Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach

A (PDMS)-coated stir bar was prepared for a glass jacket-free stir bar sorptive extraction (SBSE) configuration by adhesion technique for the extraction of triazine herbicides prior to quantification using a gas chromatography-flame ionization detector (GC-FID). A central composite design (CCD) was...

Full description

Bibliographic Details
Main Authors: Abdullah, M.P (Author), Abidin, N.A.Z (Author), Al-Qaim, F.F (Author), Khalik, W.M.A.W.M (Author), Othman, M.R (Author)
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences 2018
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 02059nam a2200253Ia 4500
001 10.17576-mjas-2018-2201-06
008 220120s2018 CNT 000 0 und d
020 |a 13942506 (ISSN) 
245 1 0 |a Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach 
260 0 |b Malaysian Society of Analytical Sciences  |c 2018 
490 1 |t Malaysian Journal of Analytical Sciences 
650 0 4 |a Central composite design 
650 0 4 |a Partition coefficient 
650 0 4 |a Stir bar sorptive extraction 
650 0 4 |a Triazine herbicides 
856 |z View Fulltext in Publisher  |u https://doi.org/10.17576/mjas-2018-2201-06 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85043345234&doi=10.17576%2fmjas-2018-2201-06&partnerID=40&md5=94badff0fdaaa62c29d3ee6d59ba998f 
520 3 |a A (PDMS)-coated stir bar was prepared for a glass jacket-free stir bar sorptive extraction (SBSE) configuration by adhesion technique for the extraction of triazine herbicides prior to quantification using a gas chromatography-flame ionization detector (GC-FID). A central composite design (CCD) was used in the optimization of extraction and desorption conditions. At optimum conditions, values of factors were set as pH 8.5, with no addition of NaCl, for 25 minutes of extraction time, and 24 minutes of desorption time. Under optimal experimental conditions, the proposed method has linear ranges at 0.1 – 100 µgL-1 with correlation of determination (R2), ranging from 0.9991 – 0.9995, respectively. The limit of detection (LODs) and limit of quantification (LOQs) of three triazines were found to be ranging from 0.015 – 0.023 µgL-1 and 0.047 – 0.060 µgL-1, respectively. © 2018, Malaysian Society of Analytical Sciences. All rights reserved. 
700 1 0 |a Abdullah, M.P.  |e author 
700 1 0 |a Abidin, N.A.Z.  |e author 
700 1 0 |a Al-Qaim, F.F.  |e author 
700 1 0 |a Khalik, W.M.A.W.M.  |e author 
700 1 0 |a Othman, M.R.  |e author 
773 |t Malaysian Journal of Analytical Sciences