Experimental study on the augmented Nusselt number of the endwall through a square-sectioned sharp-turn channel using novel heat exchanger

Aquiring higher thermal efficiency with minimum energy consumption is the continuous pursuit of heat exchanger design. This work aims to demonstrate a novel enhanced heat exchange approach for a two-pass heat exchanger surface using four forms of a novel heat exchanger (nHEX), such as high straight...

Full description

Bibliographic Details
Main Authors: Du, W. (Author), Luo, L. (Author), Sundén, B. (Author), Wang, S. (Author), Zhao, Z. (Author), Zhou, X. (Author)
Format: Article
Language:English
Published: Elsevier Ltd 2022
Subjects:
Online Access:View Fulltext in Publisher
LEADER 02287nam a2200241Ia 4500
001 10.1016-j.ijheatmasstransfer.2022.122920
008 220510s2022 CNT 000 0 und d
020 |a 00179310 (ISSN) 
245 1 0 |a Experimental study on the augmented Nusselt number of the endwall through a square-sectioned sharp-turn channel using novel heat exchanger 
260 0 |b Elsevier Ltd  |c 2022 
856 |z View Fulltext in Publisher  |u https://doi.org/10.1016/j.ijheatmasstransfer.2022.122920 
520 3 |a Aquiring higher thermal efficiency with minimum energy consumption is the continuous pursuit of heat exchanger design. This work aims to demonstrate a novel enhanced heat exchange approach for a two-pass heat exchanger surface using four forms of a novel heat exchanger (nHEX), such as high straight and low curved turbulators, etc. The nHEXs are arranged parallel and equally spaced on the internal endwall. A comparison between current design and conventionally turbulated endwalls of sharp-turn channels is presented. The results indicate that the heat transfer rate is greatly augmented by inserting an array of nHEXs compared to a smooth endwall channel. The strategically placed vortex generators can improve the lowest heat transfer region on the smooth endwall to achieve overall thermal enhancement and temperature uniformity. Among the studied geometries, higher height or straight forms of the nHEXs are prone to enhance endwall heat transfer. The high straight forms of the nHEXs provide the maximum improvement of the normalized Nusselt number and thermal enhancement factor in a sharp-turn channel, which are 32% and 18% higher than the corresponding values of the smooth endwall, respectively. This study proved the potential of an array of parallel nHEXs to provide endwall heat transfer enhancement in a sharp-turn channel with an acceptable pressure drop penalty. © 2022 
650 0 4 |a 180-deg sharp turn channel 
650 0 4 |a endwall Nusselt number 
650 0 4 |a liquid crystal thermography 
650 0 4 |a novel heat exchanger 
700 1 |a Du, W.  |e author 
700 1 |a Luo, L.  |e author 
700 1 |a Sundén, B.  |e author 
700 1 |a Wang, S.  |e author 
700 1 |a Zhao, Z.  |e author 
700 1 |a Zhou, X.  |e author 
773 |t International Journal of Heat and Mass Transfer