New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases
碩士 === 國立臺北科技大學 === 化學工程研究所 === 101 === The thiols are part of endogenous antioxidant system that maintains the cells’ normal redox potential and prominent biomarkers. Previously our group had prepared and demonstrated a new long-wavelength latent florescent probe, BCC, to detect Cys and GSH. We exp...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2013
|
Online Access: | http://ndltd.ncl.edu.tw/handle/yx7ufg |
id |
ndltd-TW-101TIT05063077 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-101TIT050630772019-05-15T21:02:29Z http://ndltd.ncl.edu.tw/handle/yx7ufg New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases 利用酵素法建立檢測輔酶A平台應用在乙醯轉化酶的檢測分析 Ming-Hui Wang 王茗卉 碩士 國立臺北科技大學 化學工程研究所 101 The thiols are part of endogenous antioxidant system that maintains the cells’ normal redox potential and prominent biomarkers. Previously our group had prepared and demonstrated a new long-wavelength latent florescent probe, BCC, to detect Cys and GSH. We expect to extend the application of BCC for assaying CoA and establishing platform applicable to monitor acetyl transferases. We have successful implemented the first long-wavelength latent fluorogenic substrate BCC as the off-on flourimetric indicators for detecting CoA; the fluorescence signal generated by this assay is specific. Furthermore, BCC, acetyl-CoA, and CAT or CrAT with the presence of corresponding substrate are easy assay platform for real time monitoring either CAT or CrAT enzymatic activities. In-retrospect, BCC, acetyl-CoA, and CrAT is a sensitive fluorimetric indicator for quantitatively measuring carnitine in the nanomolar ranges. This CoA platform for carnitine is expected to be applicable to measure broad ranges of important physiological analyte for the clinical diagnostic. Sheng-Tung Huang 黃聲東 2013 學位論文 ; thesis 63 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺北科技大學 === 化學工程研究所 === 101 === The thiols are part of endogenous antioxidant system that maintains the cells’ normal redox potential and prominent biomarkers. Previously our group had prepared and demonstrated a new long-wavelength latent florescent probe, BCC, to detect Cys and GSH. We expect to extend the application of BCC for assaying CoA and establishing platform applicable to monitor acetyl transferases. We have successful implemented the first long-wavelength latent fluorogenic substrate BCC as the off-on flourimetric indicators for detecting CoA; the fluorescence signal generated by this assay is specific. Furthermore, BCC, acetyl-CoA, and CAT or CrAT with the presence of corresponding substrate are easy assay platform for real time monitoring either CAT or CrAT enzymatic activities. In-retrospect, BCC, acetyl-CoA, and CrAT is a sensitive fluorimetric indicator for quantitatively measuring carnitine in the nanomolar ranges. This CoA platform for carnitine is expected to be applicable to measure broad ranges of important physiological analyte for the clinical diagnostic.
|
author2 |
Sheng-Tung Huang |
author_facet |
Sheng-Tung Huang Ming-Hui Wang 王茗卉 |
author |
Ming-Hui Wang 王茗卉 |
spellingShingle |
Ming-Hui Wang 王茗卉 New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
author_sort |
Ming-Hui Wang |
title |
New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
title_short |
New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
title_full |
New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
title_fullStr |
New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
title_full_unstemmed |
New Coenzyme A Fluorescence Detecting Platform : Applicable toMonitoring Acetyl Transferases |
title_sort |
new coenzyme a fluorescence detecting platform : applicable tomonitoring acetyl transferases |
publishDate |
2013 |
url |
http://ndltd.ncl.edu.tw/handle/yx7ufg |
work_keys_str_mv |
AT minghuiwang newcoenzymeafluorescencedetectingplatformapplicabletomonitoringacetyltransferases AT wángmínghuì newcoenzymeafluorescencedetectingplatformapplicabletomonitoringacetyltransferases AT minghuiwang lìyòngjiàosùfǎjiànlìjiǎncèfǔméiapíngtáiyīngyòngzàiyǐxīzhuǎnhuàméidejiǎncèfēnxī AT wángmínghuì lìyòngjiàosùfǎjiànlìjiǎncèfǔméiapíngtáiyīngyòngzàiyǐxīzhuǎnhuàméidejiǎncèfēnxī |
_version_ |
1719107536977657856 |