Sources of contrast and acquisition methods in functional MRI of the human brain

<p align="justify">L'Imagerie fonctionnelle par Résonance Magnétique (IRMf) a connu un développement important depuis sa découverte au début des années 1990. Basée le plus souvent sur l'effet BOLD (Blood Oxygenation Level Dependent), cette technique permet d'obtenir de...

Full description

Bibliographic Details
Main Author: Denolin, Vincent
Other Authors: Metens, Thierry
Format: Doctoral Thesis
Language:fr
Published: Universite Libre de Bruxelles 2002
Subjects:
Online Access:http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/211408
id ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-211408
record_format oai_dc
collection NDLTD
language fr
format Doctoral Thesis
sources NDLTD
topic Sciences de l'ingénieur
Biologie
Brain -- Magnetic resonance imaging
Biomedical engineering
Imaging systems in medicine
Cerveau -- Imagerie par résonance magnétique
Génie biomédical
Imagerie médicale
Ingénierie biomédicale
Imagerie
Séquences
Cerveau
Résonance magnétique nucléaire
Modélisation
Techniques d imagerie et traitement d images
spellingShingle Sciences de l'ingénieur
Biologie
Brain -- Magnetic resonance imaging
Biomedical engineering
Imaging systems in medicine
Cerveau -- Imagerie par résonance magnétique
Génie biomédical
Imagerie médicale
Ingénierie biomédicale
Imagerie
Séquences
Cerveau
Résonance magnétique nucléaire
Modélisation
Techniques d imagerie et traitement d images
Denolin, Vincent
Sources of contrast and acquisition methods in functional MRI of the human brain
description <p align="justify">L'Imagerie fonctionnelle par Résonance Magnétique (IRMf) a connu un développement important depuis sa découverte au début des années 1990. Basée le plus souvent sur l'effet BOLD (Blood Oxygenation Level Dependent), cette technique permet d'obtenir de façon totalement non-invasive des cartes d'activation cérébrale, avec de meilleures résolutions spatiale et temporelle que les méthodes préexistantes telles que la tomographie par émission de positrons (TEP). Facilement praticable au moyen des imageurs par RMN disponible dans les hôpitaux, elle a mené à de nombreuses applications dans le domaine des neurosciences et de l'étude des pathologies cérébrales.</p><p><p align="justify">Il est maintenant bien établi que l'effet BOLD est dû à une augmentation de l'oxygénation du sang veineux dans les régions du cerveau où se produit l'activation neuronale, impliquant une diminution de la différence de susceptibilité magnétique entre le sang et les tissus environnants (la déoxyhémoglobine étant paramagnétique et l'oxyhémoglobine diamagnétique), et par conséquent un augmentation du signal si la méthode d'acquisition est sensible aux inhomogénéités de champ magnétique. Cependant, il reste encore de nombreuses inconnues quant aux mécanismes liant les variations d'oxygénation, de flux et de volume sanguin à l'augmentation de signal observée, et la dépendance du phénomène en des paramètres tels que l'intensité du champ, la résolution spatiale, et le type de séquence de RMN utilisée. La première partie de la thèse est donc consacrée à l'étude de l'effet BOLD, dans le cas particulier des contributions dues aux veines de drainage dans les séquences de type écho de gradient rendues sensibles au mouvement par l'ajout de gradients de champ. Le modèle développé montre que, contrairement au comportement suggéré par de précédentes publications, l'effet de ces gradients n'est pas une diminution monotone de la différence de signal lorsque l'intensité des gradients augmente. D'importantes oscillations sont produites par l'effet de phase dû au déplacement des spins du sang dans les gradients additionnels, et par la variation de cette phase suite à l'augmentation du flux sanguin. La validation expérimentale du modèle est réalisée au moyen de la séquence PRESTO (Principles of Echo-Shifting combined with a Train of Observations), c'est-à-dire une séquence en écho de gradient où des gradients supplémentaires permettent d'augmenter la sensibilité aux inhomogénéités de champ, et donc à l'effet BOLD. Un accord qualitatif avec la théorie est établi en montrant que la variation de signal observée peut augmenter lorsqu'on intensifie les gradients additionnels.