Prompt gamma imaging with a slit camera for real time range control in particle therapy

In a growing number of cutting edge centres around the world, radiotherapy treatments delivered by beams of protons and carbon ions offer the opportunity to target tumours with unprecedented conformality. But a sharper dose distribution increases the need for efficient quality control. Treatments ar...

Full description

Bibliographic Details
Main Author: Smeets, Julien
Other Authors: Dehaes, Jean-Claude
Format: Doctoral Thesis
Language:fr
Published: Universite Libre de Bruxelles 2012
Subjects:
Online Access:http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/209624
id ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-209624
record_format oai_dc
spelling ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-2096242018-04-11T17:33:59Z info:eu-repo/semantics/doctoralThesis info:ulb-repo/semantics/doctoralThesis info:ulb-repo/semantics/openurl/vlink-dissertation Prompt gamma imaging with a slit camera for real time range control in particle therapy Smeets, Julien Dehaes, Jean-Claude Dubus, Alain Sparenberg, Jean-Marc Dauvergne, Denis Tavernier, Stefaan Sterpin, Edmond Stichelbaut, Frédéric T. Kockaert, Pascal Universite Libre de Bruxelles Université libre de Bruxelles, Ecole polytechnique de Bruxelles – Physicien, Bruxelles 2012-10-10 fr In a growing number of cutting edge centres around the world, radiotherapy treatments delivered by beams of protons and carbon ions offer the opportunity to target tumours with unprecedented conformality. But a sharper dose distribution increases the need for efficient quality control. Treatments are still affected by uncertainties on the penetration depth of the beam within the patient, requiring medical physicists to add safety margins. To reduce these margins and deliver safer treatments, different projects investigate real time range control by imaging prompt gammas emitted along the proton or carbon ion tracks in the patient.<p><p>This thesis reports on the feasibility, development and test of a new type of prompt gamma camera for proton therapy. This concept uses a knife-edge slit collimator to obtain a 1-dimensional projection of the beam path on a gamma camera. It was optimized, using the Monte Carlo code MCNPX version 2.5.0, to select high energy photons correlated with the beam range and detect them with both high counting statistics and sufficient spatial resolution for use in clinical routine. To validate the Monte Carlo model, spectrometry measurements of secondary particles emitted by a PMMA target during proton irradiation at 160 MeV were realised. An excellent agreement with the simulations was observed when using subtraction methods to isolate the gammas in direct incidence. A first prototype slit camera using the HiCam gamma detector was consequently prepared and tested successfully at 100 and 160 MeV beam energies. If we neglect electronic dead times and rejection of detected events, the current solution with its collimator at 15 cm from beam axis can achieve a 1-2 mm standard deviation on range estimation in a homogeneous PMMA target for numbers of protons that correspond to doses in water at Bragg peak as low as 15 cGy at 100 MeV and 25 cGy at 160 MeV assuming pencil beams with a Gaussian profile of 5 mm sigma at target entrance.<p><p>This thesis also investigates the applicability of the slit camera for carbon ion therapy. On the basis of Monte Carlo simulations with the code MCNPX version 2.7.E, this type of camera appears not to be able to identify the beam range with the required sensitivity. The feasibility of prompt gamma imaging itself seems questionable at high beam energies given the weak correlation of secondaries leaving the patient.<p><p>This work consequently concludes to the relevance of the slit camera approach for real time range monitoring in proton therapy, but not in carbon ion therapy. Physique Sciences de l'ingénieur Radiotherapy Proton beams -- Therapeutic use Radiothérapie Faisceaux de protons -- Emploi en thérapeutique Range control Monte Carlo Slit camera Prompt gamma Proton therapy 1 v. (xii, 212 p.) Doctorat en Sciences de l'ingénieur info:eu-repo/semantics/nonPublished local/bictel.ulb.ac.be:ULBetd-10182012-123741 local/ulbcat.ulb.ac.be:968068 http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/209624 No full-text files
