The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings

Submitted in partial compliance with the requirements for the Master’s Degree in Technology: Chiropractic, Durban University of Technology, South Africa, 2013. === Background: Lateral ankle sprains and the sequelae of Chronic Ankle Instability Syndrome (CAIS) are common, reaching a peak prevalence o...

Full description

Bibliographic Details
Main Author: Botha, André
Other Authors: Korporaal, Charmaine Maria
Format: Others
Language:en
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10321/1209
id ndltd-netd.ac.za-oai-union.ndltd.org-dut-oai-localhost-10321-1209
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-dut-oai-localhost-10321-12092016-04-21T04:10:54Z The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings Botha, André Korporaal, Charmaine Maria White, Horace Lindsay Chiropractic Ankle--Wounds and injuries--Chiropractic treatment Manipulation (Therapeutics) Submitted in partial compliance with the requirements for the Master’s Degree in Technology: Chiropractic, Durban University of Technology, South Africa, 2013. Background: Lateral ankle sprains and the sequelae of Chronic Ankle Instability Syndrome (CAIS) are common, reaching a peak prevalence of 85%. Manual joint manipulation is an intervention utilised for CAIS. Manipulations are applied either manually or via a mechanical device. The Activator Adjustment Instrument (AAI) is commonly applied to extremities; however, a paucity of research exists, in respect of extremity conditions. Thus this study compared an AAI manipulation with a manual long-axis distraction manipulation (diversified technique) in the treatment of CAIS. Method: This ethics approved, quantitative, randomised controlled clinical trial, of 40 participants allocated between two groups. After receipt of informed consent participants were evaluated against the inclusion criteria and baseline measures were taken. One treatment of either manual or activator manipulation was followed by a measurements-only consultation within 48 hours. A p-value <0.05 was considered statistically significant. Intra- and inter-group analyses were done utilising repeated measures ANOVA tests. Results: Both groups showed a statistically significant improvement on all outcome measures over time, but neither group showed a significant improvement over the other. A trend in the inter-group comparisons reflected parallel improvements in the Algometer, Berg Balance Scale and the dorsiflexion range of motion (objective measures) and non-parallel improvements in the Numerical Pain Rating Scale and Foot and Ankle Disability Index. Conclusion: The results suggested a trend towards subjective improvement in the AAI group, which may have been influenced by the novelty of the AAI. Further research with larger sample sizes and more homogenous participant groups are needed to verify this outcome. 2015-02-10T05:43:52Z 2015-02-10T05:43:52Z 2015-02-10 Thesis 482643 http://hdl.handle.net/10321/1209 en 170 p
collection NDLTD
language en
format Others
sources NDLTD
topic Chiropractic
Ankle--Wounds and injuries--Chiropractic treatment
Manipulation (Therapeutics)
spellingShingle Chiropractic
Ankle--Wounds and injuries--Chiropractic treatment
Manipulation (Therapeutics)
Botha, André
The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
description Submitted in partial compliance with the requirements for the Master’s Degree in Technology: Chiropractic, Durban University of Technology, South Africa, 2013. === Background: Lateral ankle sprains and the sequelae of Chronic Ankle Instability Syndrome (CAIS) are common, reaching a peak prevalence of 85%. Manual joint manipulation is an intervention utilised for CAIS. Manipulations are applied either manually or via a mechanical device. The Activator Adjustment Instrument (AAI) is commonly applied to extremities; however, a paucity of research exists, in respect of extremity conditions. Thus this study compared an AAI manipulation with a manual long-axis distraction manipulation (diversified technique) in the treatment of CAIS. Method: This ethics approved, quantitative, randomised controlled clinical trial, of 40 participants allocated between two groups. After receipt of informed consent participants were evaluated against the inclusion criteria and baseline measures were taken. One treatment of either manual or activator manipulation was followed by a measurements-only consultation within 48 hours. A p-value <0.05 was considered statistically significant. Intra- and inter-group analyses were done utilising repeated measures ANOVA tests. Results: Both groups showed a statistically significant improvement on all outcome measures over time, but neither group showed a significant improvement over the other. A trend in the inter-group comparisons reflected parallel improvements in the Algometer, Berg Balance Scale and the dorsiflexion range of motion (objective measures) and non-parallel improvements in the Numerical Pain Rating Scale and Foot and Ankle Disability Index. Conclusion: The results suggested a trend towards subjective improvement in the AAI group, which may have been influenced by the novelty of the AAI. Further research with larger sample sizes and more homogenous participant groups are needed to verify this outcome.
author2 Korporaal, Charmaine Maria
author_facet Korporaal, Charmaine Maria
Botha, André
author Botha, André
author_sort Botha, André
title The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
title_short The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
title_full The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
title_fullStr The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
title_full_unstemmed The relative effectiveness of the Activator Adjustment Instrument versus diversified manipulation technique in Chronic Ankle Instability Syndrome (CAIS) in terms of objective and subjective findings
title_sort relative effectiveness of the activator adjustment instrument versus diversified manipulation technique in chronic ankle instability syndrome (cais) in terms of objective and subjective findings
publishDate 2015
url http://hdl.handle.net/10321/1209
work_keys_str_mv AT bothaandre therelativeeffectivenessoftheactivatoradjustmentinstrumentversusdiversifiedmanipulationtechniqueinchronicankleinstabilitysyndromecaisintermsofobjectiveandsubjectivefindings
AT bothaandre relativeeffectivenessoftheactivatoradjustmentinstrumentversusdiversifiedmanipulationtechniqueinchronicankleinstabilitysyndromecaisintermsofobjectiveandsubjectivefindings
_version_ 1718229438874779648