Evaluation of radiation dose distribution on Fluoroscopy

碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 107 === The Atomic Enengy Council (AEC) conducted a programme to maitain the quality image under fluoroscopy since 2018. The medical staffs including radiologist, radiographer, assisted nurse are invesitable exposed to the radiation. The dose distribution depends...

Full description

Bibliographic Details
Main Authors: XIAO,YU-JIE, 蕭郁潔
Other Authors: LIN,CHENG-HSUN
Format: Others
Language:zh-TW
Published: 2019
Online Access:http://ndltd.ncl.edu.tw/handle/25m3x7
id ndltd-TW-107CTC00770001
record_format oai_dc
spelling ndltd-TW-107CTC007700012019-08-22T04:01:08Z http://ndltd.ncl.edu.tw/handle/25m3x7 Evaluation of radiation dose distribution on Fluoroscopy 以空間矩陣法探討透視攝影空間輻射劑量分佈 XIAO,YU-JIE 蕭郁潔 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 107 The Atomic Enengy Council (AEC) conducted a programme to maitain the quality image under fluoroscopy since 2018. The medical staffs including radiologist, radiographer, assisted nurse are invesitable exposed to the radiation. The dose distribution depends on the location in the room, different kind of modalities, and the dose protocols.   78 TLD-100H (Harshaw, USA) were allocated in the matrix of space of 300×180 cm². Seven cotton threads were fixed on a pole with both ends, 11 TLDs were set at a distance of 30cm equally. Thus, 77 TLDS were allocated at one level. Five levels were set at 85cm, 95cm, 125cm, 155cm, and 180cm from floor to measure the radiation in a room undergoing fluoroscopy. Three models wore apron and simulated the standard position in a room to simulate regular examinations. Each level were exposed three time for justifications. Fluoroscopic time were set respectively at 10sec, 20sec, 30sec, 60sec, 90sec, 120sec, and 150sec.   The average dose from first level to the fifth one respectively of 1.46±0.45mGy、1.54±0.69 mGy、2.12±0.82 mGy、1.42±0.56 mGy、1.36±0.38 mGy。According to the result, the average dose at 125cm reaches highest dose but still lower than the allowance of the regulation in Taiwan. Aside from this findings, one result was suggested that medical staffs would also be a source of scatter radiation during fluoroscopy, a 30 cm between two staffs was suggested accordingly. LIN,CHENG-HSUN 林政勳 2019 學位論文 ; thesis 97 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 107 === The Atomic Enengy Council (AEC) conducted a programme to maitain the quality image under fluoroscopy since 2018. The medical staffs including radiologist, radiographer, assisted nurse are invesitable exposed to the radiation. The dose distribution depends on the location in the room, different kind of modalities, and the dose protocols.   78 TLD-100H (Harshaw, USA) were allocated in the matrix of space of 300×180 cm². Seven cotton threads were fixed on a pole with both ends, 11 TLDs were set at a distance of 30cm equally. Thus, 77 TLDS were allocated at one level. Five levels were set at 85cm, 95cm, 125cm, 155cm, and 180cm from floor to measure the radiation in a room undergoing fluoroscopy. Three models wore apron and simulated the standard position in a room to simulate regular examinations. Each level were exposed three time for justifications. Fluoroscopic time were set respectively at 10sec, 20sec, 30sec, 60sec, 90sec, 120sec, and 150sec.   The average dose from first level to the fifth one respectively of 1.46±0.45mGy、1.54±0.69 mGy、2.12±0.82 mGy、1.42±0.56 mGy、1.36±0.38 mGy。According to the result, the average dose at 125cm reaches highest dose but still lower than the allowance of the regulation in Taiwan. Aside from this findings, one result was suggested that medical staffs would also be a source of scatter radiation during fluoroscopy, a 30 cm between two staffs was suggested accordingly.
author2 LIN,CHENG-HSUN
author_facet LIN,CHENG-HSUN
XIAO,YU-JIE
蕭郁潔
author XIAO,YU-JIE
蕭郁潔
spellingShingle XIAO,YU-JIE
蕭郁潔
Evaluation of radiation dose distribution on Fluoroscopy
author_sort XIAO,YU-JIE
title Evaluation of radiation dose distribution on Fluoroscopy
title_short Evaluation of radiation dose distribution on Fluoroscopy
title_full Evaluation of radiation dose distribution on Fluoroscopy
title_fullStr Evaluation of radiation dose distribution on Fluoroscopy
title_full_unstemmed Evaluation of radiation dose distribution on Fluoroscopy
title_sort evaluation of radiation dose distribution on fluoroscopy
publishDate 2019
url http://ndltd.ncl.edu.tw/handle/25m3x7
work_keys_str_mv AT xiaoyujie evaluationofradiationdosedistributiononfluoroscopy
AT xiāoyùjié evaluationofradiationdosedistributiononfluoroscopy
AT xiaoyujie yǐkōngjiānjǔzhènfǎtàntǎotòushìshèyǐngkōngjiānfúshèjìliàngfēnbù
AT xiāoyùjié yǐkōngjiānjǔzhènfǎtàntǎotòushìshèyǐngkōngjiānfúshèjìliàngfēnbù
_version_ 1719236360789819392