Intrarater reliability of chest expansion using cloth tape measure technique

Objective: The Objective of this study was to determine the intrarater reliability of chest expansion at three different anatomical landmarks using a cloth tape measure among healthy peoples. Materials and Methods: 120 healthy male and female volunteers were evaluated on two occasions in different d...

Full description

Bibliographic Details
Main Authors: Dzulkifli, N.H (Author), Haron, R. (Author), Justine, M. (Author), Leonard Joseph, H. (Author), Mohan, V. (Author), Rathinam, C. (Author)
Format: Article
Language:English
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 02958nam a2200529Ia 4500
001 10.3329-bjms.v11i4.12602
008 220112s2012 CNT 000 0 und d
020 |a 22234721 (ISSN) 
245 1 0 |a Intrarater reliability of chest expansion using cloth tape measure technique 
856 |z View Fulltext in Publisher  |u https://doi.org/10.3329/bjms.v11i4.12602 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-84870315621&doi=10.3329%2fbjms.v11i4.12602&partnerID=40&md5=9382163e6f078e4c63079679bd135ace 
520 3 |a Objective: The Objective of this study was to determine the intrarater reliability of chest expansion at three different anatomical landmarks using a cloth tape measure among healthy peoples. Materials and Methods: 120 healthy male and female volunteers were evaluated on two occasions in different days. The measures consisted of chest expansion measurement at axilla, fourth intercostals and xiphoid levels. The measurements were taken in the standing position with the arms hanging sideways at all the three different anatomical landmarks. The test-retest reliability of the measurements was determined by intraclass correlation coefficient (ICC) and standard error of measurements (SEMs). Results: An acceptable reliability was determined by ICC values greater than than 0.85 and SEMs less than 5%. The mean age of the subjects was 21.93 years. ICC of all measures ranged between 0.95 to 0.97 and SEMs were 1.9%, 1.8%, 1.5% at the axillary, fourth intercostals and xiphoid level respectively. Conclusions: The findings of this study suggested that, the cloth tape measurement was reliable at all the three different anatomical landmarks of the chest wall. Therefore, this measurement technique could be used as an outcome measure for chest expansion in the management of cardiorespiratory conditions. 
650 0 4 |a adult 
650 0 4 |a analytical error 
650 0 4 |a anatomic landmark 
650 0 4 |a article 
650 0 4 |a axilla 
650 0 4 |a Axillary 
650 0 4 |a chest expansion 
650 0 4 |a Chest expansion 
650 0 4 |a cloth tape measurement 
650 0 4 |a correlation coefficient 
650 0 4 |a female 
650 0 4 |a fourth intercostal 
650 0 4 |a Fourth intercostals 
650 0 4 |a human 
650 0 4 |a human experiment 
650 0 4 |a intrarater reliability 
650 0 4 |a Intrarater reliability 
650 0 4 |a lung function 
650 0 4 |a male 
650 0 4 |a measurement 
650 0 4 |a normal human 
650 0 4 |a outcome assessment 
650 0 4 |a standard error of measurement 
650 0 4 |a standing 
650 0 4 |a sternum 
650 0 4 |a test retest reliability 
650 0 4 |a thorax 
650 0 4 |a Xiphoid 
700 1 0 |a Dzulkifli, N.H.  |e author 
700 1 0 |a Haron, R.  |e author 
700 1 0 |a Justine, M.  |e author 
700 1 0 |a Leonard Joseph, H.  |e author 
700 1 0 |a Mohan, V.  |e author 
700 1 0 |a Rathinam, C.  |e author 
773 |t Bangladesh Journal of Medical Science