Implementation of Wristband PPG Heart Rate Variation Monitor

碩士 === 國立虎尾科技大學 === 光電工程系光電與材料科技碩士班 === 106 === The PPG (Photoplethysmogram) was used to measure the heart rate variability (HRV) measurement signal. The low-power microprocessor Holtek HT66F70A captured the heartbeat interval per unit time of the PPG signal and used low power. Spending Bluetooth 4....

Full description

Bibliographic Details
Main Authors: HUANG, JYUN-YING, 黃俊穎
Other Authors: KUO, WEN-KAI
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/aehsyg
id ndltd-TW-106NYPI0124035
record_format oai_dc
spelling ndltd-TW-106NYPI01240352019-05-16T00:44:55Z http://ndltd.ncl.edu.tw/handle/aehsyg Implementation of Wristband PPG Heart Rate Variation Monitor 手環式PPG心率變異監測儀開發 HUANG, JYUN-YING 黃俊穎 碩士 國立虎尾科技大學 光電工程系光電與材料科技碩士班 106 The PPG (Photoplethysmogram) was used to measure the heart rate variability (HRV) measurement signal. The low-power microprocessor Holtek HT66F70A captured the heartbeat interval per unit time of the PPG signal and used low power. Spending Bluetooth 4.0 sends the measurement data to the APP of the mobile phone for calculations to observe the rate of heart rate variation and changes in parasympathetic nerves. The lightweight and power consumption make it easy to carry and monitor its current physiological condition at any time. The micro-processing chip used is the Holtek HT66F70A whose memory is 2048 Byte and contains 12 Bit A/D for the monitoring system to intercept the heart rate signal. The relevant measurement signal is set as the sampling period of 146.4 ms which is equivalent to the sampling frequency of 6.82 Hz, and the number of samples is once. Measurement period is 5 minutes (2048 times). The microprocessor performs heartbeat R-wave interval measurement and then uses the Berger's algorithm to find the heart rate equidistant waveforms. After that, the result of the calculation is the UART protocol, from the low-power Bluetooth 4.0. The calculation data is transmitted to the mobile phone for heart rate analysis and spectrum conversion. After calculation, the display items include: TP (total power), HF (high frequency power), LF (low frequency power), LF/HF (low-frequency power ratio) .。 KUO, WEN-KAI CHEN, SHEN-YAUR 郭文凱 陳慎銚 2018 學位論文 ; thesis 60 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立虎尾科技大學 === 光電工程系光電與材料科技碩士班 === 106 === The PPG (Photoplethysmogram) was used to measure the heart rate variability (HRV) measurement signal. The low-power microprocessor Holtek HT66F70A captured the heartbeat interval per unit time of the PPG signal and used low power. Spending Bluetooth 4.0 sends the measurement data to the APP of the mobile phone for calculations to observe the rate of heart rate variation and changes in parasympathetic nerves. The lightweight and power consumption make it easy to carry and monitor its current physiological condition at any time. The micro-processing chip used is the Holtek HT66F70A whose memory is 2048 Byte and contains 12 Bit A/D for the monitoring system to intercept the heart rate signal. The relevant measurement signal is set as the sampling period of 146.4 ms which is equivalent to the sampling frequency of 6.82 Hz, and the number of samples is once. Measurement period is 5 minutes (2048 times). The microprocessor performs heartbeat R-wave interval measurement and then uses the Berger's algorithm to find the heart rate equidistant waveforms. After that, the result of the calculation is the UART protocol, from the low-power Bluetooth 4.0. The calculation data is transmitted to the mobile phone for heart rate analysis and spectrum conversion. After calculation, the display items include: TP (total power), HF (high frequency power), LF (low frequency power), LF/HF (low-frequency power ratio) .。
author2 KUO, WEN-KAI
author_facet KUO, WEN-KAI
HUANG, JYUN-YING
黃俊穎
author HUANG, JYUN-YING
黃俊穎
spellingShingle HUANG, JYUN-YING
黃俊穎
Implementation of Wristband PPG Heart Rate Variation Monitor
author_sort HUANG, JYUN-YING
title Implementation of Wristband PPG Heart Rate Variation Monitor
title_short Implementation of Wristband PPG Heart Rate Variation Monitor
title_full Implementation of Wristband PPG Heart Rate Variation Monitor
title_fullStr Implementation of Wristband PPG Heart Rate Variation Monitor
title_full_unstemmed Implementation of Wristband PPG Heart Rate Variation Monitor
title_sort implementation of wristband ppg heart rate variation monitor
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/aehsyg
work_keys_str_mv AT huangjyunying implementationofwristbandppgheartratevariationmonitor
AT huángjùnyǐng implementationofwristbandppgheartratevariationmonitor
AT huangjyunying shǒuhuánshìppgxīnlǜbiànyìjiāncèyíkāifā
AT huángjùnyǐng shǒuhuánshìppgxīnlǜbiànyìjiāncèyíkāifā
_version_ 1719170995399426048