</p><p><p align="justify">Un autre source de débat continuel dans le domaine de l'IRMf réside dans l'optimalisation des méthodes d'acquisition, au point de vue notamment de leur sensibilité à l'effet BOLD, leurs résolutions spatiale et temporelle, leur sensibilité à divers artefacts tels que la perte de signal dans les zones présentant des inhomogénéités de champ à grande échelle, et la contamination des cartes d'activation par les contributions des grosses veines, qui peuvent être distantes du lieu d'activation réel. Les séquences en écho de spin sont connues pour être moins sensibles à ces deux derniers problèmes, c'est pourquoi la deuxième partie de la thèse est consacrée à une nouvelle technique permettant de donner une pondération T2 plutôt que T2* aux images. Le principe de base de la méthode n'est pas neuf, puisqu'il s'agit de la « Préparation T2 » (T2prep), qui consiste à atténuer l'aimantation longitudinale différemment selon la valeur du temps de relaxation T2, mais il n’avait jamais été appliqué à l’IRMf. Ses avantages par rapport à d’autres méthodes hybrides T2 et T2* sont principalement le gain en résolution temporelle et en dissipation d’énergie électromagnétique dans les tissus. Le contraste généré par ces séquences est étudié au moyen de solutions stationnaires des équations de Bloch. Des prédictions sont faites quant au contraste BOLD, sur base de ces solutions stationnaires et d’une description simplifiée de l’effet BOLD en termes de variations de T2 et T2*. Une méthode est proposée pour rendre le signal constant au travers du train d’impulsions en faisant varier l’angle de bascule d’une impulsion à l’autre, ce qui permet de diminuer le flou dans les images. Des expériences in vitro montrent un accord quantitatif excellent avec les prédictions théoriques quant à l’intensité des signaux mesurés, aussi bien dans le cas de l’angle constant que pour la série d’angles variables. Des expériences d’activation du cortex visuel démontrent la faisabilité de l’IRMf au moyen de séquences T2prep, et confirment les prédictions théoriques quant à la variation de signal causée par l’activation.</p><p><p align="justify"> La troisième partie de la thèse constitue la suite logique des deux premières, puisqu’elle est consacrée à une extension du principe de déplacement d’écho (echo-shifting) aux séquences en écho de spin à l’état stationnaire, ce qui permet d’obtenir une pondération T2 et T2* importante tout en maintenant un temps de répétition court, et donc une bonne résolution temporelle. Une analyse théorique approfondie de la formation du signal dans de telles séquences est présentée. Elle est basée en partie sur la technique de résolution des équations de Bloch utilisée dans la deuxième partie, qui consiste à calculer l’aimantation d’état stationnaire en fonction des angles de précession dans le plan transverse, puis à intégrer sur les isochromats pour obtenir le signal résultant d’un voxel (volume element). Le problème est aussi envisagé sous l’angle des « trajectoires de cohérence », c’est-à-dire la subdivision du signal en composantes plus ou moins déphasées, par l’effet combiné des impulsions RF, des gradients appliqués et des inhomogénéités du champ magnétique principal. Cette approche permet d’interpréter l’intensité du signal dans les séquences à écho déplacé comme le résultat d’interférences destructives entre diverses composantes physiquement interprétables. Elle permet de comprendre comment la variation de la phase de l’impulsion d’excitation (RF-spoiling) élimine ces interférences. Des expériences in vitro montrent un accord quantitatif excellent avec les calculs théoriques, et la faisabilité de la méthode in vivo est établie. Il n’est pas encore possible de conclure quant à l’applicabilité de la nouvelle méthode dans le cadre de l’IRMf, mais l’approche théorique proposée a en tout cas permis de revoir en profondeur les mécanismes de formation du signal pour l’ensemble des méthodes à écho déplacé, puisque le cas de l’écho de gradient s’avère complètement similaire au cas de l’écho de spin.</p><p><p align="justify">La thèse évolue donc progressivement de la modélisation de l’effet BOLD vers la conception de séquences, permettant ainsi d’aborder deux aspects fondamentaux de la physique de l’IRMf.</p><p> === Doctorat en sciences appliquées === info:eu-repo/semantics/nonPublished
author2 Metens, Thierry
author_facet Metens, Thierry
Denolin, Vincent
author Denolin, Vincent
author_sort Denolin, Vincent
title Sources of contrast and acquisition methods in functional MRI of the human brain
