Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contr...
Main Author: | |
---|---|
Format: | Doctoral Thesis |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/6148 http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-72531 https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-72531 https://opus.bibliothek.uni-wuerzburg.de/files/6148/Ehses_StrategiesForFastParameterQuantification.pdf |
id |
ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-6148 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
English |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
Kernspintomografie Messprozess Optimierung ddc:530 |
spellingShingle |
Kernspintomografie Messprozess Optimierung ddc:530 Ehses, Philipp Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
description |
Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant. === Die Magnetresonanztomographie (MRT) zeichnet sich als medizinisches Bildgebungsverfahren dadurch aus, dass sie ohne ionisierende Strahlung auskommt und nicht-invasiv einsetzbar ist. Ein weiterer wichtiger - wenn nicht der wichtigste - Grund für die weite und wachsende Verbreitung der MRT in der klinischen Praxis ist ihr interessantes und hoch-flexibles Kontrastverhalten, und damit die gute Darstellbarkeit biologischen Gewebes. Die Hauptnachteile der MRT sind die, verglichen mit z.B. Computer-Tomographie (CT), langen Messzeiten und die damit direkt verbundenen hohen Untersuchungskosten. Der erste Teil dieser Arbeit beschreibt Verbesserungen der IR TrueFISP Methode zur MR-Parameterbestimmung. IR TrueFISP ist eine schnelle Methode zur gleichzeitigen Quantifizierung der Protonendichte, der longitudinalen Relaxationszeit T1, sowie der transversalen Relaxationszeit T2. In Kapitel 2 dieser Arbeit wird eine Methode zur Beschleunigung der IR TrueFISP Quantifizierung vorgestellt, die es erlaubt einen kompletten Relaxometrie-Datensatz in unter 6 s pro Schicht aufzunehmen. Weiterhin werden in Kapitel 3 zwei allgemeine Fehlerquellen der IR TrueFISP Methode untersucht und Korrekturverfahren vorgestellt. Im zweiten Teil dieser Arbeit werden neuartige MR-Thermometrie Methoden vorgestellt, die sich besonders zur Untersuchung der MR-Sicherheit von medizinischen Implanten, insbesondere Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren (ICDs), eignen. Momentan sind in den allermeisten Fällen MRT Untersuchungen an Herzschrittmacher- und ICD-Patienten aufgrund der damit verbundenen Risiken kontraindiziert. Das dabei am schwierigste in den Griff zu bekommende und damit größte Risiko ist die mögliche Schädigung des Myokards, hervorgerufen durch die von den geschalteten HF-Feldern induzierten Ströme in den Schrittmacherelektroden. Um eine MR-sichere Elektrode und/oder sichere Messprotokole zu entwickeln ist es notwendig viele verschiedene Elektroden, Elektrodenpositionen und Messparameter-Einstellungen in einem körperähnlichen Gel-Phantom untersucht. Die bei der jeweiligen Messung auftretenden Erhitzungen werden dabei meist mit Hilfe fiberoptischer Thermometer an verschiedenen Positionen im Gel gemessen. Eine Alternative ist die Aufnahme einer globalen Karte der Temperaturerhöhung mit Hilfe der MR-Thermometrie. In dieser Arbeit wird eine Messmethode vorgestellt, die MR-Thermometrie mit HF induziertem Heizen kombiniert. Diese Methode wurde an einem Kupferdraht im Gelphantom validiert und mit fiberoptisch gemessenen Temperaturanstiegen verglichen. |
author |
Ehses, Philipp |
author_facet |
Ehses, Philipp |
author_sort |
Ehses, Philipp |
title |
Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
title_short |
Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
title_full |
Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
title_fullStr |
Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
title_full_unstemmed |
Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging |
title_sort |
development of new acquisition strategies for fast parameter quantification in magnetic resonance imaging |