collection NDLTD
language fr
format Doctoral Thesis
sources NDLTD
topic Physique
Sciences de l'ingénieur
Radiotherapy
Proton beams -- Therapeutic use
Radiothérapie
Faisceaux de protons -- Emploi en thérapeutique
Range control
Monte Carlo
Slit camera
Prompt gamma
Proton therapy
spellingShingle Physique
Sciences de l'ingénieur
Radiotherapy
Proton beams -- Therapeutic use
Radiothérapie
Faisceaux de protons -- Emploi en thérapeutique
Range control
Monte Carlo
Slit camera
Prompt gamma
Proton therapy
Smeets, Julien
Prompt gamma imaging with a slit camera for real time range control in particle therapy
description In a growing number of cutting edge centres around the world, radiotherapy treatments delivered by beams of protons and carbon ions offer the opportunity to target tumours with unprecedented conformality. But a sharper dose distribution increases the need for efficient quality control. Treatments are still affected by uncertainties on the penetration depth of the beam within the patient, requiring medical physicists to add safety margins. To reduce these margins and deliver safer treatments, different projects investigate real time range control by imaging prompt gammas emitted along the proton or carbon ion tracks in the patient.<p><p>This thesis reports on the feasibility, development and test of a new type of prompt gamma camera for proton therapy. This concept uses a knife-edge slit collimator to obtain a 1-dimensional projection of the beam path on a gamma camera. It was optimized, using the Monte Carlo code MCNPX version 2.5.0, to select high energy photons correlated with the beam range and detect them with both high counting statistics and sufficient spatial resolution for use in clinical routine. To validate the Monte Carlo model, spectrometry measurements of secondary particles emitted by a PMMA target during proton irradiation at 160 MeV were realised. An excellent agreement with the simulations was observed when using subtraction methods to isolate the gammas in direct incidence. A first prototype slit camera using the HiCam gamma detector was consequently prepared and tested successfully at 100 and 160 MeV beam energies. If we neglect electronic dead times and rejection of detected events, the current solution with its collimator at 15 cm from beam axis can achieve a 1-2 mm standard deviation on range estimation in a homogeneous PMMA target for numbers of protons that correspond to doses in water at Bragg peak as low as 15 cGy at 100 MeV and 25 cGy at 160 MeV assuming pencil beams with a Gaussian profile of 5 mm sigma at target entrance.<p><p>This thesis also investigates the applicability of the slit camera for carbon ion therapy. On the basis of Monte Carlo simulations with the code MCNPX version 2.7.E, this type of camera appears not to be able to identify the beam range with the required sensitivity. The feasibility of prompt gamma imaging itself seems questionable at high beam energies given the weak correlation of secondaries leaving the patient.<p><p>This work consequently concludes to the relevance of the slit camera approach for real time range monitoring in proton therapy, but not in carbon ion therapy. === Doctorat en Sciences de l'ingénieur === info:eu-repo/semantics/nonPublished
author2 Dehaes, Jean-Claude
author_facet Dehaes, Jean-Claude
Smeets, Julien
author Smeets, Julien
author_sort Smeets, Julien
title Prompt gamma imaging with a slit camera for real time range control in particle therapy
title_short Prompt gamma imaging with a slit camera for real time range control in particle therapy
title_full Prompt gamma imaging with a slit camera for real time range control in particle therapy
title_fullStr Prompt gamma imaging with a slit camera for real time range control in particle therapy
title_full_unstemmed Prompt gamma imaging with a slit camera for real time range control in particle therapy
title_sort prompt gamma imaging with a slit camera for real time range control in particle therapy
publisher Universite Libre de Bruxelles
publishDate 2012
url http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/209624
work_keys_str_mv AT smeetsjulien promptgammaimagingwithaslitcameraforrealtimerangecontrolinparticletherapy
_version_ 1718628581676941312