Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials

OBJECTIVES: To test and compare the effects of static and cyclic loading on fracture toughness (K1C) and microhardness of dental restorative CAD/CAM materials. MATERIAL AND METHODS: Five commercially available CAD/CAM restorative materials were included in this study: Lava™ Ultimate Restorative (3M...

Full description

Bibliographic Details
Main Author: Kensara, Alaa Ahmed
Language:en_US
Published: 2016
Subjects:
Online Access:https://hdl.handle.net/2144/18716
id ndltd-bu.edu-oai-open.bu.edu-2144-18716
record_format oai_dc
spelling ndltd-bu.edu-oai-open.bu.edu-2144-187162019-01-08T15:39:31Z Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials Kensara, Alaa Ahmed Dentistry CAD/CAM Cyclic loading Fatigue Fracture toughness Indentation Microhardness OBJECTIVES: To test and compare the effects of static and cyclic loading on fracture toughness (K1C) and microhardness of dental restorative CAD/CAM materials. MATERIAL AND METHODS: Five commercially available CAD/CAM restorative materials were included in this study: Lava™ Ultimate Restorative (3M ESPE), IPS Empress® CAD (Ivoclar Vivadent), Enamic® (VITA), IPS e.max® CAD (Ivoclar Vivadent), and CERASMART™ (GC Dental). Polished rectangular bars 4×2×14 mm (n=30) were prepared from mill blocks for each material. Single notch of 0.5-1 mm in depth was made on the center of one length edge. Ten specimens per group for each material were randomly selected for 1) static mode, 2) after 100k cyclic loads, and 3) after 200k cyclic loads. The survival bars after the fatigue test were then subjected to a three-point flexural test. K1C values were determined on ‘single-edge-pre-crack-beams’ (SEPB) method. In addition, random specimens after the flexural test were selected for Vickers microhardness test from each group. Additionally indentation fracture method (IF) was used to determine surface fracture toughness for e.max CAD and Empress CAD. All the results were analyzed via ANOVA with Tukey’s HSD test or least square regression model using JMP Pro 12.0. RESULTS: The mean fracture toughness (K1C) of the material tested in static mode (3.2 MPa.m1/2 for e.max CAD, 2 MPa.m1/2 for Lava Ult, 1.95 MPa.m1/2 for Empress CAD, 1.92 MPa.m1/2 for Enamic, and 1.65 MPa.m1/2 for Cerasmart). The 100k fatigue group (4.02 MPa.m1/2 for e.max CAD, 3.06 MPa.m1/2 for Cerasmart, 2.55 MPa.m1/2 for Lava Ult, 2.01 MPa.m1/2 for Enamic, 1.94 MPa.m1/2 for Empress CAD) The 200k fatigue group (3.14 MPa.m1/2 for Cerasmart, 2.83 MPa.m1/2 for Lava Ult, 2.68 MPa.m1/2 for e.max CAD, 2.01 MPa.m1/2 for Enamic, 1.72 MPa.m1/2 for Empress CAD). While there was a significant difference in the mean fracture toughness (K1C) and (VHN) after fatigue of material tested (p<0.05). CONCLUSION: The CAD/CAM materials tested exhibited a higher K1C values after cyclic loading, along with lower K1C compared to the static group. In addition, K1C values by IF method exhibit lower K1C values after fatigue that was not a good way to test the fracture toughness value. 2018-09-28T00:00:00Z 2016-10-26T15:34:41Z 2016 2016-09-28T16:08:54Z Thesis/Dissertation https://hdl.handle.net/2144/18716 en_US
collection NDLTD
language en_US
sources NDLTD
topic Dentistry
CAD/CAM
Cyclic loading
Fatigue
Fracture toughness
Indentation
Microhardness
spellingShingle Dentistry
CAD/CAM
Cyclic loading
Fatigue
Fracture toughness
Indentation
Microhardness
Kensara, Alaa Ahmed
Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
description OBJECTIVES: To test and compare the effects of static and cyclic loading on fracture toughness (K1C) and microhardness of dental restorative CAD/CAM materials. MATERIAL AND METHODS: Five commercially available CAD/CAM restorative materials were included in this study: Lava™ Ultimate Restorative (3M ESPE), IPS Empress® CAD (Ivoclar Vivadent), Enamic® (VITA), IPS e.max® CAD (Ivoclar Vivadent), and CERASMART™ (GC Dental). Polished rectangular bars 4×2×14 mm (n=30) were prepared from mill blocks for each material. Single notch of 0.5-1 mm in depth was made on the center of one length edge. Ten specimens per group for each material were randomly selected for 1) static mode, 2) after 100k cyclic loads, and 3) after 200k cyclic loads. The survival bars after the fatigue test were then subjected to a three-point flexural test. K1C values were determined on ‘single-edge-pre-crack-beams’ (SEPB) method. In addition, random specimens after the flexural test were selected for Vickers microhardness test from each group. Additionally indentation fracture method (IF) was used to determine surface fracture toughness for e.max CAD and Empress CAD. All the results were analyzed via ANOVA with Tukey’s HSD test or least square regression model using JMP Pro 12.0. RESULTS: The mean fracture toughness (K1C) of the material tested in static mode (3.2 MPa.m1/2 for e.max CAD, 2 MPa.m1/2 for Lava Ult, 1.95 MPa.m1/2 for Empress CAD, 1.92 MPa.m1/2 for Enamic, and 1.65 MPa.m1/2 for Cerasmart). The 100k fatigue group (4.02 MPa.m1/2 for e.max CAD, 3.06 MPa.m1/2 for Cerasmart, 2.55 MPa.m1/2 for Lava Ult, 2.01 MPa.m1/2 for Enamic, 1.94 MPa.m1/2 for Empress CAD) The 200k fatigue group (3.14 MPa.m1/2 for Cerasmart, 2.83 MPa.m1/2 for Lava Ult, 2.68 MPa.m1/2 for e.max CAD, 2.01 MPa.m1/2 for Enamic, 1.72 MPa.m1/2 for Empress CAD). While there was a significant difference in the mean fracture toughness (K1C) and (VHN) after fatigue of material tested (p<0.05). CONCLUSION: The CAD/CAM materials tested exhibited a higher K1C values after cyclic loading, along with lower K1C compared to the static group. In addition, K1C values by IF method exhibit lower K1C values after fatigue that was not a good way to test the fracture toughness value. === 2018-09-28T00:00:00Z
author Kensara, Alaa Ahmed
author_facet Kensara, Alaa Ahmed
author_sort Kensara, Alaa Ahmed
title Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
title_short Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
title_full Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
title_fullStr Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
title_full_unstemmed Static and cyclic loading effects on fracture toughness of contemporary CAD/CAM restorative materials
title_sort static and cyclic loading effects on fracture toughness of contemporary cad/cam restorative materials
publishDate 2016
url https://hdl.handle.net/2144/18716
work_keys_str_mv AT kensaraalaaahmed staticandcyclicloadingeffectsonfracturetoughnessofcontemporarycadcamrestorativematerials
_version_ 1718811861246279680