Surgical, clinical, and radiological outcomes of occipitocervical fusion using the plate–screw–rod system with allograft in craniocervical instability

Objective: We evaluated surgical, clinical, and radiological outcomes of posterior occipitocervical fusion (OCF) using plate–rod–screw construct supplemented with allograft in cases of occipitocervical instability. Study Design: This was a retrospective analysis of prospective collected data. Method...

Full description

Bibliographic Details
Main Authors: Mihir Upadhyaya, Sanyam Jain, Neilakuo Kire, Zahir Merchant, Vishal Kundnani, Ankit Patel
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Journal of Craniovertebral Junction and Spine
Subjects:
Online Access:http://www.jcvjs.com/article.asp?issn=0974-8237;year=2019;volume=10;issue=4;spage=216;epage=223;aulast=Upadhyaya