Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible

Bilateral mandibular ostectomies were performed between premolars 3 and 4 in 10 adult canine specimens. A type I external fixator incorporating a full interdental pin was placed stabilizing a 0.5 cm fracture gap. Four different pin configurations were tested in dorsoventral bending five separate t...

Full description

Bibliographic Details
Main Author: Cook, Wesley Todd
Other Authors: Veterinary Medical Sciences
Format: Others
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/33683
http://scholar.lib.vt.edu/theses/available/etd-06222000-22500037/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-33683
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-336832020-09-29T05:46:47Z Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible Cook, Wesley Todd Veterinary Medical Sciences Smith, Mark M. Shires, Peter K. Markel, Mark Grant, Wallace External Skeletal Fixation Mandible and Fracture Keywords: Canine Bilateral mandibular ostectomies were performed between premolars 3 and 4 in 10 adult canine specimens. A type I external fixator incorporating a full interdental pin was placed stabilizing a 0.5 cm fracture gap. Four different pin configurations were tested in dorsoventral bending five separate times on each of the ten mandibles: 1) intact mandibular bodies with fixator; 2) ostectomized mandibular bodies and complete fixator; 3) ostectomized mandibular bodies with the caudal pins of the rostral fragment cut; 4) ostectomized mandibular bodies with all pins of the rostral fragment cut. The full interdental pin remained intact in all configurations. Total stiffness and gap stiffness were then determined for each fixation geometry on a materials testing machine. The mean total stiffness(Nm/rads) for the four configurations was 1) 1543.6, 2) 301.6, 3) 290.5, 4) 267.0. The mean gap stiffness(Nm/rads) for the right hemimandible was: 2) 2041.1, 3) 1763.5, 4) 1679.9. The mean gap stiffness of the left hemimandible was: 2) 2110.8, 3)1880.1, 4)1861.1. There was no gap stiffness for the first configuration since a fracture gap was not present. Two-way ANOVA was performed on the gap stiffness and the total stiffness. There was a significant decrease in total stiffness between intact mandibles and ostectomized mandibles regardless of external fixator configuration. However, there was not a significant difference in total stiffness or gap stiffness among the different external fixator configurations applied to ostectomized mandible. External fixator configurations with only the full interdental pin engaging the rostral fragment were as stiff as configurations which had two or four additional pins in the rostral fragment for the applied loads. External fixators for rostral mandibular fractures may be rigidly secured with rostral fragment implants applied extracortically avoiding iatrogenic trauma to teeth and tooth roots. Master of Science 2014-03-14T20:40:21Z 2014-03-14T20:40:21Z 2000-06-16 2000-06-22 2001-07-07 2000-07-07 Thesis etd-06222000-22500037 http://hdl.handle.net/10919/33683 http://scholar.lib.vt.edu/theses/available/etd-06222000-22500037/ Wescookl.PDF In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech
collection NDLTD
format Others
sources NDLTD
topic External Skeletal Fixation
Mandible and Fracture
Keywords: Canine
spellingShingle External Skeletal Fixation
Mandible and Fracture
Keywords: Canine
Cook, Wesley Todd
Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
description Bilateral mandibular ostectomies were performed between premolars 3 and 4 in 10 adult canine specimens. A type I external fixator incorporating a full interdental pin was placed stabilizing a 0.5 cm fracture gap. Four different pin configurations were tested in dorsoventral bending five separate times on each of the ten mandibles: 1) intact mandibular bodies with fixator; 2) ostectomized mandibular bodies and complete fixator; 3) ostectomized mandibular bodies with the caudal pins of the rostral fragment cut; 4) ostectomized mandibular bodies with all pins of the rostral fragment cut. The full interdental pin remained intact in all configurations. Total stiffness and gap stiffness were then determined for each fixation geometry on a materials testing machine. The mean total stiffness(Nm/rads) for the four configurations was 1) 1543.6, 2) 301.6, 3) 290.5, 4) 267.0. The mean gap stiffness(Nm/rads) for the right hemimandible was: 2) 2041.1, 3) 1763.5, 4) 1679.9. The mean gap stiffness of the left hemimandible was: 2) 2110.8, 3)1880.1, 4)1861.1. There was no gap stiffness for the first configuration since a fracture gap was not present. Two-way ANOVA was performed on the gap stiffness and the total stiffness. There was a significant decrease in total stiffness between intact mandibles and ostectomized mandibles regardless of external fixator configuration. However, there was not a significant difference in total stiffness or gap stiffness among the different external fixator configurations applied to ostectomized mandible. External fixator configurations with only the full interdental pin engaging the rostral fragment were as stiff as configurations which had two or four additional pins in the rostral fragment for the applied loads. External fixators for rostral mandibular fractures may be rigidly secured with rostral fragment implants applied extracortically avoiding iatrogenic trauma to teeth and tooth roots. === Master of Science
author2 Veterinary Medical Sciences
author_facet Veterinary Medical Sciences
Cook, Wesley Todd
author Cook, Wesley Todd
author_sort Cook, Wesley Todd
title Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
title_short Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
title_full Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
title_fullStr Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
title_full_unstemmed Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible
title_sort ex vivo biomechanics of a bilateral type i/bilateral interdental pin and acrylic external fixator applied to the canine mandible
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/33683
http://scholar.lib.vt.edu/theses/available/etd-06222000-22500037/
work_keys_str_mv AT cookwesleytodd exvivobiomechanicsofabilateraltypeibilateralinterdentalpinandacrylicexternalfixatorappliedtothecaninemandible
_version_ 1719346451828441088