In this research, we designed a rapid tricolour immunochromatographic test strip with double test lines (TS-DTL) and two-colour AuNP probes, which realised the simultaneous detection of tricaine mesylate (TMS) and malachite green (MG). Through a distinct tricolour system (red T1 line, blue T2 line a...

Full description

Bibliographic Details
Main Authors: Liu, W.-Y (Author), Lu, Y. (Author), Lu, Y.-K (Author), Xie, J. (Author), Xu, D. (Author)
Format: Article
Language:English
Published: MDPI 2022
Subjects:
Online Access:View Fulltext in Publisher
LEADER 02046nam a2200241Ia 4500
001 10.3390-bios12070456
008 220718s2022 CNT 000 0 und d
020 |a 20796374 (ISSN) 
245 1 0 |a A Rapid Tricolour Immunochromatographic Assay for Simultaneous Detection of Tricaine and Malachite Green 
260 0 |b MDPI  |c 2022 
856 |z View Fulltext in Publisher  |u https://doi.org/10.3390/bios12070456 
520 3 |a In this research, we designed a rapid tricolour immunochromatographic test strip with double test lines (TS-DTL) and two-colour AuNP probes, which realised the simultaneous detection of tricaine mesylate (TMS) and malachite green (MG). Through a distinct tricolour system (red T1 line, blue T2 line and purple C line), a visual identification of TMS (0.2 μg/mL) and MG (0.5 μg/mL) was quickly achieved on site, which improved the accuracy of naked eye observations. The LODs of TMS in aquaculture water, fish and shrimp were 11.0, 29.6 and 61.4 ng/mL, respectively. MG LODs were 47.0 ng/mL (aquaculture water), 82.8 ng/mL (fish) and 152.4 ng/mL (shrimp). The LOD of MG was close to the similar TS methods. However, visual detection of TMS could meet the re-quirements of the residue limit (1 μg/mL) of TMS in the USA, and the quantitative detection of TMS was over 16 times lower than the USA standard. The developed platform was rapid (~20 min, HPLC~3 h) and accurate, which was verified using a traditional HPLC method. The recovery rates ranged from 82.2% to 108.6% in three types of real samples, indicating a potential application in on-site fast screening or multiple detection for TMS and MG residues in aquatic products. © 2022 by the authors. Licensee MDPI, Basel, Switzerland. 
650 0 4 |a Au na-noparticles 
650 0 4 |a malachite green 
650 0 4 |a simultaneous detection 
650 0 4 |a tricaine mesylate 
650 0 4 |a tricolour test strip 
700 1 |a Liu, W.-Y.  |e author 
700 1 |a Lu, Y.  |e author 
700 1 |a Lu, Y.-K.  |e author 
700 1 |a Xie, J.  |e author 
700 1 |a Xu, D.  |e author 
773 |t Biosensors