Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner

碩士 === 國立臺灣師範大學 === 工業教育學系 === 105 === This study aimed to enhance the performance of R-410A split air conditioner by using moisture transferring and quick drying textiles (MTQDT). The main method is decreased compressor temperature through evaporative cooling effect of the MTQDT and achieved the pu...

Full description

Bibliographic Details
Main Authors: Chen, Wei-Han, 陳韋翰
Other Authors: Mo, Huai-En
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/mqrf7s
id ndltd-TW-105NTNU5037019
record_format oai_dc
spelling ndltd-TW-105NTNU50370192019-05-15T23:46:58Z http://ndltd.ncl.edu.tw/handle/mqrf7s Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner 使用吸濕速乾纖維散熱以提升R-410A分離式冷氣機性能研究 Chen, Wei-Han 陳韋翰 碩士 國立臺灣師範大學 工業教育學系 105 This study aimed to enhance the performance of R-410A split air conditioner by using moisture transferring and quick drying textiles (MTQDT). The main method is decreased compressor temperature through evaporative cooling effect of the MTQDT and achieved the purpose of this study. We went on performance measurement using the same indoor load and the different ambient temperature (30±1°C, 35±1°C and 40±1°C). The results show that the MTQDT can successfully apply in a R410A split air conditioner. In the ambient temperature of 30°C, 35°C and 40°C, it prove that the compressor outlet temperature is reduced by 7.5%, 7.4% and 6.2%, the COP is improved by 20.68, 18.3% and 17.69%, and the EER is raised by 4.39%, 6.42% and 4.87%. Mo, Huai-En 莫懷恩 2017 學位論文 ; thesis 58 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣師範大學 === 工業教育學系 === 105 === This study aimed to enhance the performance of R-410A split air conditioner by using moisture transferring and quick drying textiles (MTQDT). The main method is decreased compressor temperature through evaporative cooling effect of the MTQDT and achieved the purpose of this study. We went on performance measurement using the same indoor load and the different ambient temperature (30±1°C, 35±1°C and 40±1°C). The results show that the MTQDT can successfully apply in a R410A split air conditioner. In the ambient temperature of 30°C, 35°C and 40°C, it prove that the compressor outlet temperature is reduced by 7.5%, 7.4% and 6.2%, the COP is improved by 20.68, 18.3% and 17.69%, and the EER is raised by 4.39%, 6.42% and 4.87%.
author2 Mo, Huai-En
author_facet Mo, Huai-En
Chen, Wei-Han
陳韋翰
author Chen, Wei-Han
陳韋翰
spellingShingle Chen, Wei-Han
陳韋翰
Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
author_sort Chen, Wei-Han
title Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
title_short Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
title_full Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
title_fullStr Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
title_full_unstemmed Use moisture wicking fiber evapotranspiration to enhance performance of R-410A split air conditioner
title_sort use moisture wicking fiber evapotranspiration to enhance performance of r-410a split air conditioner
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/mqrf7s
work_keys_str_mv AT chenweihan usemoisturewickingfiberevapotranspirationtoenhanceperformanceofr410asplitairconditioner
AT chénwéihàn usemoisturewickingfiberevapotranspirationtoenhanceperformanceofr410asplitairconditioner
AT chenweihan shǐyòngxīshīsùgānxiānwéisànrèyǐtíshēngr410afēnlíshìlěngqìjīxìngnéngyánjiū
AT chénwéihàn shǐyòngxīshīsùgānxiānwéisànrèyǐtíshēngr410afēnlíshìlěngqìjīxìngnéngyánjiū
_version_ 1719153576647852032