The Effects of Surge Flows on Residential Water Meters
All residential water meters have published flow rates for which they will operate as designed. These specifications include a maximum operating flow rate, which is recommended not to exceed. However, there are situations which may cause a meter to flow above the maximum flow rate. This thesis explo...
Main Author: | |
---|---|
Format: | Others |
Published: |
DigitalCommons@USU
2018
|
Subjects: | |
Online Access: | https://digitalcommons.usu.edu/etd/7042 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=8149&context=etd |
id |
ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-8149 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-81492019-10-13T05:32:25Z The Effects of Surge Flows on Residential Water Meters Weller, Ryan P All residential water meters have published flow rates for which they will operate as designed. These specifications include a maximum operating flow rate, which is recommended not to exceed. However, there are situations which may cause a meter to flow above the maximum flow rate. This thesis explores what effect these surge flows have on residential water meters. Twenty-one 5/8”x3/4” meters were tested in this study: three oscillating pistons, six nutating disks, nine ultrasonic, and three electromagnetic. Testing was done at the Utah Water Research Laboratory using a gravimetric test bench specifically designed for residential water meter testing. The results of this study showed that the ultrasonic meters decreased significantly in accuracy for tests above 35 gallons per minute. The nutating disk and oscillating piston meters were found to be accurate through nearly all surge flow rates tested. The electromagnetic meters were found to be accurate up to 55gallons per minute. Accuracy tests that were performed after surge flows showed that some nutating disk and oscillating piston meters decreased in accuracy at flow rates below two gallons per minute. The electronic meters had similar accuracy before and after surge flows. 2018-05-01T07:00:00Z text application/pdf https://digitalcommons.usu.edu/etd/7042 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=8149&context=etd Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu. All Graduate Theses and Dissertations DigitalCommons@USU Pressure Loss Accuracy Residential Water Meters Surge Civil and Environmental Engineering Engineering |
collection |
NDLTD |
format |
Others
|
sources |
NDLTD |
topic |
Pressure Loss Accuracy Residential Water Meters Surge Civil and Environmental Engineering Engineering |
spellingShingle |
Pressure Loss Accuracy Residential Water Meters Surge Civil and Environmental Engineering Engineering Weller, Ryan P The Effects of Surge Flows on Residential Water Meters |
description |
All residential water meters have published flow rates for which they will operate as designed. These specifications include a maximum operating flow rate, which is recommended not to exceed. However, there are situations which may cause a meter to flow above the maximum flow rate. This thesis explores what effect these surge flows have on residential water meters.
Twenty-one 5/8”x3/4” meters were tested in this study: three oscillating pistons, six nutating disks, nine ultrasonic, and three electromagnetic. Testing was done at the Utah Water Research Laboratory using a gravimetric test bench specifically designed for residential water meter testing.
The results of this study showed that the ultrasonic meters decreased significantly in accuracy for tests above 35 gallons per minute. The nutating disk and oscillating piston meters were found to be accurate through nearly all surge flow rates tested. The electromagnetic meters were found to be accurate up to 55gallons per minute.
Accuracy tests that were performed after surge flows showed that some nutating disk and oscillating piston meters decreased in accuracy at flow rates below two gallons per minute. The electronic meters had similar accuracy before and after surge flows. |
author |
Weller, Ryan P |
author_facet |
Weller, Ryan P |
author_sort |
Weller, Ryan P |
title |
The Effects of Surge Flows on Residential Water Meters |
title_short |
The Effects of Surge Flows on Residential Water Meters |
title_full |
The Effects of Surge Flows on Residential Water Meters |
title_fullStr |
The Effects of Surge Flows on Residential Water Meters |
title_full_unstemmed |
The Effects of Surge Flows on Residential Water Meters |
title_sort |
effects of surge flows on residential water meters |
publisher |
DigitalCommons@USU |
publishDate |
2018 |
url |
https://digitalcommons.usu.edu/etd/7042 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=8149&context=etd |
work_keys_str_mv |
AT wellerryanp theeffectsofsurgeflowsonresidentialwatermeters AT wellerryanp effectsofsurgeflowsonresidentialwatermeters |
_version_ |
1719266198786408448 |