Retrofit of split air-conditioner with R-290

碩士 === 國立勤益科技大學 === 冷凍空調系 === 102 === This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-st...

Full description

Bibliographic Details
Main Authors: PU-NINE-LI, 浦念理
Other Authors: lee jing nan
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/80749097839598911401
id ndltd-TW-102NCIT5680022
record_format oai_dc
spelling ndltd-TW-102NCIT56800222016-09-25T04:04:35Z http://ndltd.ncl.edu.tw/handle/80749097839598911401 Retrofit of split air-conditioner with R-290 既設空調機換裝R-290環保冷媒探討 PU-NINE-LI 浦念理 碩士 國立勤益科技大學 冷凍空調系 102 This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-stage refrigeration cycle system through simulation results that R-290 R-22 have more than excellent compression ratio and coefficient of performance, safety refrigerant after analysis, the analysis result that the refrigerant R-290 in a hazardous environment and the refrigerant filling amount experiment no spontaneous combustion of the explosive, so selected as for R-290 Dress cold refrigerant, then, the amount of measuring instruments calibrated compare and choose a smaller error rate measurement instruments, then selected the same conditions with the air conditioner simulation parameters, and then measuring instruments installed air conditioners and record data, so getThe operating properties of system, which involves condensing and evaporation pressure, supplied air temperature, power consuming and performance coefficient, are introduced to balance the effect of refrigerant change. The analysis shows that in the system with rated 680(g), 50%~55% R-290 refrigerant filling has same performance as R-22 amount is 680(g). lee jing nan 李靖男 2014 學位論文 ; thesis 57 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立勤益科技大學 === 冷凍空調系 === 102 === This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-stage refrigeration cycle system through simulation results that R-290 R-22 have more than excellent compression ratio and coefficient of performance, safety refrigerant after analysis, the analysis result that the refrigerant R-290 in a hazardous environment and the refrigerant filling amount experiment no spontaneous combustion of the explosive, so selected as for R-290 Dress cold refrigerant, then, the amount of measuring instruments calibrated compare and choose a smaller error rate measurement instruments, then selected the same conditions with the air conditioner simulation parameters, and then measuring instruments installed air conditioners and record data, so getThe operating properties of system, which involves condensing and evaporation pressure, supplied air temperature, power consuming and performance coefficient, are introduced to balance the effect of refrigerant change. The analysis shows that in the system with rated 680(g), 50%~55% R-290 refrigerant filling has same performance as R-22 amount is 680(g).
author2 lee jing nan
author_facet lee jing nan
PU-NINE-LI
浦念理
author PU-NINE-LI
浦念理
spellingShingle PU-NINE-LI
浦念理
Retrofit of split air-conditioner with R-290
author_sort PU-NINE-LI
title Retrofit of split air-conditioner with R-290
title_short Retrofit of split air-conditioner with R-290
title_full Retrofit of split air-conditioner with R-290
title_fullStr Retrofit of split air-conditioner with R-290
title_full_unstemmed Retrofit of split air-conditioner with R-290
title_sort retrofit of split air-conditioner with r-290
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/80749097839598911401
work_keys_str_mv AT punineli retrofitofsplitairconditionerwithr290
AT pǔniànlǐ retrofitofsplitairconditionerwithr290
AT punineli jìshèkōngdiàojīhuànzhuāngr290huánbǎolěngméitàntǎo
AT pǔniànlǐ jìshèkōngdiàojīhuànzhuāngr290huánbǎolěngméitàntǎo
_version_ 1718384830852366336