Performance of direct power controlled grid-connected voltage source converters

In this thesis the performance of direct power controlled grid-connected voltage source converters (VSCs) is investigated. Of particular interest is the stability of the controller with the third-order LCL filter employed as the grid filter, effect of grid impedance variations and grid voltage disto...

Full description

Bibliographic Details
Main Author: Mulolani, Francis
Published: University of Newcastle upon Tyne 2017
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.740508
id ndltd-bl.uk-oai-ethos.bl.uk-740508
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-7405082019-01-08T03:22:32ZPerformance of direct power controlled grid-connected voltage source convertersMulolani, Francis2017In this thesis the performance of direct power controlled grid-connected voltage source converters (VSCs) is investigated. Of particular interest is the stability of the controller with the third-order LCL filter employed as the grid filter, effect of grid impedance variations and grid voltage distortion, and current limitation during voltage dips. The control scheme implemented is virtual-flux direct power control with space vector modulation (VF-DPC-SVM). By mathematical modelling and stability analysis, it is found that the closed-loop power control system is stable for all values of proportional gain when the current sensors are on the inverter side of the LCL filter. The inverter current together with the estimated grid virtual-flux is used to estimate the active power and the reactive power. The difference between the estimated reactive power and the reactive power on the grid side is compensated for, using a new reactive power error compensation scheme based on the estimated capacitor current. The control system is found to be robust to changes in grid inductance, and remains stable for a range of grid inductance values, and controller proportional gain. It is demonstrated in simulation and experimentally that the total harmonic distortion (THD) of the current injected by the VSC is less than the limit of 5 %, set by standards, for all different values of grid inductance and proportional gain. This is true even in the presence of significant grid voltage distortion. To control the VSC during voltage dips without damaging the semiconductor devices, a new current limiting algorithm is proposed and implemented. The positive-sequence component of the virtual-flux is used for synchronization and power estimation to achieve balanced, undistorted currents during unsymmetrical voltage dips. Experimental results show that the current achieved during unsymmetrical voltage dips is balanced and has a THD of less than 3 %.University of Newcastle upon Tynehttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.740508http://hdl.handle.net/10443/3754Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
description In this thesis the performance of direct power controlled grid-connected voltage source converters (VSCs) is investigated. Of particular interest is the stability of the controller with the third-order LCL filter employed as the grid filter, effect of grid impedance variations and grid voltage distortion, and current limitation during voltage dips. The control scheme implemented is virtual-flux direct power control with space vector modulation (VF-DPC-SVM). By mathematical modelling and stability analysis, it is found that the closed-loop power control system is stable for all values of proportional gain when the current sensors are on the inverter side of the LCL filter. The inverter current together with the estimated grid virtual-flux is used to estimate the active power and the reactive power. The difference between the estimated reactive power and the reactive power on the grid side is compensated for, using a new reactive power error compensation scheme based on the estimated capacitor current. The control system is found to be robust to changes in grid inductance, and remains stable for a range of grid inductance values, and controller proportional gain. It is demonstrated in simulation and experimentally that the total harmonic distortion (THD) of the current injected by the VSC is less than the limit of 5 %, set by standards, for all different values of grid inductance and proportional gain. This is true even in the presence of significant grid voltage distortion. To control the VSC during voltage dips without damaging the semiconductor devices, a new current limiting algorithm is proposed and implemented. The positive-sequence component of the virtual-flux is used for synchronization and power estimation to achieve balanced, undistorted currents during unsymmetrical voltage dips. Experimental results show that the current achieved during unsymmetrical voltage dips is balanced and has a THD of less than 3 %.
author Mulolani, Francis
spellingShingle Mulolani, Francis
Performance of direct power controlled grid-connected voltage source converters
author_facet Mulolani, Francis
author_sort Mulolani, Francis
title Performance of direct power controlled grid-connected voltage source converters
title_short Performance of direct power controlled grid-connected voltage source converters
title_full Performance of direct power controlled grid-connected voltage source converters
title_fullStr Performance of direct power controlled grid-connected voltage source converters
title_full_unstemmed Performance of direct power controlled grid-connected voltage source converters
title_sort performance of direct power controlled grid-connected voltage source converters
publisher University of Newcastle upon Tyne
publishDate 2017
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.740508
work_keys_str_mv AT mulolanifrancis performanceofdirectpowercontrolledgridconnectedvoltagesourceconverters
_version_ 1718807077854380032