Comparing calculated and experimental activity and dose values obtained from image-based quantification of 90Y SPECT/CT Data

Purpose: Selective internal radiation therapy (SIRT) is a treatment for various kinds of liver tumours by injecting 90Y bearing microspheres into the liver vessels. To perform meaningful post-treatment dosimetry, quantitative imaging is performed. Methods: This work uses a Monte-Carlo based reconstr...

Full description

Bibliographic Details
Main Authors: Diemling, M. (Author), Haug, A. (Author), Lotter, K. (Author), Maringer, F.J (Author), Sohlberg, A. (Author), Wiedner, H. (Author)
Format: Article
Language:English
Published: Elsevier GmbH 2021
Subjects:
Online Access:View Fulltext in Publisher
LEADER 03674nam a2200673Ia 4500
001 10.1016-j.zemedi.2021.03.005
008 220427s2021 CNT 000 0 und d
020 |a 09393889 (ISSN) 
245 1 0 |a Comparing calculated and experimental activity and dose values obtained from image-based quantification of 90Y SPECT/CT Data 
260 0 |b Elsevier GmbH  |c 2021 
856 |z View Fulltext in Publisher  |u https://doi.org/10.1016/j.zemedi.2021.03.005 
520 3 |a Purpose: Selective internal radiation therapy (SIRT) is a treatment for various kinds of liver tumours by injecting 90Y bearing microspheres into the liver vessels. To perform meaningful post-treatment dosimetry, quantitative imaging is performed. Methods: This work uses a Monte-Carlo based reconstruction software with scatter and attenuation correction and collimator modelling that allows the quantification of 90Y bremsstrahlung SPECT/CT data. A dataset comprising 17 patients and measurements on a Jaszczak phantom, a NEMA IEC Body phantom and an anthropomorphic liver phantom are analysed and activities and dose values are acquired. These measured values are compared with applied activities and pre-treatment calculations, allowing to assess the quality of the SPECT reconstruction. A detailed uncertainty budget is presented, including uncertainties of the dose calibrator, the count rate, non-included interactions and other factors. Results: The applied method is validated by finding measurements repeatable within the given uncertainty, and it is shown the influence of various parameters on the reconstruction process is negligible. Furthermore, activities and doses measured in the phantoms show good agreement with calculated values, if they are corrected for partial volume effects. Conclusions: The strict observation of metrological requirements and the creation of an uncertainty budget increase the reliability and traceability of this novel approach to 90Y dosimetry. It gives an example of successful voxel-based dosimetry based on quantitative 90Y SPECT/CT image data. © 2021 
650 0 4 |a Activity concentration 
650 0 4 |a adult 
650 0 4 |a Article 
650 0 4 |a Austria 
650 0 4 |a clinical article 
650 0 4 |a dosimetry 
650 0 4 |a Dosimetry 
650 0 4 |a female 
650 0 4 |a human 
650 0 4 |a Humans 
650 0 4 |a image analysis 
650 0 4 |a image quality 
650 0 4 |a image reconstruction 
650 0 4 |a imaging phantom 
650 0 4 |a liver cell carcinoma 
650 0 4 |a Liver phantom 
650 0 4 |a macrosalb tc 99m 
650 0 4 |a male 
650 0 4 |a mathematical analysis 
650 0 4 |a Metrological quality 
650 0 4 |a Monte Carlo method 
650 0 4 |a Monte Carlo Method 
650 0 4 |a Phantoms, Imaging 
650 0 4 |a quantitative analysis 
650 0 4 |a radiation attenuation 
650 0 4 |a radiation scattering 
650 0 4 |a radiotherapy 
650 0 4 |a reliability 
650 0 4 |a reproducibility 
650 0 4 |a Reproducibility of Results 
650 0 4 |a selective internal radiation therapy 
650 0 4 |a single photon emission computed tomography 
650 0 4 |a SIRT 
650 0 4 |a SPECT quantification 
650 0 4 |a spectral domain optical coherence tomography 
650 0 4 |a Tomography, Emission-Computed, Single-Photon 
650 0 4 |a Tomography, X-Ray Computed 
650 0 4 |a uncertainty 
650 0 4 |a x-ray computed tomography 
650 0 4 |a yttrium 90 
700 1 |a Diemling, M.  |e author 
700 1 |a Haug, A.  |e author 
700 1 |a Lotter, K.  |e author 
700 1 |a Maringer, F.J.  |e author 
700 1 |a Sohlberg, A.  |e author 
700 1 |a Wiedner, H.  |e author 
773 |t Zeitschrift fur Medizinische Physik