Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section

碩士 === 國立臺北科技大學 === 機電整合研究所 === 102 === 3C products have been designed toward thinner and tiny scale as a result of attracting more attention of consumers. Thus, the improved efficiency of heat dissipation for electronic devices a difficult challenge. Vapor chamber is one kind of cooling system usin...

Full description

Bibliographic Details
Main Authors: Wei-Ting Kuo, 郭韋廷
Other Authors: Cherng-Yuh Su
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/ut5cty
id ndltd-TW-102TIT05651090
record_format oai_dc
spelling ndltd-TW-102TIT056510902019-05-15T21:42:33Z http://ndltd.ncl.edu.tw/handle/ut5cty Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section 均熱板蒸氣流道與蒸發區結構對熱阻性能影響之研究 Wei-Ting Kuo 郭韋廷 碩士 國立臺北科技大學 機電整合研究所 102 3C products have been designed toward thinner and tiny scale as a result of attracting more attention of consumers. Thus, the improved efficiency of heat dissipation for electronic devices a difficult challenge. Vapor chamber is one kind of cooling system using theory of changed thermal conductivity from two-phase, which is based on heat pipe. This two-phase component consists of a wick structure which is inside the vacuum chamber wall; using the working fluid evaporation and condensation characteristic to speed up the thermal transmission. In this study, we fabricate the thin vapor chamber with using different vapor flow channel width, and different shapes of sintered copper powder inside the cavity of the evaporation area, to investigate the impact on performance of the vapor chamber. For this research, we use 0.6 mm thickness as the vapor space height. Preparation of 2, 4, 6 mm vapor flow channel width and different wick shape in evaporation area of the vapor chamber. Compare with normal vapor chamber and copper to detection performance. The result in different flow channel width test shows that w6 VC has a minimum resistance 0.194 ΔT/W at 100 W. In hybrids wick test, The cross groove VC has 0.186 ΔT/W resistance at 100 W. This study successfully improved the thin vapor chamber’s high heat resistance problem. Cherng-Yuh Su 蘇程裕 2014 學位論文 ; thesis 63 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 機電整合研究所 === 102 === 3C products have been designed toward thinner and tiny scale as a result of attracting more attention of consumers. Thus, the improved efficiency of heat dissipation for electronic devices a difficult challenge. Vapor chamber is one kind of cooling system using theory of changed thermal conductivity from two-phase, which is based on heat pipe. This two-phase component consists of a wick structure which is inside the vacuum chamber wall; using the working fluid evaporation and condensation characteristic to speed up the thermal transmission. In this study, we fabricate the thin vapor chamber with using different vapor flow channel width, and different shapes of sintered copper powder inside the cavity of the evaporation area, to investigate the impact on performance of the vapor chamber. For this research, we use 0.6 mm thickness as the vapor space height. Preparation of 2, 4, 6 mm vapor flow channel width and different wick shape in evaporation area of the vapor chamber. Compare with normal vapor chamber and copper to detection performance. The result in different flow channel width test shows that w6 VC has a minimum resistance 0.194 ΔT/W at 100 W. In hybrids wick test, The cross groove VC has 0.186 ΔT/W resistance at 100 W. This study successfully improved the thin vapor chamber’s high heat resistance problem.
author2 Cherng-Yuh Su
author_facet Cherng-Yuh Su
Wei-Ting Kuo
郭韋廷
author Wei-Ting Kuo
郭韋廷
spellingShingle Wei-Ting Kuo
郭韋廷
Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
author_sort Wei-Ting Kuo
title Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
title_short Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
title_full Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
title_fullStr Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
title_full_unstemmed Study on the Performance of Vapor Chamber in Different Vapor Flow Channel and Structural of Evaporation Section
title_sort study on the performance of vapor chamber in different vapor flow channel and structural of evaporation section
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/ut5cty
work_keys_str_mv AT weitingkuo studyontheperformanceofvaporchamberindifferentvaporflowchannelandstructuralofevaporationsection
AT guōwéitíng studyontheperformanceofvaporchamberindifferentvaporflowchannelandstructuralofevaporationsection
AT weitingkuo jūnrèbǎnzhēngqìliúdàoyǔzhēngfāqūjiégòuduìrèzǔxìngnéngyǐngxiǎngzhīyánjiū
AT guōwéitíng jūnrèbǎnzhēngqìliúdàoyǔzhēngfāqūjiégòuduìrèzǔxìngnéngyǐngxiǎngzhīyánjiū
_version_ 1719118366555242496