Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation

碩士 === 國立高雄科技大學 === 電機工程系 === 107 === Substation is a very important part of Power Supply System. To ensure of the quality of the supplied power and safety of the staff member, it is necessary to have a well-designed grounding system. If the actual mesh voltage and step voltage generated by the elec...

Full description

Bibliographic Details
Main Authors: CHENG,MING-FANG, 鄭茗方
Other Authors: CHO,MING-YUAN
Format: Others
Language:zh-TW
Published: 2019
Online Access:http://ndltd.ncl.edu.tw/handle/p9s8ak
id ndltd-TW-107NKUS0442020
record_format oai_dc
spelling ndltd-TW-107NKUS04420202019-08-15T03:37:55Z http://ndltd.ncl.edu.tw/handle/p9s8ak Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation 屋內式超高壓變電所筏基下地網之接地安全分析 CHENG,MING-FANG 鄭茗方 碩士 國立高雄科技大學 電機工程系 107 Substation is a very important part of Power Supply System. To ensure of the quality of the supplied power and safety of the staff member, it is necessary to have a well-designed grounding system. If the actual mesh voltage and step voltage generated by the electrical substation is lower than the permissible touch and step voltage, and tolerable shock duration is higher than the fault clearing time, it means the grounding system of the electrical substation is safe. This thesis is based on the following standard and software to run the calculation and simulation:IEEE Std.80,2000 - IEEE Guide for safety in AC substation grounding、Finite Element Analysis of ETAP and MATLAB . And then to analyze that the actual mesh voltage and step voltage generated by the electrical substation is lower than the permissible touch voltage with/without ground grid and ground rod under Raft foundation for an Extra High Voltage Substation. Furthermore, by comparing with soil resistivity, surface layer resistivity, depth and range interval of ground grid conductors, quantities of ground rod and shock duration affect permissible touch to simulate effort of safety under two kind grounding type. This study can provide a reference for the Taipower on dealing with similar cases. CHO,MING-YUAN 卓明遠 2019 學位論文 ; thesis 102 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄科技大學 === 電機工程系 === 107 === Substation is a very important part of Power Supply System. To ensure of the quality of the supplied power and safety of the staff member, it is necessary to have a well-designed grounding system. If the actual mesh voltage and step voltage generated by the electrical substation is lower than the permissible touch and step voltage, and tolerable shock duration is higher than the fault clearing time, it means the grounding system of the electrical substation is safe. This thesis is based on the following standard and software to run the calculation and simulation:IEEE Std.80,2000 - IEEE Guide for safety in AC substation grounding、Finite Element Analysis of ETAP and MATLAB . And then to analyze that the actual mesh voltage and step voltage generated by the electrical substation is lower than the permissible touch voltage with/without ground grid and ground rod under Raft foundation for an Extra High Voltage Substation. Furthermore, by comparing with soil resistivity, surface layer resistivity, depth and range interval of ground grid conductors, quantities of ground rod and shock duration affect permissible touch to simulate effort of safety under two kind grounding type. This study can provide a reference for the Taipower on dealing with similar cases.
author2 CHO,MING-YUAN
author_facet CHO,MING-YUAN
CHENG,MING-FANG
鄭茗方
author CHENG,MING-FANG
鄭茗方
spellingShingle CHENG,MING-FANG
鄭茗方
Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
author_sort CHENG,MING-FANG
title Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
title_short Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
title_full Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
title_fullStr Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
title_full_unstemmed Grounding Safety Analysis of Indoor Extra High Voltage Substations Under Raft Foundation
title_sort grounding safety analysis of indoor extra high voltage substations under raft foundation
publishDate 2019
url http://ndltd.ncl.edu.tw/handle/p9s8ak
work_keys_str_mv AT chengmingfang groundingsafetyanalysisofindoorextrahighvoltagesubstationsunderraftfoundation
AT zhèngmíngfāng groundingsafetyanalysisofindoorextrahighvoltagesubstationsunderraftfoundation
AT chengmingfang wūnèishìchāogāoyābiàndiànsuǒfájīxiàdewǎngzhījiēdeānquánfēnxī
AT zhèngmíngfāng wūnèishìchāogāoyābiàndiànsuǒfájīxiàdewǎngzhījiēdeānquánfēnxī
_version_ 1719234861993033728