The development of simplified calculation method for average glandular dose in mammography

碩士 === 中山醫學大學 === 醫學影像暨放射科學系碩士班 === 106 === Introduction Estimation of average glandular dose (AGD) is an important issue in mammography. The AGD calculation method is complicate due to the fact that the compressed breast thickness (CBT) and percentage glandular content (PGC) have to be known. The p...

Full description

Bibliographic Details
Main Authors: Yu-Ting Chao, 趙俞婷
Other Authors: Shang-Lung Dong
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/8g6hmp
id ndltd-TW-106CSMU5770004
record_format oai_dc
spelling ndltd-TW-106CSMU57700042019-05-16T01:31:55Z http://ndltd.ncl.edu.tw/handle/8g6hmp The development of simplified calculation method for average glandular dose in mammography 對乳房攝影之平均乳腺劑量發展簡化的計算方法 Yu-Ting Chao 趙俞婷 碩士 中山醫學大學 醫學影像暨放射科學系碩士班 106 Introduction Estimation of average glandular dose (AGD) is an important issue in mammography. The AGD calculation method is complicate due to the fact that the compressed breast thickness (CBT) and percentage glandular content (PGC) have to be known. The purpose of this study is to develop the simplified AGD calculation method using equivalent thickness breast model (ET-BM). Material and methods The first step in this study is the development of simplified AGD calculation method using ET-BM. The second step is the verification of the ET-BM AGD calculation method using rigid phantoms with different thicknesses (2~6 cm) and compositions (PGC=0~100%). The third step is the estimation of the AGD of different compressible breast phantoms with the ET-BM AGD calculation method in Full field digital mammography (FFDM) procedure. The last step is the estimation of the AGD of different compressible breast phantoms with the ET-BM AGD calculation method in Digital breast tomosynthesis (DBT) procedure. Results Results from this study show that the error of AGD of rigid phantoms calculated using the ET-BM AGD calculation method ranging from -0.07~0.25 mGy. The values of root-mean-square errors (RMSE) on AGD for different compressible breast phantoms are 0.03~0.07 mGy in different FFDM systems. The value of RMSE on AGD for different compressible breast phantoms is 0.08 mGy in DBT procedure. Conclusion The ET-BM AGD calculation method proposed in this study can estimate AGD using imaging factors while without information about CBT and PGC in mammography. By applying the ET-BM AGD calculation method, the accuracy of AGD is acceptable in clinical practice. This method is suitable for rapidly AGD estimation in mammography. Shang-Lung Dong 董尚倫 2018 學位論文 ; thesis 136 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中山醫學大學 === 醫學影像暨放射科學系碩士班 === 106 === Introduction Estimation of average glandular dose (AGD) is an important issue in mammography. The AGD calculation method is complicate due to the fact that the compressed breast thickness (CBT) and percentage glandular content (PGC) have to be known. The purpose of this study is to develop the simplified AGD calculation method using equivalent thickness breast model (ET-BM). Material and methods The first step in this study is the development of simplified AGD calculation method using ET-BM. The second step is the verification of the ET-BM AGD calculation method using rigid phantoms with different thicknesses (2~6 cm) and compositions (PGC=0~100%). The third step is the estimation of the AGD of different compressible breast phantoms with the ET-BM AGD calculation method in Full field digital mammography (FFDM) procedure. The last step is the estimation of the AGD of different compressible breast phantoms with the ET-BM AGD calculation method in Digital breast tomosynthesis (DBT) procedure. Results Results from this study show that the error of AGD of rigid phantoms calculated using the ET-BM AGD calculation method ranging from -0.07~0.25 mGy. The values of root-mean-square errors (RMSE) on AGD for different compressible breast phantoms are 0.03~0.07 mGy in different FFDM systems. The value of RMSE on AGD for different compressible breast phantoms is 0.08 mGy in DBT procedure. Conclusion The ET-BM AGD calculation method proposed in this study can estimate AGD using imaging factors while without information about CBT and PGC in mammography. By applying the ET-BM AGD calculation method, the accuracy of AGD is acceptable in clinical practice. This method is suitable for rapidly AGD estimation in mammography.
author2 Shang-Lung Dong
author_facet Shang-Lung Dong
Yu-Ting Chao
趙俞婷
author Yu-Ting Chao
趙俞婷
spellingShingle Yu-Ting Chao
趙俞婷
The development of simplified calculation method for average glandular dose in mammography
author_sort Yu-Ting Chao
title The development of simplified calculation method for average glandular dose in mammography
title_short The development of simplified calculation method for average glandular dose in mammography
title_full The development of simplified calculation method for average glandular dose in mammography
title_fullStr The development of simplified calculation method for average glandular dose in mammography
title_full_unstemmed The development of simplified calculation method for average glandular dose in mammography
title_sort development of simplified calculation method for average glandular dose in mammography
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/8g6hmp
work_keys_str_mv AT yutingchao thedevelopmentofsimplifiedcalculationmethodforaverageglandulardoseinmammography
AT zhàoyútíng thedevelopmentofsimplifiedcalculationmethodforaverageglandulardoseinmammography
AT yutingchao duìrǔfángshèyǐngzhīpíngjūnrǔxiànjìliàngfāzhǎnjiǎnhuàdejìsuànfāngfǎ
AT zhàoyútíng duìrǔfángshèyǐngzhīpíngjūnrǔxiànjìliàngfāzhǎnjiǎnhuàdejìsuànfāngfǎ
AT yutingchao developmentofsimplifiedcalculationmethodforaverageglandulardoseinmammography
AT zhàoyútíng developmentofsimplifiedcalculationmethodforaverageglandulardoseinmammography
_version_ 1719176579189309440