Electrochemical analysis supported by macro and microelectrode array

The purpose of this project was to investigate cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analytical techniques for enantioselective sensing at both a macroelectrode and a microelectrode array. The scale of the electrochemical cell was reduced from macro to micro dimens...

Full description

Bibliographic Details
Main Author: Delcourt-Lancon, Alice
Published: Durham University 2011
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.551411
id ndltd-bl.uk-oai-ethos.bl.uk-551411
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5514112015-03-20T04:51:32ZElectrochemical analysis supported by macro and microelectrode arrayDelcourt-Lancon, Alice2011The purpose of this project was to investigate cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analytical techniques for enantioselective sensing at both a macroelectrode and a microelectrode array. The scale of the electrochemical cell was reduced from macro to micro dimensions to improve both the electroanalytical detection and the efficient use of chemicals. A microdevice was fabricated using photolithography and plasma bonding and consisting of a microelectrode array (MEA) of 306 microelectrodes, each with a diameter of 45 µm supported by a polydimethylsiloxane (PDMS) slab engraved with microfluidic channels. The electroanalytical performances of the microdevice were characterised using cyclic voltammetry and it was established that the metallisation process influenced the surface roughness of the electrode, and also affected the final response of the array. The microdevice was used for flow injection analysis using chronoamperometry and provided the capability to detect small changes of analyte concentration. The selective electro-oxidation of phenylethanol catalysed by TEMPO and (-)-sparteine at a macroelectrode and MEA was investigated. The CV analysis showed a reproducible selective oxidation in favour of the (-)-phenylethanol enantiomer. The performances of the electrodes were enhanced to improve their enantioselective capability, and to extend their application to biosensors by functionalising their surface with Self-Assembled Monolayers (SAM). The electrodes were modified with glutathione and cysteine chiral molecules to investigate their ability to recognise the proline enantiomers using EIS analysis. The electron transfer rate of the ferricyanide analyte at the cysteine monolayer was less in the presence of D proline than it was in the presence of L-proline, indicating the selective penetration of the enantiomer through the monolayer. The properties of the macroelectrode and MEA were extended to biological applications by modifying their surfaces with thiolated single stranded DNA.541.37Durham Universityhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.551411http://etheses.dur.ac.uk/3570/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 541.37
spellingShingle 541.37
Delcourt-Lancon, Alice
Electrochemical analysis supported by macro and microelectrode array
description The purpose of this project was to investigate cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analytical techniques for enantioselective sensing at both a macroelectrode and a microelectrode array. The scale of the electrochemical cell was reduced from macro to micro dimensions to improve both the electroanalytical detection and the efficient use of chemicals. A microdevice was fabricated using photolithography and plasma bonding and consisting of a microelectrode array (MEA) of 306 microelectrodes, each with a diameter of 45 µm supported by a polydimethylsiloxane (PDMS) slab engraved with microfluidic channels. The electroanalytical performances of the microdevice were characterised using cyclic voltammetry and it was established that the metallisation process influenced the surface roughness of the electrode, and also affected the final response of the array. The microdevice was used for flow injection analysis using chronoamperometry and provided the capability to detect small changes of analyte concentration. The selective electro-oxidation of phenylethanol catalysed by TEMPO and (-)-sparteine at a macroelectrode and MEA was investigated. The CV analysis showed a reproducible selective oxidation in favour of the (-)-phenylethanol enantiomer. The performances of the electrodes were enhanced to improve their enantioselective capability, and to extend their application to biosensors by functionalising their surface with Self-Assembled Monolayers (SAM). The electrodes were modified with glutathione and cysteine chiral molecules to investigate their ability to recognise the proline enantiomers using EIS analysis. The electron transfer rate of the ferricyanide analyte at the cysteine monolayer was less in the presence of D proline than it was in the presence of L-proline, indicating the selective penetration of the enantiomer through the monolayer. The properties of the macroelectrode and MEA were extended to biological applications by modifying their surfaces with thiolated single stranded DNA.
author Delcourt-Lancon, Alice
author_facet Delcourt-Lancon, Alice
author_sort Delcourt-Lancon, Alice
title Electrochemical analysis supported by macro and microelectrode array
title_short Electrochemical analysis supported by macro and microelectrode array
title_full Electrochemical analysis supported by macro and microelectrode array
title_fullStr Electrochemical analysis supported by macro and microelectrode array
title_full_unstemmed Electrochemical analysis supported by macro and microelectrode array
title_sort electrochemical analysis supported by macro and microelectrode array
publisher Durham University
publishDate 2011
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.551411
work_keys_str_mv AT delcourtlanconalice electrochemicalanalysissupportedbymacroandmicroelectrodearray
_version_ 1716787353863847936