Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters

In previous studies the slotted orifice plate has demonstrated superior performance characteristics to those of the standard orifice plate. In this study, these comparisons are investigated further. The response characteristics of the slotted orifice plate to the standard orifice plate and V-Cone f...

Full description

Bibliographic Details
Main Author: Sparks, Sara A.
Other Authors: Morrison, Gerald
Format: Others
Language:en_US
Published: Texas A&M University 2004
Subjects:
Online Access:http://hdl.handle.net/1969.1/1088
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-1088
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-10882013-01-08T10:37:27ZTwo phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice metersSparks, Sara A.slotted orificetwo phase mixingstandard orificeIn previous studies the slotted orifice plate has demonstrated superior performance characteristics to those of the standard orifice plate. In this study, these comparisons are investigated further. The response characteristics of the slotted orifice plate to the standard orifice plate and V-Cone for two-phase flows of water and air at various qualities, flow rates, and pressures are shown visually. The effect of oil as it flows through a slotted orifice plate and standard orifice plate are visually documented. The effect of manufacturing accuracy on the slotted orifice plates is investigated as to the effect on the coefficient of discharge, percent change in pressure, and Reynolds number. The slotted orifice plate mixes two-phase flow better than the standard orifice plate and V-Cone. There is a manufacturing effect on the slotted orifice plates; the larger the area of the slots, the larger the discharge coefficient.Texas A&M UniversityMorrison, Gerald2004-11-15T19:45:58Z2004-11-15T19:45:58Z2004-082004-11-15T19:45:58ZBookThesisElectronic Thesistext931846 bytes97987 byteselectronicapplication/pdftext/plainborn digitalhttp://hdl.handle.net/1969.1/1088en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic slotted orifice
two phase mixing
standard orifice
spellingShingle slotted orifice
two phase mixing
standard orifice
Sparks, Sara A.
Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
description In previous studies the slotted orifice plate has demonstrated superior performance characteristics to those of the standard orifice plate. In this study, these comparisons are investigated further. The response characteristics of the slotted orifice plate to the standard orifice plate and V-Cone for two-phase flows of water and air at various qualities, flow rates, and pressures are shown visually. The effect of oil as it flows through a slotted orifice plate and standard orifice plate are visually documented. The effect of manufacturing accuracy on the slotted orifice plates is investigated as to the effect on the coefficient of discharge, percent change in pressure, and Reynolds number. The slotted orifice plate mixes two-phase flow better than the standard orifice plate and V-Cone. There is a manufacturing effect on the slotted orifice plates; the larger the area of the slots, the larger the discharge coefficient.
author2 Morrison, Gerald
author_facet Morrison, Gerald
Sparks, Sara A.
author Sparks, Sara A.
author_sort Sparks, Sara A.
title Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
title_short Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
title_full Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
title_fullStr Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
title_full_unstemmed Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
title_sort two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
publisher Texas A&M University
publishDate 2004
url http://hdl.handle.net/1969.1/1088
work_keys_str_mv AT sparkssaraa twophasemixingcomparisonoilcontaminationcomparisonandmanufacturingaccuracyeffectoncalibrationofslottedorificemeters
_version_ 1716502667595874304