publishDate |
2011 |
url |
https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/6148 http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-72531 https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-72531 https://opus.bibliothek.uni-wuerzburg.de/files/6148/Ehses_StrategiesForFastParameterQuantification.pdf |
work_keys_str_mv |
AT ehsesphilipp developmentofnewacquisitionstrategiesforfastparameterquantificationinmagneticresonanceimaging AT ehsesphilipp entwicklungneueraufnahmeverfahrenzurschnellenparameterbestimmungindermagnetresonanztomographie |
_version_ |
1719245761458208768 |
spelling |
ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-61482019-09-07T16:26:06Z Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging Entwicklung neuer Aufnahmeverfahren zur schnellen Parameterbestimmung in der Magnetresonanztomographie Ehses, Philipp Kernspintomografie Messprozess Optimierung ddc:530 Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant. Die Magnetresonanztomographie (MRT) zeichnet sich als medizinisches Bildgebungsverfahren dadurch aus, dass sie ohne ionisierende Strahlung auskommt und nicht-invasiv einsetzbar ist. Ein weiterer wichtiger - wenn nicht der wichtigste - Grund für die weite und wachsende Verbreitung der MRT in der klinischen Praxis ist ihr interessantes und hoch-flexibles Kontrastverhalten, und damit die gute Darstellbarkeit biologischen Gewebes. Die Hauptnachteile der MRT sind die, verglichen mit z.B. Computer-Tomographie (CT), langen Messzeiten und die damit direkt verbundenen hohen Untersuchungskosten. Der erste Teil dieser Arbeit beschreibt Verbesserungen der IR TrueFISP Methode zur MR-Parameterbestimmung. IR TrueFISP ist eine schnelle Methode zur gleichzeitigen Quantifizierung der Protonendichte, der longitudinalen Relaxationszeit T1, sowie der transversalen Relaxationszeit T2. In Kapitel 2 dieser Arbeit wird eine Methode zur Beschleunigung der IR TrueFISP Quantifizierung vorgestellt, die es erlaubt einen kompletten Relaxometrie-Datensatz in unter 6 s pro Schicht aufzunehmen. Weiterhin werden in Kapitel 3 zwei allgemeine Fehlerquellen der IR TrueFISP Methode untersucht und Korrekturverfahren vorgestellt. Im zweiten Teil dieser Arbeit werden neuartige MR-Thermometrie Methoden vorgestellt, die sich besonders zur Untersuchung der MR-Sicherheit von medizinischen Implanten, insbesondere Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren (ICDs), eignen. Momentan sind in den allermeisten Fällen MRT Untersuchungen an Herzschrittmacher- und ICD-Patienten aufgrund der damit verbundenen Risiken kontraindiziert. Das dabei am schwierigste in den Griff zu bekommende und damit größte Risiko ist die mögliche Schädigung des Myokards, hervorgerufen durch die von den geschalteten HF-Feldern induzierten Ströme in den Schrittmacherelektroden. Um eine MR-sichere Elektrode und/oder sichere Messprotokole zu entwickeln ist es notwendig viele verschiedene Elektroden, Elektrodenpositionen und Messparameter-Einstellungen in einem körperähnlichen Gel-Phantom untersucht. Die bei der jeweiligen Messung auftretenden Erhitzungen werden dabei meist mit Hilfe fiberoptischer Thermometer an verschiedenen Positionen im Gel gemessen. Eine Alternative ist die Aufnahme einer globalen Karte der Temperaturerhöhung mit Hilfe der MR-Thermometrie. In dieser Arbeit wird eine Messmethode vorgestellt, die MR-Thermometrie mit HF induziertem Heizen kombiniert. Diese Methode wurde an einem Kupferdraht im Gelphantom validiert und mit fiberoptisch gemessenen Temperaturanstiegen verglichen. 2011 doctoralthesis doc-type:doctoralThesis application/pdf https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/6148 urn:nbn:de:bvb:20-opus-72531 https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-72531 https://opus.bibliothek.uni-wuerzburg.de/files/6148/Ehses_StrategiesForFastParameterQuantification.pdf eng https://opus.bibliothek.uni-wuerzburg.de/doku/lic_ohne_pod.php info:eu-repo/semantics/openAccess |