Main Authors: Chen, YiChieh, 陳奕捷
Other Authors: Ho, WeiHua
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/43nhrv
id ndltd-TW-100TPEC0799007
record_format oai_dc
spelling ndltd-TW-100TPEC07990072019-06-27T05:11:26Z http://ndltd.ncl.edu.tw/handle/43nhrv The Development and Application of Plantar Fasciitis Measuring System 足底筋膜量測系統之開發與人體功效研究 Chen, YiChieh 陳奕捷 碩士 臺北巿立體育學院 運動器材研究所 100 Purpose: Plantar fascia, the function is to support and stability the arch for absorbing the impact force from ground. Long term over pulling of foot plantar will cause inflammation of the plantar fascia. Therefore, the purpose of present study was to develop a new type “instrument of measuring plantar fascia”, which can observe the stress relaxation of plantar fascia as the reference of diagnosis. Methods: The first stage of this study was the instrument conceptual design and entity development. The second stage was to verify the accuracy of instrument. Finally, using the instrument for human body detect by observing the plantar fascia stiffness difference between feet of athletes; non athletes. Subjects were 117 different types, sexuality athletes and 28 non athletes. To measurement the plantar fascia of feet medial longitudinal arch and record the value of maximum force & relative deformation. Statistical analysis was used correlation analysis to verify the accuracy of instrument, paired T test to compare the differences of plantar fascia stiffness between left and right foot. Results: The result showed that the outcome of instrument was with high reliability and validity, and the differences of feet stiffness only in male basketball players are significant. There could speculate on its own body weight, training field and special action mode of male basketball players that would cause difference of feet structure and thereby the plantar fascia stiffness. Conclusion: The plantar fascia measuring system in this study can observe the relationship of plantar fascia withstand force and deformation, in order to understand the characteristic of plantar fascia differences in various subjects. In the future will improvement the structure of instrument for more different functional demands, expectation this instrument can be a reference for medical diagnosis or the development of shoe-related assistive device. Ho, WeiHua 何維華 2012 學位論文 ; thesis 85 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 臺北巿立體育學院 === 運動器材研究所 === 100 === Purpose: Plantar fascia, the function is to support and stability the arch for absorbing the impact force from ground. Long term over pulling of foot plantar will cause inflammation of the plantar fascia. Therefore, the purpose of present study was to develop a new type “instrument of measuring plantar fascia”, which can observe the stress relaxation of plantar fascia as the reference of diagnosis. Methods: The first stage of this study was the instrument conceptual design and entity development. The second stage was to verify the accuracy of instrument. Finally, using the instrument for human body detect by observing the plantar fascia stiffness difference between feet of athletes; non athletes. Subjects were 117 different types, sexuality athletes and 28 non athletes. To measurement the plantar fascia of feet medial longitudinal arch and record the value of maximum force & relative deformation. Statistical analysis was used correlation analysis to verify the accuracy of instrument, paired T test to compare the differences of plantar fascia stiffness between left and right foot. Results: The result showed that the outcome of instrument was with high reliability and validity, and the differences of feet stiffness only in male basketball players are significant. There could speculate on its own body weight, training field and special action mode of male basketball players that would cause difference of feet structure and thereby the plantar fascia stiffness. Conclusion: The plantar fascia measuring system in this study can observe the relationship of plantar fascia withstand force and deformation, in order to understand the characteristic of plantar fascia differences in various subjects. In the future will improvement the structure of instrument for more different functional demands, expectation this instrument can be a reference for medical diagnosis or the development of shoe-related assistive device.
author2 Ho, WeiHua
author_facet Ho, WeiHua
Chen, YiChieh
陳奕捷
author Chen, YiChieh
陳奕捷
spellingShingle Chen, YiChieh
陳奕捷
The Development and Application of Plantar Fasciitis Measuring System
author_sort Chen, YiChieh
title The Development and Application of Plantar Fasciitis Measuring System
title_short The Development and Application of Plantar Fasciitis Measuring System
title_full The Development and Application of Plantar Fasciitis Measuring System
title_fullStr The Development and Application of Plantar Fasciitis Measuring System
title_full_unstemmed The Development and Application of Plantar Fasciitis Measuring System
title_sort development and application of plantar fasciitis measuring system
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/43nhrv
work_keys_str_mv AT chenyichieh thedevelopmentandapplicationofplantarfasciitismeasuringsystem
AT chényìjié thedevelopmentandapplicationofplantarfasciitismeasuringsystem
AT chenyichieh zúdǐjīnmóliàngcèxìtǒngzhīkāifāyǔréntǐgōngxiàoyánjiū
AT chényìjié zúdǐjīnmóliàngcèxìtǒngzhīkāifāyǔréntǐgōngxiàoyánjiū
AT chenyichieh developmentandapplicationofplantarfasciitismeasuringsystem
AT chényìjié developmentandapplicationofplantarfasciitismeasuringsystem
_version_ 1719210662965542912