Shaking table test on different positions of multiple tuned liquid damper

Earthquake can cause many problems to the structures, which lead to buildings collapse and may takes humans life. It is a nature’s hazard that cannot be stop. One of the effort is by introducing the damping system to the buildings where the energy of the system is slowly reduced until the vibration...

Full description

Bibliographic Details
Main Authors: Amin, N.M (Author), Hamid, N.A (Author), Ishak, I.S (Author)
Format: Article
Language:English
Published: Blue Eyes Intelligence Engineering and Sciences Publication 2019
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 01942nam a2200217Ia 4500
001 10.35940-ijeat.A3018.109119
008 220121s2019 CNT 000 0 und d
020 |a 22498958 (ISSN) 
245 1 0 |a Shaking table test on different positions of multiple tuned liquid damper 
260 0 |b Blue Eyes Intelligence Engineering and Sciences Publication  |c 2019 
650 0 4 |a Earthquake 
650 0 4 |a Multiple tuned liquid damper 
650 0 4 |a Shaking table 
650 0 4 |a Water tank 
856 |z View Fulltext in Publisher  |u https://doi.org/10.35940/ijeat.A3018.109119 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85074667867&doi=10.35940%2fijeat.A3018.109119&partnerID=40&md5=ed1765a72ffc1f5e39b85c977db29d0e 
520 3 |a Earthquake can cause many problems to the structures, which lead to buildings collapse and may takes humans life. It is a nature’s hazard that cannot be stop. One of the effort is by introducing the damping system to the buildings where the energy of the system is slowly reduced until the vibration of the system is totally eliminated and the system is brought to rest. Several techniques are available nowadays, however passive control system has advantage in term of cost compare to other systems. Multiple Tuned Liquid Damper (MTLD) is a passive system that traditionally made of several rigid tanks filled with water, usually placed on top of a building. The energy will dissipates through the sloshing and wave-breaking of the liquid once the earthquake strike the buildings. Shaking table tests are carried out on a two-bay, two-story steel frame with water tanks for different location. In this test, the displacement and acceleration for top and base are studied. © BEIESP. 
700 1 0 |a Amin, N.M.  |e author  
700 1 0 |a Hamid, N.A.  |e author  
700 1 0 |a Ishak, I.S.  |e author  
773 |t International Journal of Engineering and Advanced Technology  |x 22498958 (ISSN)  |g 9 1, 5863-5867