Dose evaluation of computed tomography in children abdomen with TLD

碩士 === 慈濟科技大學 === 放射醫學科學研究所 === 104 === Abstract CT (computed tomography) is widely used in the clinical hospital of medical imaging, computer tomography is a fast, non-intrusive inspection equipment, but it is of Radiology in the highest dose of radiation instruments. The appropriate scanning pa...

Full description

Bibliographic Details
Main Authors: Hsu, Tzu-Kun, 許慈坤
Other Authors: Chang, Kwo-Ping
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/5hv5h5
id ndltd-TW-105TCCN0605015
record_format oai_dc
spelling ndltd-TW-105TCCN06050152019-05-16T00:15:32Z http://ndltd.ncl.edu.tw/handle/5hv5h5 Dose evaluation of computed tomography in children abdomen with TLD 利用熱發光劑量計對小兒腹部電腻斷層攝影劑量評估 Hsu, Tzu-Kun 許慈坤 碩士 慈濟科技大學 放射醫學科學研究所 104 Abstract CT (computed tomography) is widely used in the clinical hospital of medical imaging, computer tomography is a fast, non-intrusive inspection equipment, but it is of Radiology in the highest dose of radiation instruments. The appropriate scanning parameters set, can obtain a good image quality and can reduce patient radiation dose. Radiation sensitivity of children than adults, so how to develop clinical scanning parameters are very important topic. In this study, the Ministry of Health and Welfare Department of Comparative respectively Taitung Hospital and successful branch of Radiology, computed tomography, the same brand TOSHIBA 80 Prosecution and device row CT (TSX-320A) with a single row of the Detects device CT (TSX-021B) during Pediatric prosthesis whole abdomen scan checks, changing the operating parameters of CT, including changing section width, the tube voltage and tube current effective effective parameters such as image resolution does not affect the diagnostic value of the parameter, the assessment of both the effective dose . Radiation dose measurement system using heat dosimeter TLD 100 (LiF) placed ATOM children leave the outer surface of the skin and internal organ dose measurements. In this study, clinical examination outside the parameters of CT scans, and two computer tomography to assess whether there is a viable parameters without affecting the diagnostic value of the case, again reducing the effective dose of the patient's dose as low as reasonably achievable best rule technology, according to the best of scanning parameters for future clinical use and give other hospitals use the same label as a reference model, and create a better quality of care and patient safety. Chang, Kwo-Ping 張國平 2016 學位論文 ; thesis 104 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 慈濟科技大學 === 放射醫學科學研究所 === 104 === Abstract CT (computed tomography) is widely used in the clinical hospital of medical imaging, computer tomography is a fast, non-intrusive inspection equipment, but it is of Radiology in the highest dose of radiation instruments. The appropriate scanning parameters set, can obtain a good image quality and can reduce patient radiation dose. Radiation sensitivity of children than adults, so how to develop clinical scanning parameters are very important topic. In this study, the Ministry of Health and Welfare Department of Comparative respectively Taitung Hospital and successful branch of Radiology, computed tomography, the same brand TOSHIBA 80 Prosecution and device row CT (TSX-320A) with a single row of the Detects device CT (TSX-021B) during Pediatric prosthesis whole abdomen scan checks, changing the operating parameters of CT, including changing section width, the tube voltage and tube current effective effective parameters such as image resolution does not affect the diagnostic value of the parameter, the assessment of both the effective dose . Radiation dose measurement system using heat dosimeter TLD 100 (LiF) placed ATOM children leave the outer surface of the skin and internal organ dose measurements. In this study, clinical examination outside the parameters of CT scans, and two computer tomography to assess whether there is a viable parameters without affecting the diagnostic value of the case, again reducing the effective dose of the patient's dose as low as reasonably achievable best rule technology, according to the best of scanning parameters for future clinical use and give other hospitals use the same label as a reference model, and create a better quality of care and patient safety.
author2 Chang, Kwo-Ping
author_facet Chang, Kwo-Ping
Hsu, Tzu-Kun
許慈坤
author Hsu, Tzu-Kun
許慈坤
spellingShingle Hsu, Tzu-Kun
許慈坤
Dose evaluation of computed tomography in children abdomen with TLD
author_sort Hsu, Tzu-Kun
title Dose evaluation of computed tomography in children abdomen with TLD
title_short Dose evaluation of computed tomography in children abdomen with TLD
title_full Dose evaluation of computed tomography in children abdomen with TLD
title_fullStr Dose evaluation of computed tomography in children abdomen with TLD
title_full_unstemmed Dose evaluation of computed tomography in children abdomen with TLD
title_sort dose evaluation of computed tomography in children abdomen with tld
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/5hv5h5
work_keys_str_mv AT hsutzukun doseevaluationofcomputedtomographyinchildrenabdomenwithtld
AT xǔcíkūn doseevaluationofcomputedtomographyinchildrenabdomenwithtld
AT hsutzukun lìyòngrèfāguāngjìliàngjìduìxiǎoérfùbùdiànnìduàncéngshèyǐngjìliàngpínggū
AT xǔcíkūn lìyòngrèfāguāngjìliàngjìduìxiǎoérfùbùdiànnìduàncéngshèyǐngjìliàngpínggū
_version_ 1719162797910130688