Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution

碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 102 === The head lamp affecting traffic safety, and the appearance is also a focus. When the illumination to produce high temperature. Made such as fog, parts melt, thermal aging or other situations. These situations are just about safety and appearance. So, to imp...

Full description

Bibliographic Details
Main Authors: Po-Jen Chen, 陳伯仁
Other Authors: Wei-Ching Chuang
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/fkuws5
id ndltd-TW-102NYPI5124014
record_format oai_dc
spelling ndltd-TW-102NYPI51240142019-09-21T03:32:27Z http://ndltd.ncl.edu.tw/handle/fkuws5 Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution 用以改善熱分佈均勻性之車燈排氣結構之分析與驗證 Po-Jen Chen 陳伯仁 碩士 國立虎尾科技大學 光電與材料科技研究所 102 The head lamp affecting traffic safety, and the appearance is also a focus. When the illumination to produce high temperature. Made such as fog, parts melt, thermal aging or other situations. These situations are just about safety and appearance. So, to improve these conditions, all the head lmap add vent. It help the lamp can be thermal convection. By thermal convection so that the internal temperature distribution. But in order to dust. Plus the vent tube or vent assembly will directly affect the performance of convection. So for these two parts for analysis. In this study. We used the same sample to test these different equipment. One is vent tube, and the other one is vent assembly. Then, through CFD software analysis the flow field. Compare the inner and outer parts changes in temperature, and the air velocity of flow at the vent. Through the analysis could find, used vent tube, the temperature was lower than used the vent assembly. At the maximum temperature difference of about 5℃. And by the flow rate analysis could find, when used vent tube, the flow rate is about 0.5 m / s, when used vent assembly, the flow rate is about 0.3 m / s. So the vent tube is more fast than vent assembly. In order to verify the correctness of the software analysis. We lighting fixtures to verify. Analysis shows that the position of the highest temperature, where the position at the top of the lamp envelope. So we measured this position. The temperature of vent tube is 66.9℃. And the temperature of vent assembly is 71.2℃ . Compare the data of these two. The result is the performance by vent tube better than vent assembly. Wei-Ching Chuang 莊為群 2014 學位論文 ; thesis 54 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 102 === The head lamp affecting traffic safety, and the appearance is also a focus. When the illumination to produce high temperature. Made such as fog, parts melt, thermal aging or other situations. These situations are just about safety and appearance. So, to improve these conditions, all the head lmap add vent. It help the lamp can be thermal convection. By thermal convection so that the internal temperature distribution. But in order to dust. Plus the vent tube or vent assembly will directly affect the performance of convection. So for these two parts for analysis. In this study. We used the same sample to test these different equipment. One is vent tube, and the other one is vent assembly. Then, through CFD software analysis the flow field. Compare the inner and outer parts changes in temperature, and the air velocity of flow at the vent. Through the analysis could find, used vent tube, the temperature was lower than used the vent assembly. At the maximum temperature difference of about 5℃. And by the flow rate analysis could find, when used vent tube, the flow rate is about 0.5 m / s, when used vent assembly, the flow rate is about 0.3 m / s. So the vent tube is more fast than vent assembly. In order to verify the correctness of the software analysis. We lighting fixtures to verify. Analysis shows that the position of the highest temperature, where the position at the top of the lamp envelope. So we measured this position. The temperature of vent tube is 66.9℃. And the temperature of vent assembly is 71.2℃ . Compare the data of these two. The result is the performance by vent tube better than vent assembly.
author2 Wei-Ching Chuang
author_facet Wei-Ching Chuang
Po-Jen Chen
陳伯仁
author Po-Jen Chen
陳伯仁
spellingShingle Po-Jen Chen
陳伯仁
Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
author_sort Po-Jen Chen
title Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
title_short Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
title_full Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
title_fullStr Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
title_full_unstemmed Analysis and Investigation of the Venting Structure in a Vehicle Lamp to Improve the Uniformity of the Heat Distribution
title_sort analysis and investigation of the venting structure in a vehicle lamp to improve the uniformity of the heat distribution
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/fkuws5
work_keys_str_mv AT pojenchen analysisandinvestigationoftheventingstructureinavehiclelamptoimprovetheuniformityoftheheatdistribution
AT chénbórén analysisandinvestigationoftheventingstructureinavehiclelamptoimprovetheuniformityoftheheatdistribution
AT pojenchen yòngyǐgǎishànrèfēnbùjūnyúnxìngzhīchēdēngpáiqìjiégòuzhīfēnxīyǔyànzhèng
AT chénbórén yòngyǐgǎishànrèfēnbùjūnyúnxìngzhīchēdēngpáiqìjiégòuzhīfēnxīyǔyànzhèng
_version_ 1719253338553319424