Retrofit of split air-conditioner with R-290
碩士 === 國立勤益科技大學 === 冷凍空調系 === 102 === This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-st...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/80749097839598911401 |
id |
ndltd-TW-102NCIT5680022 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NCIT56800222016-09-25T04:04:35Z http://ndltd.ncl.edu.tw/handle/80749097839598911401 Retrofit of split air-conditioner with R-290 既設空調機換裝R-290環保冷媒探討 PU-NINE-LI 浦念理 碩士 國立勤益科技大學 冷凍空調系 102 This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-stage refrigeration cycle system through simulation results that R-290 R-22 have more than excellent compression ratio and coefficient of performance, safety refrigerant after analysis, the analysis result that the refrigerant R-290 in a hazardous environment and the refrigerant filling amount experiment no spontaneous combustion of the explosive, so selected as for R-290 Dress cold refrigerant, then, the amount of measuring instruments calibrated compare and choose a smaller error rate measurement instruments, then selected the same conditions with the air conditioner simulation parameters, and then measuring instruments installed air conditioners and record data, so getThe operating properties of system, which involves condensing and evaporation pressure, supplied air temperature, power consuming and performance coefficient, are introduced to balance the effect of refrigerant change. The analysis shows that in the system with rated 680(g), 50%~55% R-290 refrigerant filling has same performance as R-22 amount is 680(g). lee jing nan 李靖男 2014 學位論文 ; thesis 57 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立勤益科技大學 === 冷凍空調系 === 102 === This study proposes an experimental platform for retrofiting the existing R-22 system with the R-290 due to the physical properties and safety concern. The operating properties of system. while the use of simulation applications CoolPack R-22 and R-290 single-stage refrigeration cycle system through simulation results that R-290 R-22 have more than excellent compression ratio and coefficient of performance, safety refrigerant after analysis, the analysis result that the refrigerant R-290 in a hazardous environment and the refrigerant filling amount experiment no spontaneous combustion of the explosive, so selected as for R-290 Dress cold refrigerant, then, the amount of measuring instruments calibrated compare and choose a smaller error rate measurement instruments, then selected the same conditions with the air conditioner simulation parameters, and then measuring instruments installed air conditioners and record data, so getThe operating properties of system, which involves condensing and evaporation pressure, supplied air temperature, power consuming and performance coefficient, are introduced to balance the effect of refrigerant change. The analysis shows that in the system with rated 680(g), 50%~55% R-290 refrigerant filling has same performance as R-22 amount is 680(g).
|
author2 |
lee jing nan |
author_facet |
lee jing nan PU-NINE-LI 浦念理 |
author |
PU-NINE-LI 浦念理 |
spellingShingle |
PU-NINE-LI 浦念理 Retrofit of split air-conditioner with R-290 |
author_sort |
PU-NINE-LI |
title |
Retrofit of split air-conditioner with R-290 |
title_short |
Retrofit of split air-conditioner with R-290 |
title_full |
Retrofit of split air-conditioner with R-290 |
title_fullStr |
Retrofit of split air-conditioner with R-290 |
title_full_unstemmed |
Retrofit of split air-conditioner with R-290 |
title_sort |
retrofit of split air-conditioner with r-290 |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/80749097839598911401 |
work_keys_str_mv |
AT punineli retrofitofsplitairconditionerwithr290 AT pǔniànlǐ retrofitofsplitairconditionerwithr290 AT punineli jìshèkōngdiàojīhuànzhuāngr290huánbǎolěngméitàntǎo AT pǔniànlǐ jìshèkōngdiàojīhuànzhuāngr290huánbǎolěngméitàntǎo |
_version_ |
1718384830852366336 |