Towards real time EMG analysis

Techniques for automatic recording and analyzing single motor unit action potentials in real time have been studied. A model of the human motor unit has been derived. The muscle fibers were modelled with current dipoles and randomly distributed within the motor unit cross section according to a biva...

Full description

Bibliographic Details
Main Author: Kenward, Gary Wayne
Language:English
Published: 2010
Online Access:http://hdl.handle.net/2429/23428
id ndltd-UBC-oai-circle.library.ubc.ca-2429-23428
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-234282018-01-05T17:42:11Z Towards real time EMG analysis Kenward, Gary Wayne Techniques for automatic recording and analyzing single motor unit action potentials in real time have been studied. A model of the human motor unit has been derived. The muscle fibers were modelled with current dipoles and randomly distributed within the motor unit cross section according to a bivariate Gaussian, or binormal, probability density function. Computer simulations were performed with the model using parameters measured for the human biceps brachii. The single fiber action potentials generated by the current dipoles were summed at a recording site to produce a simulated single motor unit action potential. Analysis of the motor unit model and the potentials generated showed that the single motor unit action potentials of interest were recorded from well within the motor unit territory, and that the potentials formed were influenced mainly by the nearby fibers. The single motor unit action potential amplitude and duration were found to have a non-linear dependence upon the radius of the recording site from the motor unit center. The relationship between amplitude and duration was found to be linear but subject to random variations due to the influence of nearby fibers. The behaviour of the simulated single motor unit action potentials agreed with clinical observations. A three stage real time processing system was designed. The signal characteristics of clinically recorded electromyographic activity at low contraction levels were analyzed, and the first stage of pre-filtering designed to reduce the required sampling rate, and increase the signal to noise ratio without distorting the single motor unit action potentials. The second stage of processing was based on an adaptive matched filter with dual detection thresholds. The final stage used feature classification of the detected single motor unit action potentials to remove potentials not from the selected motor unit. A non-real time software implementation of the processing system demonstrated that large ensembles of single motor unit action potentials could be acquired from relatively short recordings of electromyographic activity, with few detection errors. Applied Science, Faculty of Electrical and Computer Engineering, Department of Graduate 2010-04-13T15:33:21Z 2010-04-13T15:33:21Z 1982 Text Thesis/Dissertation http://hdl.handle.net/2429/23428 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
collection NDLTD
language English
sources NDLTD
description Techniques for automatic recording and analyzing single motor unit action potentials in real time have been studied. A model of the human motor unit has been derived. The muscle fibers were modelled with current dipoles and randomly distributed within the motor unit cross section according to a bivariate Gaussian, or binormal, probability density function. Computer simulations were performed with the model using parameters measured for the human biceps brachii. The single fiber action potentials generated by the current dipoles were summed at a recording site to produce a simulated single motor unit action potential. Analysis of the motor unit model and the potentials generated showed that the single motor unit action potentials of interest were recorded from well within the motor unit territory, and that the potentials formed were influenced mainly by the nearby fibers. The single motor unit action potential amplitude and duration were found to have a non-linear dependence upon the radius of the recording site from the motor unit center. The relationship between amplitude and duration was found to be linear but subject to random variations due to the influence of nearby fibers. The behaviour of the simulated single motor unit action potentials agreed with clinical observations. A three stage real time processing system was designed. The signal characteristics of clinically recorded electromyographic activity at low contraction levels were analyzed, and the first stage of pre-filtering designed to reduce the required sampling rate, and increase the signal to noise ratio without distorting the single motor unit action potentials. The second stage of processing was based on an adaptive matched filter with dual detection thresholds. The final stage used feature classification of the detected single motor unit action potentials to remove potentials not from the selected motor unit. A non-real time software implementation of the processing system demonstrated that large ensembles of single motor unit action potentials could be acquired from relatively short recordings of electromyographic activity, with few detection errors. === Applied Science, Faculty of === Electrical and Computer Engineering, Department of === Graduate
author Kenward, Gary Wayne
spellingShingle Kenward, Gary Wayne
Towards real time EMG analysis
author_facet Kenward, Gary Wayne
author_sort Kenward, Gary Wayne
title Towards real time EMG analysis
title_short Towards real time EMG analysis
title_full Towards real time EMG analysis
title_fullStr Towards real time EMG analysis
title_full_unstemmed Towards real time EMG analysis
title_sort towards real time emg analysis
publishDate 2010
url http://hdl.handle.net/2429/23428
work_keys_str_mv AT kenwardgarywayne towardsrealtimeemganalysis
_version_ 1718592299874648064