Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy

It has been designed tITP - CZE method with a reversed electro-osmotic flow for the analysis of seven organic acids of natural origin. It was monitorated the effect of boric buffer concentration, pH effect, the addition of organic solvent, the addition of cyclodextrin, concentration of NaCl as a sta...

Full description

Bibliographic Details
Main Author: Černá, Veronika
Other Authors: Polášek, Miroslav
Format: Dissertation
Language:Czech
Published: 2009
Online Access:http://www.nusl.cz/ntk/nusl-279539
id ndltd-nusl.cz-oai-invenio.nusl.cz-279539
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2795392017-06-27T04:40:40Z Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy Analysis of natural compounds by capillary isotachophoresis and capillary zone electrophoresis. Polášek, Miroslav Černá, Veronika Pospíšilová, Marie It has been designed tITP - CZE method with a reversed electro-osmotic flow for the analysis of seven organic acids of natural origin. It was monitorated the effect of boric buffer concentration, pH effect, the addition of organic solvent, the addition of cyclodextrin, concentration of NaCl as a stacker, and injection time. Measurements were made in voltage - 30 kV in capillary with inner diameter 50 μm and effective length 68 cm. Optimum separation conditions were found at a concentration of 125mM boric buffer, pH 8,2, the addition of 0,001% hexadimethrinbromid and addition of 10mM and 2,6-di-O- methylcyklodextrin. The stacker was used at a concentration of 200mM NaCl and injection time was 90 s. Intracapillary thermal gradient from 20o C to 24řC during electrophoresis has yielded improved resolution for the analytes. 2009 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-279539 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description It has been designed tITP - CZE method with a reversed electro-osmotic flow for the analysis of seven organic acids of natural origin. It was monitorated the effect of boric buffer concentration, pH effect, the addition of organic solvent, the addition of cyclodextrin, concentration of NaCl as a stacker, and injection time. Measurements were made in voltage - 30 kV in capillary with inner diameter 50 μm and effective length 68 cm. Optimum separation conditions were found at a concentration of 125mM boric buffer, pH 8,2, the addition of 0,001% hexadimethrinbromid and addition of 10mM and 2,6-di-O- methylcyklodextrin. The stacker was used at a concentration of 200mM NaCl and injection time was 90 s. Intracapillary thermal gradient from 20o C to 24řC during electrophoresis has yielded improved resolution for the analytes.
author2 Polášek, Miroslav
author_facet Polášek, Miroslav
Černá, Veronika
author Černá, Veronika
spellingShingle Černá, Veronika
Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
author_sort Černá, Veronika
title Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
title_short Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
title_full Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
title_fullStr Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
title_full_unstemmed Analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
title_sort analýza látek přírodního původu metodou kapilární izotachoforézy a kapilární zónové elektroforézy
publishDate 2009
url http://www.nusl.cz/ntk/nusl-279539
work_keys_str_mv AT cernaveronika analyzalatekprirodnihopuvodumetodoukapilarniizotachoforezyakapilarnizonoveelektroforezy
AT cernaveronika analysisofnaturalcompoundsbycapillaryisotachophoresisandcapillaryzoneelectrophoresis
_version_ 1718468723020398592