title_short Sources of contrast and acquisition methods in functional MRI of the human brain
title_full Sources of contrast and acquisition methods in functional MRI of the human brain
title_fullStr Sources of contrast and acquisition methods in functional MRI of the human brain
title_full_unstemmed Sources of contrast and acquisition methods in functional MRI of the human brain
title_sort sources of contrast and acquisition methods in functional mri of the human brain
publisher Universite Libre de Bruxelles
publishDate 2002
url http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/211408
work_keys_str_mv AT denolinvincent sourcesofcontrastandacquisitionmethodsinfunctionalmriofthehumanbrain
_version_ 1718629160185757696
spelling ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-2114082018-04-11T17:35:28Z info:eu-repo/semantics/doctoralThesis info:ulb-repo/semantics/doctoralThesis info:ulb-repo/semantics/openurl/vlink-dissertation Sources of contrast and acquisition methods in functional MRI of the human brain Denolin, Vincent Metens, Thierry Van Ham, Philippe Baye, Daniel Jean Moonen, C. Bösiger, P. Segebarth, Christoph Bartik, Kristin Universite Libre de Bruxelles Université libre de Bruxelles, Faculté des sciences appliquées – Biosystèmes, Bruxelles 2002-10-08 fr <p align="justify">L'Imagerie fonctionnelle par Résonance Magnétique (IRMf) a connu un développement important depuis sa découverte au début des années 1990. Basée le plus souvent sur l'effet BOLD (Blood Oxygenation Level Dependent), cette technique permet d'obtenir de façon totalement non-invasive des cartes d'activation cérébrale, avec de meilleures résolutions spatiale et temporelle que les méthodes préexistantes telles que la tomographie par émission de positrons (TEP). Facilement praticable au moyen des imageurs par RMN disponible dans les hôpitaux, elle a mené à de nombreuses applications dans le domaine des neurosciences et de l'étude des pathologies cérébrales.</p><p><p align="justify">Il est maintenant bien établi que l'effet BOLD est dû à une augmentation de l'oxygénation du sang veineux dans les régions du cerveau où se produit l'activation neuronale, impliquant une diminution de la différence de susceptibilité magnétique entre le sang et les tissus environnants (la déoxyhémoglobine étant paramagnétique et l'oxyhémoglobine diamagnétique), et par conséquent un augmentation du signal si la méthode d'acquisition est sensible aux inhomogénéités de champ magnétique. Cependant, il reste encore de nombreuses inconnues quant aux mécanismes liant les variations d'oxygénation, de flux et de volume sanguin à l'augmentation de signal observée, et la dépendance du phénomène en des paramètres tels que l'intensité du champ, la résolution spatiale, et le type de séquence de RMN utilisée. La première partie de la thèse est donc consacrée à l'étude de l'effet BOLD, dans le cas particulier des contributions dues aux veines de drainage dans les séquences de type écho de gradient rendues sensibles au mouvement par l'ajout de gradients de champ. Le modèle développé montre que, contrairement au comportement suggéré par de précédentes publications, l'effet de ces gradients n'est pas une diminution monotone de la différence de signal lorsque l'intensité des gradients augmente. D'importantes oscillations sont produites par l'effet de phase dû au déplacement des spins du sang dans les gradients additionnels, et par la variation de cette phase suite à l'augmentation du flux sanguin. La validation expérimentale du modèle est réalisée au moyen de la séquence PRESTO (Principles of Echo-Shifting combined with a Train of Observations), c'est-à-dire une séquence en écho de gradient où des gradients supplémentaires permettent d'augmenter la sensibilité aux inhomogénéités de champ, et donc à l'effet BOLD. Un accord qualitatif avec la théorie est établi en montrant que la variation de signal observée peut augmenter lorsqu'on intensifie les gradients additionnels.