Triangular Current Mode Totem-Pole Bridgeless PFC Converter without ZCD circuit

碩士 === 國立臺灣科技大學 === 電子工程系 === 107 === This thesis presents a triangular current mode totem-pole PFC rectifier with variable frequency. It can achievd ZVS over the full input voltage range. This thesis proposes a triangular current-mode control without an external zero current detection circuit. In t...

Full description

Bibliographic Details
Main Authors: Wei-Lun Chen, 陳偉倫
Other Authors: Huang-Jen Chiu
Format: Others
Language:zh-TW
Published: 2019
Online Access:http://ndltd.ncl.edu.tw/handle/qgwrhg
Description
Summary:碩士 === 國立臺灣科技大學 === 電子工程系 === 107 === This thesis presents a triangular current mode totem-pole PFC rectifier with variable frequency. It can achievd ZVS over the full input voltage range. This thesis proposes a triangular current-mode control without an external zero current detection circuit. In this thesis, average current-mode control is used to achived high power factor. The period of the duty cycle is calculated using the average current reference, input voltage, and output voltage. PSIM simulation is utilized to verify the feasibility of the proposed control method. Finally, the 800-W bridgeless TPPFC with the proposed control is implemented with the switch frequency around 60 kHz-180kHz, an input voltage of 230 Vrms, and an output voltage of 400 V. The maximum experimental efficiency is 98.02%. Keywords: Triangular Current Mode, ZVS, Totem-pole PFC, average current control, zero current detection circuit