Development of an electric heat pump for domestic use

This thesis records the design and development of an electrically driven, air to water, vapour compression heat pump of nominally 6kW heat output, for residential space heating. The study was carried out on behalf of GEC Research Ltd through the Interdisciplinary Higher Degrees Scheme at Aston Unive...

Full description

Bibliographic Details
Main Author: Crossman, D. R.
Published: Aston University 1986
Subjects:
697
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.235400
id ndltd-bl.uk-oai-ethos.bl.uk-235400
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-2354002017-04-20T03:25:35ZDevelopment of an electric heat pump for domestic useCrossman, D. R.1986This thesis records the design and development of an electrically driven, air to water, vapour compression heat pump of nominally 6kW heat output, for residential space heating. The study was carried out on behalf of GEC Research Ltd through the Interdisciplinary Higher Degrees Scheme at Aston University. A computer based mathematical model of the vapour compression cycle was produced as a design aid, to enable the effects of component design changes or variations in operating conditions to be predicted. This model is supported by performance testing of the major components, which revealed that improvements in the compressor isentropic efficiency offer the greatest potential for further increases in cycle COPh. The evaporator was designed from first principles, and is based on wire-wound heat transfer tubing. Two evaporators, of air side area 10.27 and 16.24m2, were tested in a temperature and humidity controlled environment, demonstrating that the benefits of the large coil are greater heat pump heat output and lower noise levels. A systematic study of frost growth rates suggested that this problem is most severe at the conditions of saturated air at 0oC combined with low condenser water temperature. A dynamic simulation model was developed to predict the in-service performance of the heat pump. This study confirmed the importance of an adequate radiator area for heat pump installations. A prototype heat pump was designed and manufactured, consisting of a hermetic reciprocating compressor, a coaxial tube condenser and a helically coiled evaporator, using Refrigerant 22. The prototype was field tested in a domestic environment for one and a half years. The installation included a comprehensive monitoring system. Initial problems were encountered with defrosting and compressor noise, both of which were solved. The unit then operated throughout the 1985/86 heating season without further attention, producing a COPh of 2.34.697Energy TechnologiesAston Universityhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.235400http://publications.aston.ac.uk/15144/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 697
Energy Technologies
spellingShingle 697
Energy Technologies
Crossman, D. R.
Development of an electric heat pump for domestic use
description This thesis records the design and development of an electrically driven, air to water, vapour compression heat pump of nominally 6kW heat output, for residential space heating. The study was carried out on behalf of GEC Research Ltd through the Interdisciplinary Higher Degrees Scheme at Aston University. A computer based mathematical model of the vapour compression cycle was produced as a design aid, to enable the effects of component design changes or variations in operating conditions to be predicted. This model is supported by performance testing of the major components, which revealed that improvements in the compressor isentropic efficiency offer the greatest potential for further increases in cycle COPh. The evaporator was designed from first principles, and is based on wire-wound heat transfer tubing. Two evaporators, of air side area 10.27 and 16.24m2, were tested in a temperature and humidity controlled environment, demonstrating that the benefits of the large coil are greater heat pump heat output and lower noise levels. A systematic study of frost growth rates suggested that this problem is most severe at the conditions of saturated air at 0oC combined with low condenser water temperature. A dynamic simulation model was developed to predict the in-service performance of the heat pump. This study confirmed the importance of an adequate radiator area for heat pump installations. A prototype heat pump was designed and manufactured, consisting of a hermetic reciprocating compressor, a coaxial tube condenser and a helically coiled evaporator, using Refrigerant 22. The prototype was field tested in a domestic environment for one and a half years. The installation included a comprehensive monitoring system. Initial problems were encountered with defrosting and compressor noise, both of which were solved. The unit then operated throughout the 1985/86 heating season without further attention, producing a COPh of 2.34.
author Crossman, D. R.
author_facet Crossman, D. R.
author_sort Crossman, D. R.
title Development of an electric heat pump for domestic use
title_short Development of an electric heat pump for domestic use
title_full Development of an electric heat pump for domestic use
title_fullStr Development of an electric heat pump for domestic use
title_full_unstemmed Development of an electric heat pump for domestic use
title_sort development of an electric heat pump for domestic use
publisher Aston University
publishDate 1986
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.235400
work_keys_str_mv AT crossmandr developmentofanelectricheatpumpfordomesticuse
_version_ 1718440296571731968