</p><p><p align="justify">Un autre source de débat continuel dans le domaine de l'IRMf réside dans l'optimalisation des méthodes d'acquisition, au point de vue notamment de leur sensibilité à l'effet BOLD, leurs résolutions spatiale et temporelle, leur sensibilité à divers artefacts tels que la perte de signal dans les zones présentant des inhomogénéités de champ à grande échelle, et la contamination des cartes d'activation par les contributions des grosses veines, qui peuvent être distantes du lieu d'activation réel. Les séquences en écho de spin sont connues pour être moins sensibles à ces deux derniers problèmes, c'est pourquoi la deuxième partie de la thèse est consacrée à une nouvelle technique permettant de donner une pondération T2 plutôt que T2* aux images. Le principe de base de la méthode n'est pas neuf, puisqu'il s'agit de la « Préparation T2 » (T2prep), qui consiste à atténuer l'aimantation longitudinale différemment selon la valeur du temps de relaxation T2, mais il n’avait jamais été appliqué à l’IRMf. Ses avantages par rapport à d’autres méthodes hybrides T2 et T2* sont principalement le gain en résolution temporelle et en dissipation d’énergie électromagnétique dans les tissus. Le contraste généré par ces séquences est étudié au moyen de solutions stationnaires des équations de Bloch. Des prédictions sont faites quant au contraste BOLD, sur base de ces solutions stationnaires et d’une description simplifiée de l’effet BOLD en termes de variations de T2 et T2*. Une méthode est proposée pour rendre le signal constant au travers du train d’impulsions en faisant varier l’angle de bascule d’une impulsion à l’autre, ce qui permet de diminuer le flou dans les images. Des expériences in vitro montrent un accord quantitatif excellent avec les prédictions théoriques quant à l’intensité des signaux mesurés, aussi bien dans le cas de l’angle constant que pour la série d’angles variables. Des expériences d’activation du cortex visuel démontrent la faisabilité de l’IRMf au moyen de séquences T2prep, et confirment les prédictions théoriques quant à la variation de signal causée par l’activation.</p><p><p align="justify"> La troisième partie de la thèse constitue la suite logique des deux premières, puisqu’elle est consacrée à une extension du principe de déplacement d’écho (echo-shifting) aux séquences en écho de spin à l’état stationnaire, ce qui permet d’obtenir une pondération T2 et T2* importante tout en maintenant un temps de répétition court, et donc une bonne résolution temporelle. Une analyse théorique approfondie de la formation du signal dans de telles séquences est présentée. Elle est basée en partie sur la technique de résolution des équations de Bloch utilisée dans la deuxième partie, qui consiste à calculer l’aimantation d’état stationnaire en fonction des angles de précession dans le plan transverse, puis à intégrer sur les isochromats pour obtenir le signal résultant d’un voxel (volume element). Le problème est aussi envisagé sous l’angle des « trajectoires de cohérence », c’est-à-dire la subdivision du signal en composantes plus ou moins déphasées, par l’effet combiné des impulsions RF, des gradients appliqués et des inhomogénéités du champ magnétique principal. Cette approche permet d’interpréter l’intensité du signal dans les séquences à écho déplacé comme le résultat d’interférences destructives entre diverses composantes physiquement interprétables. Elle permet de comprendre comment la variation de la phase de l’impulsion d’excitation (RF-spoiling) élimine ces interférences. Des expériences in vitro montrent un accord quantitatif excellent avec les calculs théoriques, et la faisabilité de la méthode in vivo est établie. Il n’est pas encore possible de conclure quant à l’applicabilité de la nouvelle méthode dans le cadre de l’IRMf, mais l’approche théorique proposée a en tout cas permis de revoir en profondeur les mécanismes de formation du signal pour l’ensemble des méthodes à écho déplacé, puisque le cas de l’écho de gradient s’avère complètement similaire au cas de l’écho de spin.</p><p><p align="justify">La thèse évolue donc progressivement de la modélisation de l’effet BOLD vers la conception de séquences, permettant ainsi d’aborder deux aspects fondamentaux de la physique de l’IRMf.</p><p> Sciences de l'ingénieur Biologie Brain -- Magnetic resonance imaging Biomedical engineering Imaging systems in medicine Cerveau -- Imagerie par résonance magnétique Génie biomédical Imagerie médicale Ingénierie biomédicale Imagerie Séquences Cerveau Résonance magnétique nucléaire Modélisation Techniques d imagerie et traitement d images 1 v. Doctorat en sciences appliquées info:eu-repo/semantics/nonPublished local/bictel.ulb.ac.be:ULBetd-09302005-154004 local/ulbcat.ulb.ac.be:674588 http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/211408 No full-text files