Sensitivity Analysis and Stray Capacitance of Helical Flux Compression Generator with Multi Layer Filamentary Conductor in Rectangular Cross-Section

This paper presents an approach to calculate the equivalent stray capacitance (SC) of n-turn of the helical flux compression generator (HFCG) coil with multi layer conductor wire filaments (MLCWF) in the form of rectangular cross-section. This approach is based on vespiary regular hexagonal (VRH) mo...

Full description

Bibliographic Details
Main Authors: M. E. Mosleh, M. R. Besmi
Format: Article
Language:English
Published: Iran University of Science and Technology 2012-03-01
Series:Iranian Journal of Electrical and Electronic Engineering
Subjects:
Online Access:http://ijeee.iust.ac.ir/browse.php?a_code=A-10-319-3&slc_lang=en&sid=1