A study of the improvement for fire detectors

碩士 === 吳鳳科技大學 === 消防研究所 === 104 === Given the fact that the labor occupational accidents occur frequently over the past few years, the number of casualties has remained high; especially in the construction industry, the percentage of employers to be disable or to lose their lives due to accidental f...

Full description

Bibliographic Details
Main Authors: Huang Ying Hsueh, 黃英學
Other Authors: Chi Jen-Hao
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/51612746405336386888
Description
Summary:碩士 === 吳鳳科技大學 === 消防研究所 === 104 === Given the fact that the labor occupational accidents occur frequently over the past few years, the number of casualties has remained high; especially in the construction industry, the percentage of employers to be disable or to lose their lives due to accidental fall has reached 50%. One of the remarkable instances is when professional labors are installing or advancing the fire-fighting systems, they are more likely to fall. In this paper, in the purpose of improving the potential factors that may harm labors as they install fire detectors or climb up high to make maintenances of the fire-fighting system, the author purpose a strategy, trying to create a safer environment for every worker. The advantages of the strategy that will be addressed in the paper: 1. Cut down a great deal of maintenance fee for type P fire alarm inspection system. 2. During the fire alarm system inspection or repair process, it will not cause any interference to the companies that receive the service. 3. The device is much easier to spot when it broke down since it is equipped with a small lightbulb inside, and when the light is out, it means something has gone wrong in the device. 4. Fire detectors will be repaired or replaced on the ground to avoid the danger of falling. 5. Fire detectors will be repaired or replaced on the ground so as to boost the efficiency of work. 6. Fire detection monitoring circuit or control loop checks on the ground as much as possible to reduce the probability of industrial safety events. 7. Even without the original design map of the circuit diagram, we can still visually configure the path clear line of fire detectors, the rise of view can be found to monitor or control malfunction or the fire detectors’ position, improve maintenance efficiency.