Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes

碩士 === 國立臺灣科技大學 === 化學工程系 === 103 === A convenient method for fabricating a sensitive indirect sandwich type electrochemical ELISA for the detection of estradiol using a chitosan electrodeposited platinum (Pt) wire microelectrode was proposed. In this assay, anti-17β estradiol produced in goat was u...

Full description

Bibliographic Details
Main Authors: Arwinda Gusviputri, 楊慎威
Other Authors: Tina T.-C.Tseng
Format: Others
Language:en_US
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/2s53ca
id ndltd-TW-103NTUS5342062
record_format oai_dc
spelling ndltd-TW-103NTUS53420622019-05-15T22:17:44Z http://ndltd.ncl.edu.tw/handle/2s53ca Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes 以幾丁聚醣沉積於微白金探針為基礎所製備的電化學式雌二醇酵素連結免疫吸附分析技術 Arwinda Gusviputri 楊慎威 碩士 國立臺灣科技大學 化學工程系 103 A convenient method for fabricating a sensitive indirect sandwich type electrochemical ELISA for the detection of estradiol using a chitosan electrodeposited platinum (Pt) wire microelectrode was proposed. In this assay, anti-17β estradiol produced in goat was used as the capture antibody which was immobilized on the chitosan coated Pt wire microelectrode, anti-17β estradiol 6 antibody produced in mouse was used as the detection antibody, and goat anti-mouse IgG conjugated with alkaline phosphatase (AP) was used as the secondary antibody. 4-Aminophenyl phosphate (4-APP) was chosen as the AP substrate and the oxidation potential of the electroactive AP product, 4-amino phenyl (4-AP), on the Pt electrode was determined to be +0.14 V (vs. Ag/AgCl). The electrochemical ELISA was detected by constant potential amperometry at +0.14 V in the Tris buffer (pH 9.0). The sensitivity (limit of detection) of this assay was 0.27 pg/mL with a wide detection range from 0.27 pg/mL up to 100 ng/mL. The assay specificity evaluated by testing the cross-reactivity of the assay against progesterone and 17α-ethynylestradiol was found to be 0.033% and 3.35%, respectively. The calibration curve of this assay tested in serum was also established. In this study, a sensitive, inexpensive, disposable, and easy to be fabricated electrochemical ELISA for estradiol was demonstrated. Tina T.-C.Tseng 曾婷芝 2015 學位論文 ; thesis 47 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 化學工程系 === 103 === A convenient method for fabricating a sensitive indirect sandwich type electrochemical ELISA for the detection of estradiol using a chitosan electrodeposited platinum (Pt) wire microelectrode was proposed. In this assay, anti-17β estradiol produced in goat was used as the capture antibody which was immobilized on the chitosan coated Pt wire microelectrode, anti-17β estradiol 6 antibody produced in mouse was used as the detection antibody, and goat anti-mouse IgG conjugated with alkaline phosphatase (AP) was used as the secondary antibody. 4-Aminophenyl phosphate (4-APP) was chosen as the AP substrate and the oxidation potential of the electroactive AP product, 4-amino phenyl (4-AP), on the Pt electrode was determined to be +0.14 V (vs. Ag/AgCl). The electrochemical ELISA was detected by constant potential amperometry at +0.14 V in the Tris buffer (pH 9.0). The sensitivity (limit of detection) of this assay was 0.27 pg/mL with a wide detection range from 0.27 pg/mL up to 100 ng/mL. The assay specificity evaluated by testing the cross-reactivity of the assay against progesterone and 17α-ethynylestradiol was found to be 0.033% and 3.35%, respectively. The calibration curve of this assay tested in serum was also established. In this study, a sensitive, inexpensive, disposable, and easy to be fabricated electrochemical ELISA for estradiol was demonstrated.
author2 Tina T.-C.Tseng
author_facet Tina T.-C.Tseng
Arwinda Gusviputri
楊慎威
author Arwinda Gusviputri
楊慎威
spellingShingle Arwinda Gusviputri
楊慎威
Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
author_sort Arwinda Gusviputri
title Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
title_short Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
title_full Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
title_fullStr Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
title_full_unstemmed Electrochemical ELISA for Estradiol Based on Chitosan Deposited Micro-platinum Probes
title_sort electrochemical elisa for estradiol based on chitosan deposited micro-platinum probes
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/2s53ca
work_keys_str_mv AT arwindagusviputri electrochemicalelisaforestradiolbasedonchitosandepositedmicroplatinumprobes
AT yángshènwēi electrochemicalelisaforestradiolbasedonchitosandepositedmicroplatinumprobes
AT arwindagusviputri yǐjǐdīngjùtángchénjīyúwēibáijīntànzhēnwèijīchǔsuǒzhìbèidediànhuàxuéshìcíèrchúnjiàosùliánjiémiǎnyìxīfùfēnxījìshù
AT yángshènwēi yǐjǐdīngjùtángchénjīyúwēibáijīntànzhēnwèijīchǔsuǒzhìbèidediànhuàxuéshìcíèrchúnjiàosùliánjiémiǎnyìxīfùfēnxījìshù
_version_ 1719128099245785088