Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice

This diploma thesis deals with development and optimization of conditions of HPLC method for a suitable pre-concentration and determination of two pesticides - fenoxycarb and permethrin in surface waters. The on-line SPE HPLC with column switching system was used for method development and determina...

Full description

Bibliographic Details
Main Author: Naibrtová, Linda
Other Authors: Šatínský, Dalibor
Format: Dissertation
Language:Czech
Published: 2014
Online Access:http://www.nusl.cz/ntk/nusl-333062
id ndltd-nusl.cz-oai-invenio.nusl.cz-333062
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-3330622017-06-28T04:19:05Z Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice Column switching technique in HPLC for preconcentration and determination of insecticides in water matrix Naibrtová, Linda Šatínský, Dalibor Chocholouš, Petr This diploma thesis deals with development and optimization of conditions of HPLC method for a suitable pre-concentration and determination of two pesticides - fenoxycarb and permethrin in surface waters. The on-line SPE HPLC with column switching system was used for method development and determination. To validate the optimal conditions there was chosen analytical column Supelco Ascentis Express Phenyl - Hexyl (100 x 4.6 mm), particle size of 2.7 microns. Detection was carried out at wavelength 225 nm and column temperature was set on 45 řC using gradient elution with a mobile phase of acetonitrile - water at a flow rate of 1,0 ml/min. Prior to analysis, the sample was pre-concentrated using an extraction precolumn Ascentis Express C-18 (5 x 4.6 mm), particle size of 2.7 micron with washing mobile phase of 30% acetonitrile in water at a flow rate of 0.5 ml/min. The injected sample volume was optimized to 1500 μl of water sample. An original method, which allows the determination of two selected pesticides in real matrix surface waters without difficult sample pre-treatment was developed. 2014 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-333062 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description This diploma thesis deals with development and optimization of conditions of HPLC method for a suitable pre-concentration and determination of two pesticides - fenoxycarb and permethrin in surface waters. The on-line SPE HPLC with column switching system was used for method development and determination. To validate the optimal conditions there was chosen analytical column Supelco Ascentis Express Phenyl - Hexyl (100 x 4.6 mm), particle size of 2.7 microns. Detection was carried out at wavelength 225 nm and column temperature was set on 45 řC using gradient elution with a mobile phase of acetonitrile - water at a flow rate of 1,0 ml/min. Prior to analysis, the sample was pre-concentrated using an extraction precolumn Ascentis Express C-18 (5 x 4.6 mm), particle size of 2.7 micron with washing mobile phase of 30% acetonitrile in water at a flow rate of 0.5 ml/min. The injected sample volume was optimized to 1500 μl of water sample. An original method, which allows the determination of two selected pesticides in real matrix surface waters without difficult sample pre-treatment was developed.
author2 Šatínský, Dalibor
author_facet Šatínský, Dalibor
Naibrtová, Linda
author Naibrtová, Linda
spellingShingle Naibrtová, Linda
Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
author_sort Naibrtová, Linda
title Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
title_short Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
title_full Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
title_fullStr Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
title_full_unstemmed Využití systému přepínání kolon v HPLC pro zakoncentrování a stanovení insekticidů z vodné matrice
title_sort využití systému přepínání kolon v hplc pro zakoncentrování a stanovení insekticidů z vodné matrice
publishDate 2014
url http://www.nusl.cz/ntk/nusl-333062
work_keys_str_mv AT naibrtovalinda vyuzitisystemuprepinanikolonvhplcprozakoncentrovaniastanoveniinsekticiduzvodnematrice
AT naibrtovalinda columnswitchingtechniqueinhplcforpreconcentrationanddeterminationofinsecticidesinwatermatrix
_version_ 1718475789412859904