Effect of conductor size on the total cost of electricity distribution feeders in South African electrification
Includes bibliographical references (p. 191-201). === There is an optimum conductor size that minimises the lifetime cost of domestic electrification networks. The lifetime cost consists of the initial capital cost and ongoing running cost. Technical load losses are an important running cost and con...
Main Author: | |
---|---|
Other Authors: | |
Format: | Doctoral Thesis |
Language: | English |
Published: |
University of Cape Town
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/11427/5257 |
id |
ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-5257 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-52572020-12-10T05:11:11Z Effect of conductor size on the total cost of electricity distribution feeders in South African electrification Carter-Brown, Clinton Geoffrey Gaunt, C Trevor Electrical Engineering Includes bibliographical references (p. 191-201). There is an optimum conductor size that minimises the lifetime cost of domestic electrification networks. The lifetime cost consists of the initial capital cost and ongoing running cost. Technical load losses are an important running cost and consideration for conductor size optimisation. Traditional conductor size optimisation methods base technical load loss costs on upstream generation and network costs. These loss costing methods assume that consumers behave as constant power loads. The impact of conductor voltage drops on changes in consumer energy consumption and demand and hence changes in utility bulk purchase cost and sales revenue are ignored. Traditional load loss calculation methods do not adequately describe the stochastic nature of individual consumer loads. In low-voltage domestic networks traditional methods may account for less than 25% of the actual lifetime running cost due to load losses and conductor voltage drop. It is shown that the results of traditional conductor size optimisation methods are severely compromised. 2014-07-31T11:00:29Z 2014-07-31T11:00:29Z 2006 Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/5257 eng application/pdf University of Cape Town Faculty of Engineering and the Built Environment Department of Electrical Engineering |
collection |
NDLTD |
language |
English |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
Electrical Engineering |
spellingShingle |
Electrical Engineering Carter-Brown, Clinton Geoffrey Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
description |
Includes bibliographical references (p. 191-201). === There is an optimum conductor size that minimises the lifetime cost of domestic electrification networks. The lifetime cost consists of the initial capital cost and ongoing running cost. Technical load losses are an important running cost and consideration for conductor size optimisation. Traditional conductor size optimisation methods base technical load loss costs on upstream generation and network costs. These loss costing methods assume that consumers behave as constant power loads. The impact of conductor voltage drops on changes in consumer energy consumption and demand and hence changes in utility bulk purchase cost and sales revenue are ignored. Traditional load loss calculation methods do not adequately describe the stochastic nature of individual consumer loads. In low-voltage domestic networks traditional methods may account for less than 25% of the actual lifetime running cost due to load losses and conductor voltage drop. It is shown that the results of traditional conductor size optimisation methods are severely compromised. |
author2 |
Gaunt, C Trevor |
author_facet |
Gaunt, C Trevor Carter-Brown, Clinton Geoffrey |
author |
Carter-Brown, Clinton Geoffrey |
author_sort |
Carter-Brown, Clinton Geoffrey |
title |
Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
title_short |
Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
title_full |
Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
title_fullStr |
Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
title_full_unstemmed |
Effect of conductor size on the total cost of electricity distribution feeders in South African electrification |
title_sort |
effect of conductor size on the total cost of electricity distribution feeders in south african electrification |
publisher |
University of Cape Town |
publishDate |
2014 |
url |
http://hdl.handle.net/11427/5257 |
work_keys_str_mv |
AT carterbrownclintongeoffrey effectofconductorsizeonthetotalcostofelectricitydistributionfeedersinsouthafricanelectrification |
_version_ |
1719369877292056576 |