Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů

Every radiation counting system exhibits a characteristic pulse resolving time (dead time) that is related to the time required to individual detected events. In case that a second pulse occures before the first has disappeared the two pulses will form a single distored pulse. Because of dead time l...

Full description

Bibliographic Details
Main Author: Chromá, Ladislava
Other Authors: Zimák, Jaroslav
Format: Dissertation
Language:Czech
Published: 2010
Online Access:http://www.nusl.cz/ntk/nusl-282572
id ndltd-nusl.cz-oai-invenio.nusl.cz-282572
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2825722017-06-27T04:40:58Z Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů Effect of energy distribution spectrum of radionuclides on pulse resolving time of scintilation spectrometers Zimák, Jaroslav Chromá, Ladislava Nováková, Olga Every radiation counting system exhibits a characteristic pulse resolving time (dead time) that is related to the time required to individual detected events. In case that a second pulse occures before the first has disappeared the two pulses will form a single distored pulse. Because of dead time losses, the measured counting rate (cps) is less than the true (teoretical) counting rate. Pulse resolving time can considerably change the relationship in case of measuring small and high activities. According to experimental results in my work dead time losses are dependant on the scintillators type, time constant of pulse amplifier and energy of radionuklides. There are given counting rate limits for three radionuklides - 99mTc, 51Cr and 131I and two scintillation spectrometers - JKA 300 and JKA1102. 2010 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-282572 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description Every radiation counting system exhibits a characteristic pulse resolving time (dead time) that is related to the time required to individual detected events. In case that a second pulse occures before the first has disappeared the two pulses will form a single distored pulse. Because of dead time losses, the measured counting rate (cps) is less than the true (teoretical) counting rate. Pulse resolving time can considerably change the relationship in case of measuring small and high activities. According to experimental results in my work dead time losses are dependant on the scintillators type, time constant of pulse amplifier and energy of radionuklides. There are given counting rate limits for three radionuklides - 99mTc, 51Cr and 131I and two scintillation spectrometers - JKA 300 and JKA1102.
author2 Zimák, Jaroslav
author_facet Zimák, Jaroslav
Chromá, Ladislava
author Chromá, Ladislava
spellingShingle Chromá, Ladislava
Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
author_sort Chromá, Ladislava
title Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
title_short Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
title_full Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
title_fullStr Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
title_full_unstemmed Vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
title_sort vliv energetického rozložení spektra radionuklidů na časovou rozlišovací schopnost scintilačních spektrometrů
publishDate 2010
url http://www.nusl.cz/ntk/nusl-282572
work_keys_str_mv AT chromaladislava vlivenergetickehorozlozenispektraradionuklidunacasovourozlisovacischopnostscintilacnichspektrometru
AT chromaladislava effectofenergydistributionspectrumofradionuclidesonpulseresolvingtimeofscintilationspectrometers
_version_ 1718469159424098304