Flow injection hydride generation atomic absorption spectrometry

Flow injection hydride generation atomic absorption spectrometry is the practice of derivatizing the analyte to the volatile hydride by flow injection and introducing it to the spectrometer in the gas phase. Although hydride generation is well developed, there are still aspects and nuances which req...

Full description

Bibliographic Details
Main Author: Ellis, Robert Ian
Language:ENG
Published: ScholarWorks@UMass Amherst 1998
Subjects:
Online Access:https://scholarworks.umass.edu/dissertations/AAI9823732
id ndltd-UMASS-oai-scholarworks.umass.edu-dissertations-2985
record_format oai_dc
spelling ndltd-UMASS-oai-scholarworks.umass.edu-dissertations-29852020-12-02T14:34:37Z Flow injection hydride generation atomic absorption spectrometry Ellis, Robert Ian Flow injection hydride generation atomic absorption spectrometry is the practice of derivatizing the analyte to the volatile hydride by flow injection and introducing it to the spectrometer in the gas phase. Although hydride generation is well developed, there are still aspects and nuances which require investigation to improve the understanding of this method of sample introduction. The suggestion that the addition of various surfactants to the reagents in the hydride forming reaction has beneficial effects has been investigated. Although, in previous reports, an increase in sensitivity had been reported in the presence of surfactants, such an improvement was not observed for the flow injection procedure used in the work described in this dissertation. The effect of dissolved salts on the hydride forming reaction has been investigated. An increase in sensitivity in the presence of high concentrations of dissolved salts has been observed. This has been attributed to an increase in the proportion of the volatile hydride which is removed from the reagents in the on-line procedure. In the hydride trapping procedure, the hydrides are trapped on the interior of an electrothermal atomizer prior to atomization. Although previous reports have indicated that one may improve the limit of detection simply by increasing sample size, a practical and theoretical investigation concluded that the relationship is not linear, and that the limit of detection is limited by impurities in the reagents. Methods for the determination of lead by hydride generation with quartz tube and electrothermal atomization have been developed. The use of an oxidizing agent makes this method a little more complicated than for other elements. The determination of total selenium in urine has been attempted using an on-line digestion procedure in which bromine is generated in-situ. Whilst this method has been demonstrated to be effective in an off-line procedure, the development of a method with on-line digestion was not successful. The use of an alternative oxidizing agent and energy supply mechanism would be appear to be necessary. 1998-01-01T08:00:00Z text https://scholarworks.umass.edu/dissertations/AAI9823732 Doctoral Dissertations Available from Proquest ENG ScholarWorks@UMass Amherst Analytical chemistry
collection NDLTD
language ENG
sources NDLTD
topic Analytical chemistry
spellingShingle Analytical chemistry
Ellis, Robert Ian
Flow injection hydride generation atomic absorption spectrometry
description Flow injection hydride generation atomic absorption spectrometry is the practice of derivatizing the analyte to the volatile hydride by flow injection and introducing it to the spectrometer in the gas phase. Although hydride generation is well developed, there are still aspects and nuances which require investigation to improve the understanding of this method of sample introduction. The suggestion that the addition of various surfactants to the reagents in the hydride forming reaction has beneficial effects has been investigated. Although, in previous reports, an increase in sensitivity had been reported in the presence of surfactants, such an improvement was not observed for the flow injection procedure used in the work described in this dissertation. The effect of dissolved salts on the hydride forming reaction has been investigated. An increase in sensitivity in the presence of high concentrations of dissolved salts has been observed. This has been attributed to an increase in the proportion of the volatile hydride which is removed from the reagents in the on-line procedure. In the hydride trapping procedure, the hydrides are trapped on the interior of an electrothermal atomizer prior to atomization. Although previous reports have indicated that one may improve the limit of detection simply by increasing sample size, a practical and theoretical investigation concluded that the relationship is not linear, and that the limit of detection is limited by impurities in the reagents. Methods for the determination of lead by hydride generation with quartz tube and electrothermal atomization have been developed. The use of an oxidizing agent makes this method a little more complicated than for other elements. The determination of total selenium in urine has been attempted using an on-line digestion procedure in which bromine is generated in-situ. Whilst this method has been demonstrated to be effective in an off-line procedure, the development of a method with on-line digestion was not successful. The use of an alternative oxidizing agent and energy supply mechanism would be appear to be necessary.
author Ellis, Robert Ian
author_facet Ellis, Robert Ian
author_sort Ellis, Robert Ian
title Flow injection hydride generation atomic absorption spectrometry
title_short Flow injection hydride generation atomic absorption spectrometry
title_full Flow injection hydride generation atomic absorption spectrometry
title_fullStr Flow injection hydride generation atomic absorption spectrometry
title_full_unstemmed Flow injection hydride generation atomic absorption spectrometry
title_sort flow injection hydride generation atomic absorption spectrometry
publisher ScholarWorks@UMass Amherst
publishDate 1998
url https://scholarworks.umass.edu/dissertations/AAI9823732
work_keys_str_mv AT ellisrobertian flowinjectionhydridegenerationatomicabsorptionspectrometry
_version_ 1719364699862073344