Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid

A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, in ful lment of the requirements for the degree of Master of Science in Engineering. Johannesburg, 2016 === This research investigates the power sharing between distributed energy re...

Full description

Bibliographic Details
Main Author: Wu, Meng-Chun Merelda
Format: Others
Language:en
Published: 2016
Subjects:
Online Access:Wu, Meng-Chun Merelda (2016) Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid, University of Witwatersrand, Johannesburg, <http://wiredspace.wits.ac.za/handle/10539/21052>
http://hdl.handle.net/10539/21052
id ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-21052
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-210522019-05-11T03:42:07Z Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid Wu, Meng-Chun Merelda Distributed generation of electric power Electric power distribution Renewable energy sources Smart power grids A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, in ful lment of the requirements for the degree of Master of Science in Engineering. Johannesburg, 2016 This research investigates the power sharing between distributed energy resources with voltage and frequency droop control. A case study based on voltage sources in an islanded microgrid is set up in the laboratory, referred to as: The Example Microgrid. The Example Microgrid consists of two synchronous generators, active and reactive power loads. A simulation model is constructed based on the laboratory set-up, where componentwise and system-wise testing are completed. The simulation results are validated with the experimental set-up, and it is concluded that the model accurately represents the physical system under steady-state conditions. Further simulation studies on conventional droop controllers are conducted based on the Example Microgrid model. The results indicate that the use of conventional droop control is inappropriate for small, low-voltage islanded microgrids. As a possible application of this work, three variations of adapted droop controllers are simulated and their performance evaluated. It is found that with the adapted droop controllers, the power sharing error can be minimised M T 2016 2016-09-16T13:19:29Z 2016-09-16T13:19:29Z 2016 Thesis Wu, Meng-Chun Merelda (2016) Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid, University of Witwatersrand, Johannesburg, <http://wiredspace.wits.ac.za/handle/10539/21052> http://hdl.handle.net/10539/21052 en Online resource (146 leaves) application/pdf application/pdf
collection NDLTD
language en
format Others
sources NDLTD
topic Distributed generation of electric power
Electric power distribution
Renewable energy sources
Smart power grids
spellingShingle Distributed generation of electric power
Electric power distribution
Renewable energy sources
Smart power grids
Wu, Meng-Chun Merelda
Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
description A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, in ful lment of the requirements for the degree of Master of Science in Engineering. Johannesburg, 2016 === This research investigates the power sharing between distributed energy resources with voltage and frequency droop control. A case study based on voltage sources in an islanded microgrid is set up in the laboratory, referred to as: The Example Microgrid. The Example Microgrid consists of two synchronous generators, active and reactive power loads. A simulation model is constructed based on the laboratory set-up, where componentwise and system-wise testing are completed. The simulation results are validated with the experimental set-up, and it is concluded that the model accurately represents the physical system under steady-state conditions. Further simulation studies on conventional droop controllers are conducted based on the Example Microgrid model. The results indicate that the use of conventional droop control is inappropriate for small, low-voltage islanded microgrids. As a possible application of this work, three variations of adapted droop controllers are simulated and their performance evaluated. It is found that with the adapted droop controllers, the power sharing error can be minimised === M T 2016
author Wu, Meng-Chun Merelda
author_facet Wu, Meng-Chun Merelda
author_sort Wu, Meng-Chun Merelda
title Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
title_short Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
title_full Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
title_fullStr Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
title_full_unstemmed Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
title_sort investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid
publishDate 2016
url Wu, Meng-Chun Merelda (2016) Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid, University of Witwatersrand, Johannesburg, <http://wiredspace.wits.ac.za/handle/10539/21052>
http://hdl.handle.net/10539/21052
work_keys_str_mv AT wumengchunmerelda investigationintothesteadystateloadsharingofweaksourcesinalowvoltagethreephaseislandedmicrogrid
_version_ 1719085083250393088